CP1L

High Performing Programmable Controller with Embedded Ethernet

Categories: , ,

Description

• “CP1L-EM” and “CP1L-EL” have complete with a Ethernet port.

• Pulse output for two axes. Advanced power for high-precision positioning control.

• High-speed Counters. Single-phase for four axes.

• Six interrupt inputs are built in. Faster processing of instructions speeds up the entire system.

• Serial Communications. Two ports. Select Option Boards for either RS-232C or RS-485 communications.

• “CP1L-M” and “CP1L-L” have a peripheral USB port.

• The Structured Text (ST) Language. Makes math operations even easier.

• Can be used for the CP1W series Unit. The extendibility of it is preeminently good.

• LCD displays and settings. Enabled using Option Board.

 

Applicable standards

Refer to the OMRON website or ask your OMRON representative for the most recent applicable standards for each model.

CPU Units

Built-in Ethernet port

CPU Unit Specifications Model
CPU type Power
supply
Output method Inputs Out-
puts
CP1L-EM
CPU Units
with
40 Points
1916_lu_1_1
Memory capacity:
10K steps
High-speed counters:
100 kHz, 4 axes
Pulse outputs:
100 kHz, 2 axes
(Models with transistor
outputs only)
DC
power
supply
Relay output 24 16 CP1L-EM40DR-D
Transistor output
(sinking)
CP1L-EM40DT-D
Transistor output
(sourcing)
CP1L-EM40DT1-D
CP1L-EM
CPU Units
with
30 Points
1916_lu_1_2
Memory capacity:
10K steps
High-speed counters:
100 kHz, 4 axes
Pulse outputs:
100 kHz, 2 axes
(Models with transistor
outputs only)
DC
power
supply
Relay output 18 12 CP1L-EM30DR-D
Transistor output
(sinking)
CP1L-EM30DT-D
Transistor output
(sourcing)
CP1L-EM30DT1-D
CP1L-EL
CPU Units
with
20 Points
1916_lu_1_3
Memory capacity:
5K steps
High-speed counters:
100 kHz, 4 axes
Pulse outputs:
100 kHz, 2 axes
(Models with transistor
outputs only)
DC
power
supply
Relay output 12 8 CP1L-EL20DR-D
Transistor output
(sinking)
CP1L-EL20DT-D
Transistor output
(sourcing)
CP1L-EL20DT1-D

Built-in USB port

CPU Unit Specifications Model
CPU type Power
supply
Output method Inputs Outputs
CP1L-M CPU
Units with
60 Points
1916_lu_2_1
Memory capacity:
10K steps
High-speed counters:
100 kHz, 4 axes
Pulse outputs:
100 kHz, 2 axes
(Models with transistor
outputs only)
AC
power
supply
Relay output 36 24 CP1L-M60DR-A
Transistor output
(sinking)
CP1L-M60DT-A
DC
power
supply
Relay output CP1L-M60DR-D
Transistor output
(sinking)
CP1L-M60DT-D
Transistor output
(sourcing)
CP1L-M60DT1-D
CP1L-M CPU
Units with
40 Points
1916_lu_2_2
Memory capacity:
10K steps
High-speed counters:
100 kHz, 4 axes
Pulse outputs:
100 kHz, 2 axes
(Models with transistor
outputs only)
AC
power
supply
Relay output 24 16 CP1L-M40DR-A
Transistor output
(sinking)
CP1L-M40DT-A
DC
power
supply
Relay output CP1L-M40DR-D
Transistor output
(sinking)
CP1L-M40DT-D
Transistor output
(sourcing)
CP1L-M40DT1-D
CP1L-M CPU
Units with
30 Points
1916_lu_2_3
Memory capacity:
10K steps
High-speed counters:
100 kHz, 4 axes
Pulse outputs:
100 kHz, 2 axes
(Models with transistor
outputs only)
AC
power
supply
Relay output 18 12 CP1L-M30DR-A
Transistor output
(sinking)
CP1L-M30DT-A
DC
power
supply
Relay output CP1L-M30DR-D
Transistor output
(sinking)
CP1L-M30DT-D
Transistor output
(sourcing)
CP1L-M30DT1-D
CP1L-L CPU
Units with
20 Points
1916_lu_2_4
Memory capacity:
5K steps
High-speed counters:
100 kHz, 4 axes
Pulse outputs:
100 kHz, 2 axes
(Models with transistor
outputs only)
AC
power
supply
Relay output 12 8 CP1L-L20DR-A
Transistor output
(sinking)
CP1L-L20DT-A
DC
power
supply
Relay output CP1L-L20DR-D
Transistor output
(sinking)
CP1L-L20DT-D
Transistor output
(sourcing)
CP1L-L20DT1-D
CP1L-L CPU
Units with
14 Points
1916_lu_2_5
Memory capacity:
5K steps
High-speed counters:
100 kHz, 4 axes
Pulse outputs:
100 kHz, 2 axes
(Models with transistor
outputs only)
AC
power
supply
Relay output 8 6 CP1L-L14DR-A
Transistor output
(sinking)
CP1L-L14DT-A
DC
power
supply
Relay output CP1L-L14DR-D
Transistor output
(sinking)
CP1L-L14DT-D
Transistor output
(sourcing)
CP1L-L14DT1-D
CP1L-L CPU
Units with
10 Point
1916_lu_2_6
Memory capacity:
5K steps
High-speed counters:
100 kHz, 4 axes
Pulse outputs:
100 kHz, 2 axes
(Models with transistor
outputs only)
AC
power
supply
Relay output 6 4 CP1L-L10DR-A
Transistor output
(sinking)
CP1L-L10DT-A
DC
power
supply
Relay output CP1L-L10DR-D
Transistor output
(sinking)
CP1L-L10DT-D
Transistor output
(sourcing)
CP1L-L10DT1-D

Note: 1. Refer to “Models and Software Versions” about supported software.
2. Refer to “Option Unit Specifications” about supported Option Units.

Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
EtherNet/IPTM is the trademarks of ODVA.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.

Options for CPU Units

Name Specifications Model
RS-232C
Option Board
1916_lu_3_1 Can be mounted in either CPU Unit Option Board slot 1 or 2. *1 CP1W-CIF01
RS-422A/485
Option Board
1916_lu_3_2 CP1W-CIF11
RS-422A/485
(Isolated-type)
Option Board
1916_lu_3_3 CP1W-CIF12-V1
Ethernet
Option Board
1916_lu_3_4 Can be mounted in either CPU Unit Option Board slot 1 or 2.
*1 *2 *4
CP1W-CIF41
Analog Input
Option Board
1916_lu_3_5 Can be mounted in either CPU Unit Option Board slot 1 or 2. *3
2 analog inputs. 0-10V(Resolution:1/4000), 0-20mA (Resolution:
1/2000).
CP1W-ADB21
Analog Output
Option Board
1916_lu_3_6 Can be mounted in either CPU Unit Option Board slot 1 or 2. *3
2 analog outputs. 0-10V (Resolution:1/4000).
CP1W-DAB21V
Analog I/O
Option Board
1916_lu_3_7 Can be mounted in either CPU Unit Option Board slot 1 or 2. *3
2 analog inputs. 0-10V (Resolution:1/4000), 0-20mA (Resolution:
1/2000).
2 analog outputs. 0-10V (Resolution:1/4000).
CP1W-MAB221
LCD Option
Board
1916_lu_3_8 Can be mounted only in the CPU Unit Option Board slot 1. *1 CP1W-DAM01
Memory
Cassette
1916_lu_3_9 Can be used for backing up programs or auto-booting. CP1W-ME05M

*1. Cannot be used for the CP1L-L10.
*2. When using CP1W-CIF41 Ver.1.0, one Ethernet port can be added.
*3. CP1L-EM/EL only.
*4. Cannot be used for the CP1L-EM/EL.

Programming Devices

Name Specifications Model
Number
of
licenses
Media
FA
Integrated
Tool
Package
CX-One Lite
Version 4.[]
CX-One Lite is a subset of the complete CX-One
package that provides only the Support Software
required for micro PLC applications.
CX-One Lite runs on the following OS.
OS: Windows XP (Service Pack 3 or higher, 32-bit
version)/Windows Vista (32-bit/64-bit version)/
Windows 7 (32-bit/64-bit version)/Windows 8 (32-
bit/64-bit version)/Windows 8.1 (32-bit/64-bit
version)/Windows 10 (32-bit/64-bit version)

CX-One Lite Ver. 4.[] includes Micro PLC Edition
CX-Programmer Ver. 9.[].

1 license DVD CXONE-LT01D-V4
FA
Integrated
Tool
Package
CX-One
Ver.4.[]
CX-One is a package that integrates the Support
Software for OMRON PLCs and components. CX-
One runs on the following OS.
OS: Windows XP (Service Pack 3 or higher, 32-bit
version)/Windows Vista (32-bit/64-bit version)/
Windows 7 (32-bit/64-bit version)/Windows 8 (32-
bit/64-bit version)/Windows 8.1 (32-bit/64-bit
version)/Windows 10 (32-bit/64-bit version)

CX-One Ver. 4.[] includes CX-Programmer Ver. 9.[].

1 license
*1
DVD CXONE-AL01D-V4
Programming
Device
Connecting
Cable for
CP1W-CIF01
RS-232C
Option
Board *2
Connects Personal Computers, D-Sub 9-pin
(Length: 2.0 m)
For anti-static
connectors
XW2Z-200S-CV
Connects Personal Computers, D-Sub 9-pin
(Length: 5.0 m)
XW2Z-500S-CV
Connects Personal Computers, D-Sub 9-pin (Length: 2.0 m) XW2Z-200S-V
Connects Personal Computers, D-Sub 9-pin (Length: 5.0 m) XW2Z-500S-V
Note: 1. Refer to “Models and Software Versions” about supported software.
2. The CX-One and CX-One Lite cannot be simultaneously installed on the same computer.
*1. Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.
*2. Cannot be used with a peripheral USB port.
To connect to a personal computer via a peripheral USB port, use commercially-available USB cable (A or B type, male).

The following tables lists the Support Software that can be installed from CX-One

Support Software in CX-One CX-One Lite Ver.4.[] CX-One Ver.4.[]
Micro PLC Edition CX-Programmer Ver.9.[] Yes No
CX-Programmer Ver.9.[] No Yes
CX-Integrator Ver.2.[] Yes Yes
Switch Box Utility Ver.1.[] Yes Yes
CX-Protocol Ver.1.[] No Yes
CX-Simulator Ver.1.[] Yes Yes
CX-Position Ver.2.[] No Yes
CX-Motion-NCF Ver.1.[] No Yes
CX-Motion-MCH Ver.2.[] No Yes
CX-Motion Ver.2.[] No Yes
CX-Drive Ver.2.[] Yes Yes
CX-Process Tool Ver.5.[] No Yes
Faceplate Auto-Builder for NS Ver.3.[] No Yes
CX-Designer Ver.3.[] Yes Yes
NV-Designer Ver.1.[] Yes Yes
CX-Thermo Ver.4.[] Yes Yes
CX-ConfiguratorFDT Ver.1.[] Yes Yes
CX-FLnet Ver.1.[] No Yes
Network Configurator Ver.3.[] Yes Yes
CX-Server Ver.4.[] Yes Yes

Note: For details, refer to the CX-One Catalog (Cat. No: R134).

Models and Software Versions

The following versions of the CX-One, CX-Programmer are required.

Model CX-One CX-Programmer
CP1L-EM40[][]-[]
CP1L-EM30[][]-[]
CP1L-EL20[][]-[]
*1 Ver. 4.25 or higher Ver. 9.40 or higher
CP1L-M60[][]-[] *2 Ver. 2.11 or higher Ver. 7.20 or higher
CP1L-M40[][]-[]
CP1L-M30[][]-[]
CP1L-M20[][]-[]
CP1L-L14[][]-[]
*2 Ver. 2.10 or higher Ver. 7.10 or higher
CP1L-L10[][]-[] *2 Ver. 2.13 or higher Ver. 7.30 or higher
*1. Update The CX-Programmer version automatically from the website using CX-Programmer version 9.0 (included with
CX-One version 4.0).
*2. Update The CX-Programmer version automatically from the website using CX-Programmer version 7.0 (included with
CX-One version 2.0).

Expansion Units

Product
name
Inputs Outputs Output type Model
Input Unit 8 24 VDC Input CP1W-8ED
Output Units
1916_lu_7_1
8 Relay CP1W-8ER
Transistor (sinking) CP1W-8ET
Transistor (sourcing) CP1W-8ET1
16 Relay CP1W-16ER
Transistor (sinking) CP1W-16ET
Transistor (sourcing) CP1W-16ET1
32 Relay CP1W-32ER
Transistor (sinking) CP1W-32ET
Transistor (sourcing) CP1W-32ET1
I/O Units
1916_lu_7_2
12 8 Relay CP1W-20EDR1
Transistor (sinking) CP1W-20EDT
Transistor (sourcing) CP1W-20EDT1
24 16 Relay CP1W-40EDR
Transistor (sinking) CP1W-40EDT
Transistor (sourcing) CP1W-40EDT1
Analog
Input Unit
1916_lu_7_3
4CH Input range:
0 to 5 V, 1 to 5 V, 0 to 10 V, ±10 V,
0 to 20 mA, or 4 to 20 mA.
Resolution:
1/6000
CP1W-AD041
Resolution:
1/12000
CP1W-AD042
Analog
Output Unit
1916_lu_7_4
2CH Output range:
1 to 5 V, 0 to 10 V, ±10 V, 0 to 20 mA,
or 4 to 20 mA.
Resolution:
1/6000
CP1W-DA021
4CH Resolution:
1/6000
CP1W-DA041
Resolution:
1/12000
CP1W-DA042
Analog
I/O Unit
1916_lu_7_5
4CH 4CH Input range:
0 to 5 V, 1 to 5 V, 0 to 10 V, ±10 V,
0 to 20 mA, or 4 to 20 mA.
Output range:
1 to 5 V, 0 to 10 V, ±10 V, 0 to 20 mA,
or 4 to 20 mA.
Resolution:
1/12000
CP1W-MAD44
4CH 2CH Resolution:
1/12000
CP1W-MAD42
2CH 1CH Resolution:
1/6000
CP1W-MAD11
Temperature
Sensor Unit
1916_lu_7_6
2CH Sensor type: Thermocouple (J or K) CP1W-TS001
4CH Sensor type: Thermocouple (J or K) CP1W-TS002
2CH Sensor type: Platinum resistance thermometer
(Pt100 or JPt100)
CP1W-TS101
4CH Sensor type: Platinum resistance thermometer
(Pt100 or JPt100)
CP1W-TS102
4CH Sensor type: Thermocouple (J or K)
2 channels can be used as analog input.
Input range: 1 to 5 V, 0 to 10 V, 4-20 mA
Resolution:
1/12000
CP1W-TS003
12CH Sensor type: Thermocouple (J or K) CP1W-TS004
CompoBus/S
I/O Link Unit
1916_lu_7_7
8 8 CompoBus/S slave CP1W-SRT21

Note: CP1L (L Type) CPU Units with 10 points do not support Expansion Units.

I/O Connecting Cable

Name Specifications Model
I/O Connecting Cable 80 cm (for CP1W/CPM1A Expansion Units) CP1W-CN811

Note: An I/O Connecting Cable (approx. 6 cm) for horizontal connection is provided with CP1W Expansion Units.

Optional Products, Maintenance Products and DIN Track Accessories

Name Specifications Model
Battery Set For CPU Units (Use batteries within two years of manufacture.) CJ1W-BAT01
DIN Track Length: 0.5 m; Height: 7.3 mm PFP-50N
Length: 1 m; Height: 7.3 mm PFP-100N
Length: 1 m; Height: 16 mm PFP-100N2
End Plate A stopper to secure the Units on the DIN Track. PFP-M

Industrial Switching Hubs

Product
name
Appear-
ance
Specifications Accessories Current
con-
sump-
tion
(A)
Model
No.
of
ports
Failure
de-
tection
Industrial
Switching
Hubs
1916_lu_10_1 Quality of Service (QoS):
EtherNet/IP™ control
data priority
Failure detection:
Broadcast storm and
LSI error detection
10/100BASE-TX,
Auto-Negotiation
3 No Power supply
connector
0.22 W4S1-03B
1916_lu_10_2 5 No 0.22 W4S1-05B
5 Yes Power supply
connector
Connector for
informing error
0.22 W4S1-05C

 

General Specifications

Type AC power supply models DC power supply models
Model CP1L-[][][]-A CP1L-[][][]-D
Power supply 100 to 240 VAC 50/60 Hz 24 VDC
Operating voltage
range
85 to 264 VAC 20.4 to 26.4 VDC
Power consumption 50 VA max. (CP1L-M60/-M40/-M30[][]-A)
30 VA max. (CP1L-L20/-L14/-L10[][]-A)
20 W max. (CP1L-EM40/-EM30/-M60/-M40/
-M30[][]-D)
13 W max. (CP1L-EL20/-L20/-L14/
-L10[][]-D)
Inrush current * 100 to 120 VAC inputs:
20 A max. (for cold start at room
temperature)
8 ms max.
200 to 240 VAC inputs:
40 A max. (for cold start at room
temperature),
8 ms max.
30 A max. (for cold start at room
temperature)
20 ms max.
External power supply 300 mA at 24 VDC (CP1L-M60/-M40/
-M30[][]-A)
200 mA at 24 VDC (CP1L-L20/-L14/
-L10[][]-A)
None
Insulation resistance 20 MΩ min. (at 500 VDC) between the
external AC terminals and GR terminals
No insulation between primary and secondary
for DC power supply
Dielectric strength 2,300 VAC at 50/60 Hz for 1 min between
the external AC and GR terminals, leakage
current: 5 mA max.
No insulation between primary and secondary
for DC power supply
Noise immunity Conforms to IEC 61000-4-4. 2 kV (power supply line)
Vibration resistance CP1L-L/M:
Conforms to JIS C60068-2-6. 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration:
9.8 m/s2 in X, Y, and Z directions for 80 minutes each. Sweep time: 8 minutes × 10 sweeps
= total time of 80 minutes)
CP1L-EL/EM:
5 to 8.4 Hz, 3.5 mm amplitude, 8.4 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions
for 100 minutes each (time coefficient of 10 minutes × coefficient factor of 10 = total time
of 100 minutes)
Shock resistance Conforms to JIS C60068-2-27. 147 m/s2 three times each in X, Y, and Z directions
Ambient operating
temperature
0 to 55°C
Ambient humidity 10% to 90% (with no condensation)
Ambient operating
environment
No corrosive gas
Ambient storage
temperature
-20 to 75°C (Excluding battery.)
Power holding time 10 ms min. 2 ms min.

* The above values are for a cold start at room temperature for an AC power supply, and for a cold start for a DC power
supply.
• A thermistor (with low-temperature current suppression characteristics) is used in the inrush current control circuitry
for the AC power supply. The thermistor will not be sufficiently cooled if the ambient temperature is high or if a hot
start is performed when the power supply has been OFF for only a short time. In those cases the inrush current
values may be higher (as much as two times higher) than those shown above. Always allow for this when selecting
fuses and breakers for external circuits.
• A capacitor charge-type delay circuit is used in the inrush current control circuitry for the DC power supply. The
capacitor will not be charged if a hot start is performed when the power supply has been OFF for only a short time,
so in those cases the inrush current values may be higher (as much as two times higher) than those shown above.

Performance Specifications

CP1L CPU Unit (EM/EL Type)

Type CP1L-EM40 (40 points) CP1L-EM30 (30 points) CP1L-EL20 (20 points)
Models CP1L-EM40D[]-[] CP1L-EM30D[]-[] CP1L-EL20D[]-[]
Control method Stored program method
I/O control method Cyclic scan with immediate refreshing
Program language Ladder diagram
Function blocks Maximum number of function block definitions: 128 Maximum number of instances: 256
Languages usable in function block definitions: Ladder diagrams, structured text (ST)
Instruction length 1 to 7 steps per instruction
Instructions Approx. 500 (function codes: 3 digits)
Instruction execution time Basic instructions: 0.55 μs min. Special instructions: 4.1 μs min.
Common processing time 0.4ms
Program capacity 10K steps 5K steps
FB program
memory
10K steps
Number of tasks 288 (32 cyclic tasks and 256 interrupt tasks)
Scheduled
interrupt tasks
1 (interrupt task No. 2, fixed)
Input interrupt
tasks
6 (interrupt task No. 140 to 145, fixed)
(High-speed counter interrupts and interrupt tasks specified by external interrupts can
also be executed.)
Maximum subroutine
number
256
Maximum jump number 256
I/O
areas
Input Area 1,600 bits (100 words) CIO 0 to CIO 99
Built-in Input
Area
24 bits: CIO 0.00 to CIO
0.11 and CIO 1.00 to CIO
1.11
18 bits: CIO 0.00 to CIO
0.11 and CIO 1.00 to CIO
1.05
12 bits: CIO 0.00 to CIO 0.11
Output Area 1,600 bits (100 words) CIO 100 to CIO 199
Built-in Output
Area
16 bits: CIO 100.00 to CIO
100.07 and CIO 101.00 to
CIO 101.07
12 bits: CIO 100.00 to CIO
100.07 and CIO 101.00 to
CIO 101.03
8 bits: CIO 100.00 to CIO
100.07
1:1 Link Area 256 bits (16 words): CIO 3000.00 to CIO 3015.15 (CIO 3000 to CIO 3015)
Serial PLC Link
Area
1,440 bits (90 words): CIO 3100.00 to CIO 3189.15 (CIO 3100 to CIO 3189)
Work bits 4,800 bits (300 words): CIO 1200.00 to CIO 1499.15 (words CIO 1200 to CIO 1499)
6,400 bits (400 words): CIO 1500.00 to CIO 1899.15 (words CIO 1500 to CIO 1899)
15,360 bits (960 words): CIO 2000.00 to CIO 2959.15 (words CIO 2000 to CIO 2959)
9,600 bits (600 words): CIO 3200.00 to CIO 3799.15 (words CIO 3200 to CIO 3799)
37,504 bits (2,344 words): CIO 3800.00 to CIO 6143.15 (words CIO 3800 to CIO 6143)
TR Area 16 bits: TR0 to TR15
Holding Area 8,192 bits (512 words): H0.00 to H511.15 (H0 to H511)
AR Area Read-only (Write-prohibited): 7168 bits (448 words): A0.00 to A447.15 (A0 to A447)
Read/Write: 8192 bits (512 words): A448.00 to A959.15 (A448 to A959)
Timers 4,096 timer numbers: T0 to T4095
Counters 4,096 counter numbers: C0 to C4095
DM Area 32 Kwords: D0 to D32767 10 Kwords: D0 to D9999,
D32000 to D32767
Data Register Area 16 registers (16 bits): DR0 to DR15
Index Register Area 16 registers (32 bits): IR0 to IR15
Task Flag Area 32 flags (32 bits): TK0000 to TK0031
Trace Memory 4,000 words (500 samples for the trace data maximum of 31 bits and 6 words.)
Memory Cassette A special Memory Cassette (CP1W-ME05M) can be mounted.
Note: Can be used for program backups and auto-booting.
Clock function Supported. Accuracy (monthly deviation): -4.5 min to -0.5 min (ambient temperature:
55°C),
-2.0 min to +2.0 min (ambient temperature: 25°C), -2.5 min to +1.5 min (ambient
temperature: 0°C)
Communications functions Built-in Ethernet Port (Connecting Support Software, Message Communications,
Socket Service)
A maximum of two Serial Communications Option
Boards can be mounted.
A maximum of one Serial
Communications Option
Board can be mounted.
Memory backup Flash memory: User programs, parameters (such as the PLC Setup), comment data,
and the entire DM Area can be saved to flash memory as initial values.
Battery backup: The Holding Area, DM Area, and counter values (flags, PV) are backed
up by a battery.
Battery service life Service life expectancy is 5 years at 25°C, less at higher temperatures. (From 0.75
to 5 years depending on model, power supply rate, and ambient temperature.)
Built-in input terminals 40 (24 inputs, 16 outputs) 30 (18 inputs, 12 outputs) 20 (12 inputs, 8 outputs)
Number of connectable
Expansion Units and
Expansion I/O Units
CP-series Expansion Unit and Expansion I/O Units:
3 max.
CP-series Expansion Units
and Expansion I/O Units:
1 max.
Max. number of I/O points 160 (40 built in + 40 per
Expansion (I/O) Unit x 3
Units)
150 (30 built in + 40 per
Expansion (I/O) Unit x 3
Units)
60 (20 built in + 40 per
Expansion (I/O) Unit x 1
Unit)
Interrupt inputs 6 inputs (Response time: 0.3 ms)
Interrupt inputs counter
mode
6 inputs (Response frequency: 5 kHz max. for all interrupt inputs), 16 bits Up or down
counters
Quick-response inputs 6 points (Min. input pulse width: 50 μs max.)
Scheduled interrupts 1
High-speed counters 4 inputs/2 axes (24 VDC)
Differential phases (4x), 50 kHz
Single-phase (pulse plus direction, up/down, increment), 100 kHz
Value range: 32 bits, Linear mode or ring mode
Interrupts: Target value comparison or range comparison
Pulse
outputs
(models
with
transistor
outputs
only)
Pulse outputs Trapezoidal or S-curve acceleration and deceleration (Duty ratio: 50% fixed)
2 outputs, 1 Hz to 100 kHz (CCW/CW or pulse plus direction)
PWM outputs Duty ratio: 0.0% to 100.0% (specified in increments of 0.1% or 1%)
2 outputs, 0.1 to 6553.5 Hz or 1 to 32,800 Hz
(Accuracy: +1%/0% at 0.1 Hz to 10,000 Hz and +5%/0% at 10,000 Hz to 32,800 Hz)
Analog input 2 input (Resolution: 1/1000, Input range: 0 to 10 V). Not isolated.

CP1L CPU Unit (M/L Type)

Type CP1L-M60
(60 points)
CP1L-M40
(40 points)
CP1L-M30
(30 points)
CP1L-L20
(20 points)
CP1L-L14
(14 points)
CP1L-L10
(10 points)
Models CP1L-
M60[][]-[]
CP1L-
M40[][]-[]
CP1L-
M30[][]-[]
CP1L-
L20[][]-[]
CP1L-
L14[][]-[]
CP1L-
L10[][]-[]
Control method Stored program method
I/O control method Cyclic scan with immediate refreshing
Program language Ladder diagram
Function blocks Maximum number of function block definitions: 128 Maximum number of instances: 256
Languages usable in function block definitions: Ladder diagrams, structured text (ST)
Instruction length 1 to 7 steps per instruction
Instructions Approx. 500 (function codes: 3 digits)
Instruction execution
time
Basic instructions: 0.55 μs min. Special instructions: 4.1 μs min.
Common processing
time
0.4 ms
Program capacity 10K steps 5K steps
Number of tasks 288 (32 cyclic tasks and 256 interrupt tasks)
Scheduled
interrupt
tasks
1 (interrupt task No. 2, fixed)
Input
interrupt
tasks
6 (interrupt task No. 140 to 145, fixed) 4 (interrupt
task No. 140
to 143, fixed)
2 (interrupt
task No. 140
to 141, fixed)
(Interrupt tasks can also be specified and executed for high-speed counter interrupts and
executed.)
Maximum subroutine
number
256
Maximum jump number 256
I/O
areas
Input Area 1,600 bits (100 words) CIO 0 to CIO 99
Built-in
Input Area
36 bits: CIO
0.00 to CIO
0.11 and CIO
1.00 to CIO
1.11 and CIO
2.00 to CIO
2.11
24 bits: CIO
0.00 to CIO
0.11 and CIO
1.00 to CIO
1.11
18 bits: CIO
0.00 to CIO
0.11 and CIO
1.00 to CIO
1.05
12 bits: CIO
0.00 to CIO
0.11
8 bits: CIO
0.00 to CIO
0.07
6 bits: CIO
0.00 to CIO
0.05
Output Area 1,600 bits (100 words) CIO 100 to CIO 199
Built-in
Output
Area
24 bits: CIO
100.00 to CIO
100.07 and
CIO 101.00 to
CIO 101.07
and CIO
102.00 to CIO
102.07
16 bits: CIO
100.00 to CIO
100.07 and
CIO 101.00 to
CIO 101.07
12 bits: CIO
100.00 to CIO
100.07 and
CIO 101.00 to
CIO 100.03
8 bits: CIO
100.00 to
CIO 100.07
6 bits: CIO
100.00 to
CIO 100.05
4 bits: CIO
100.00 to
CIO 100.03
1:1 Link
Area
1,024 bits (64 words): CIO 3000.00 to CIO 3063.15 (CIO 3000 to CIO 3063)
Serial PLC
Link Area
1,440 bits (90 words): CIO 3100.00 to CIO 3189.15 (CIO 3100 to CIO 3189)
Work bits 8,192 bits (512 words): W000.00 to W511.15 (W0 to W511)
CIO Area: 37,504 bits (2,344 words): CIO 3800.00 to CIO 6143.15 (CIO 3800 to CIO 6143)
TR Area 16 bits: TR0 to TR15
Holding Area 8,192 bits (512 words): H0.00 to H511.15 (H0 to H511)
AR Area Read-only (Write-prohibited): 7168 bits (448 words): A0.00 to A447.15 (A0 to A447)
Read/Write: 8192 bits (512 words): A448.00 to A959.15 (A448 to A959)
Timers 4,096 timer numbers: T0 to T4095
Counters 4,096 counter numbers: C0 to C4095
DM Area 32 Kwords: D0 to D32767 10 Kwords: D0 to D9999, D32000 to
D32767
Data Register Area 16 registers (16 bits): DR0 to DR15
Index Register Area 16 registers (32 bits): IR0 to IR15
Task Flag Area 32 flags (32 bits): TK0000 to TK0031
Trace Memory 4,000 words (500 samples for the trace data maximum of 31 bits and 6 words.)
Memory Cassette A special Memory Cassette (CP1W-ME05M) can be mounted. Note: Can be used for program
backups and auto-booting.
Clock function Supported. Accuracy (monthly deviation): -4.5 min to -0.5 min (ambient temperature: 55°C),
-2.0 min to +2.0 min (ambient temperature: 25°C),
-2.5 min to +1.5 min (ambient temperature: 0°C)
Communications
functions
One built-in peripheral port (USB 1.1): For connecting Support Software only.
A maximum of two Serial Communications
Option Boards can be mounted.
A maximum of one Serial
Communications Option
Board can be mounted.
Not
supported.
A maximum of two Ethernet Option Board
can be mounted.
When using CP1W-CIF41 Ver.1.0, one
Ethernet Option Board can be mounted.
A maximum of one
Ethernet Option Board
can be mounted.
Not
supported.
Memory backup Flash memory: User programs, parameters (such as the PLC Setup), comment data, and the
entire DM Area can be saved to flash memory as initial values.
Battery backup: The Holding Area, DM Area, and counter values (flags, PV) are backed up by a
battery.
Battery service life Service life expectancy is 5 years at 25°C, less at higher temperatures. (From 0.75 to 5 years
depending on model, power supply rate, and ambient temperature.)
Built-in input
terminals
60 (36
inputs,
24 outputs)
40 (24
inputs,
16 outputs)
30 (18
inputs,
12 outputs)
20 (12
inputs,
8 outputs)
14 (8
inputs,
6 outputs)
10 (6
inputs,
4 outputs)
Number of
connectable
Expansion Units and
Expansion I/O Units
CP-series Expansion Unit and Expansion
I/O Units: 3 max.
CP-series Expansion Units
and Expansion I/O Units: 1 max.
Not
supported.
Max. number of I/O
points
180 (60 built
in + 40 per
Expansion
(I/O) Unit
× 3 Units)
160 (40 built
in + 40 per
Expansion
(I/O) Unit
× 3 Units)
150 (30 built
in + 40 per
Expansion
(I/O) Unit
× 3 Units)
60 (20 built
in + 40 per
Expansion
(I/O) Unit
× 1 Unit)
54 (14 built
in + 40 per
Expansion
(I/O) Unit
× 1 Unit)
10 (10 built
in)
Interrupt inputs 6 inputs (Response time: 0.3 ms) 4 inputs
(Response
time: 0.3 ms)
2 inputs
(Response
time: 0.3 ms)
Interrupt inputs
counter mode
6 inputs (Response frequency: 5 kHz max. for all interrupt
inputs), 16 bits
Up or down counters
4 inputs
(Response
frequency:
5 kHz max.
for all
interrupt
inputs), 16
bits Up or
down
counters
2 inputs
(Response
frequency:
5 kHz max.
for all
interrupt
inputs), 16
bits Up or
down
counters
Quick-response inputs 6 points (Min. input pulse width: 50 μs max.) 4 points (Min.
input pulse
width: 50 μs
max.)
2 points (Min.
input pulse
width: 50 μs
max.)
Scheduled interrupts 1
High-speed counters 4 inputs/2 axes (24 VDC):
Differential phases (4x), 50 kHz
Single-phase (pulse plus direction, up/down, increment), 100 kHz
Value range: 32 bits, Linear mode or ring mode
Interrupts: Target value comparison or range comparison
Pulse
outputs
(models
with
transistor
outputs
only)
Pulse
outputs
Trapezoidal or S-curve acceleration and deceleration (Duty ratio: 50% fixed)
2 outputs, 1 Hz to 100 kHz (CCW/CW or pulse plus direction)
PWM
outputs
Duty ratio: 0.0% to 100.0% (specified in increments of 0.1% or 1%)
2 outputs, 0.1 to 6553.5 Hz or 1 to 32,800 Hz (Accuracy: +1%/0% at 0.1 Hz to 10,000 Hz and
+5%/0% at 10,000 Hz to 32,800 Hz)
Analog control 1 (Setting range: 0 to 255)
Analog input 1 input (Resolution: 1/256, Input range: 0 to 10 V). Not isolated.

 

(Unit: mm)

CPU Units

CP1L-EM CPU Units with 40 Points

CP1L Dimensions 2

CP1L-EM CPU Units with 30 Points

CP1L Dimensions 3

CP1L-EL CPU Units with 20 Points

CP1L Dimensions 4

CP1L CPU Units with 60 I/O Points

CP1L Dimensions 5

CP1L CPU Units with 40 I/O Points

CP1L Dimensions 6

CP1L CPU Units with 30 I/O Points

CP1L Dimensions 7

CP1L CPU Units with 14 or 20 I/O Points

CP1L Dimensions 8

CP1L CPU Units with 10 I/O Points

CP1L Dimensions 9

Expansion Units and Expansion I/O Units

CP1W-20ED[][], CP1W-16[][],
CP1W-AD04[], CP1W-DA021/04[],
CP1W-MAD[][], CP1W-TS[][]1/[][]2/[][]3

CP1L Dimensions 11

CP1W-8E[][]
CP1W-SRT21

CP1L Dimensions 12

CP1W-40ED[]
CP1W-32E[][]
CP1W-TS004

CP1L Dimensions 13
CP1L Dimensions 14
Catalog Name
Catalog Number
[size]
Last Update
 CP1L Data Sheet P081-E1-03
[3487KB]
Dec 03, 2018
 CP1 Catalog P082-E1-05
[5577KB]
Jan 05, 2018
 New Functions Added to CS/CJ/CP Series Catalog P097-E1-01
[1267KB]
Sep 28, 2015
 FA Controller Catalog P090-E1-07
[18214KB]
Aug 20, 2018

Reviews

There are no reviews yet.

Be the first to review “CP1L”

Your email address will not be published. Required fields are marked *



Exclusive products

Special category of products