CJ1W-CLK

New Controller Link Units, Now with 4,000 Send Words

Description

• Large-capacity data links are easily achieved without programming simply by setting data link tables.

• Up to 20,000 *1 send/receive words can be set per node for Units (up to 62,000 words for Boards).

• Data links can be performed with up to 4,000 *2 words per node while ensuring data concurrency.

• User-set data link tables can be changed while data links are operating. *3

• Errors for the entire system can be monitored by using error diagnosis support software and a variety of status flags.

*1. Supported for unit version 1.2 or later.
*2. CJ1W-CLK23 and 3G8F7-CLK[]3 are supported.
*3. Supported for CJ1W-CLK23, 3G8F7-CLK[]3, and models ending with “-V1”.

 

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

Controller Link Units

Unit
clas-
sifica-
tion
Product
name
Specifications No. of
unit
numbers
allocated
Current
consumption
(A)
Model Stand-
ards
Communi-
cations
cable
Communi-
cations
type
Duplex
support
Max. Units
mountable
per CPU
Unit
5 V
DC
24 V
DC
CJ1
CPU
Bus
Unit
Controller
Link Unit

Wired shielded
twisted-pair
cable *
Data links
and message
service
No 8 1 0.35 CJ1W-CLK23 UC1, N,
L, CE
Note: This unit cannot be used with the Machine Automation Controller NJ-series.
* Use the following special cable for shielded, twisted-pair cable.
• ESVC0.5×2C-13262 (Bando Electric Wire: Japanese Company)
• ESNC0.5×2C-99-087B (JMACS Japan Co., Ltd.: Japanese Company)
• ESPC 1P×0.5mm2 (Nagaoka Electric Wire Co.,Ltd.: Japanese Company)
• Li2Y-FCY2×0.56qmm (Kromberg & Schubert, Komtec Department: German Company)
• 1×2×AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)
• #9207 (Belden: US Company)

Accessories

There is no accessory for the CJ series Controller Link Unit.

Controller Link Support Boards

Product name Specifications Accessories Model Standards
Communications
cable
Communications
type
Controller Link
Support Board
for PCI Bus

Wired shielded
twisted-pair cable
Data links and
message service
CD-ROM x 1 *
INSTALLATION GUIDE (W467) x 1
Communications connector x 1
3G8F7-CLK23-E CE
* The CD-ROM contains the following software.
• Controller Link (PCI) Driver
• FinsGateway Version 2003 (PCI-CLK Edition)
• FinsGateway Version 3 (PCI-CLK Edition)
• Setup Diagnostic Utility
• C Library

Repeater Units

Name Specifications Model Standards
Controller Link
Repeater Unit

Wire-to-Wire Model CS1W-RPT01 UC1, CE
Wire-to-Optical (H-PCF) Model *1 CS1W-RPT02
Wire-to-Optical (GI) Model *2 CS1W-RPT03
Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks, 62-node configurations, and converting part of the network to optical cable.
*1. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF
optical fiber cable with connector.
*2. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).

Relay Terminal Block

Name Specifications Model Standards
Relay Terminal Block for
Wired Controller Link Units

Used for Wired Controller Link Units (set of 5) CJ1W-TB101

Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in advance on the Unit in a Wired Controller Link network. Relay Terminal Blocks cannot be used on Controller Link Support Boards.

H-PCF Cables and Optical Connectors

Name Application/construction Specifications Model Standards
Optical Fiber Cables Controller
Link,
SYSMAC
LINK,
SYSBUS

1. Optical fiber
single-core cord
2. Tension member
(plastic-sheathed wire)
3. Filler (plastic)
4. Filler surrounding
signal wires
(plastic, yarn, or fiber)
5. Holding tape (plastic)
6. Heat-resistant PV
sheath
Two-core
optical
cable with
tension
member
Black 10 m S3200-HCCB101
Black 50 m S3200-HCCB501
Black 100 m S3200-HCCB102
Black 500 m S3200-HCCB502
Black 1000 m S3200-HCCB103
Orange 10 m S3200-HCCO101
Orange 50 m S3200-HCCO501
Orange 100 m S3200-HCCO102
Orange 500 m S3200-HCCO502
Orange 1000 m S3200-HCCO103
Optical
Connectors
(Crimp-cut)
CS1W-RPT02 Half lock S3200-COCF2571
Full lock S3200-COCF2071

H-PCF Optical Fiber Cables with Connectors (Black Composite Cables with Two-Optical Lines and Two Power Supply Lines)

Application Appearance Model Standards
Controller Link,
SYSMAC LINK
S3200-CN[][][]-20-20
S3200-CN[][][]-20-25
S3200-CN[][][]-25-25

Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished.

Cable Length

The following cable lengths are available: 2 m, 5 m, 15 m, 20 m. For lengths of 21 m or more, contact your OMRON sales representative.

Model Numbers

CJ1W-CLK Lineup 15

Optical Connector Assembly Tool

Name Applicable Unit Model Manufacturer Standards
Optical Fiber
Assembly Tool *
This tool is used on site for mounting crimp-cut connectors
and hard plastic-clad silica optical fiber for optical transmission
systems of SYSMAC C-series SYSBUS, SYSMAC LINK, and
Controller Link.
CAK-0057 Sumitomo Electric
Industries, Ltd.
* There is a risk of quality problems when using cables assembled by typical users, so we recommend purchasing
cables with preattached connectors or having a qualified technician assemble the cables.

Communications Specifications

Items Specifications
Model CJ1W-CLK23
3G8F7-CLK23-E
CJ1W-CLK21-V1 *1
3G8F7-CLK21-EV1 *1
Type Wired (shielded twisted-pair cable)
Communications method N:N token-bus method
Code Manchester code
Modulation Baseband code
Synchronization Flag synchronization (conforms to HDLC frames)
Transmission path format Multidrop method (bus type)
Transmission speed The following are the maximum transmission distances depending on the transmission speed.
2 Mbits/s: 500 m
1 Mbits/s: 800 m
500 kbits/s: 1 km
Maximum transmission
distance
Maximum distance between
nodes
Not specified. (Maximum transmission distance must be satisfied for the entire system.)
Medium Specified shielded twist-pair cable
Two signal wires, one shield
Node connection method PLC: Connection to terminal block
Computer: Connection using special (supplied) connector
Maximum number of nodes 32 or 62 nodes *2 *3
Applicable Programming
Devices
CX-Integrator in CX-One, CX-Net in CX-Programmer *3, and Programming Console
Communications functions Data links and message service
Number of data link words Send words per node: 4,000 words max. (CJ1W-CLK[]3), 1,000 words max. (All other Units)
Number of send/receive words per node:
12,000 words max. (Pre-Ver. 1.2)
20,000 words max. (unit Ver. 1.2 or later)
Total number of send words per network: 62,000 words max.
Data link areas PLC: Bit areas (CIO Area, Work Area, Link Area *4), Data Memory (DM), Extended DM Area (EM) Computer:
FinsGateway event memory
Message length 2,012 bytes max. (including the header)
RAS functions Polling node backup function
Self-diagnosis function (hardware checking at startup)
Echoback test and broadcast test (using the FINS command)
Watchdog timer
Error log function
Error control Manchester code check
CRC check (CCITT X16 +X12 +X5 +1)
*1. Discontinuation models in July 2012.
*2. With wired models, the maximum number of nodes is 32 if Repeater Units are not used. A Repeater Unit is required
when building a network with more than 32 nodes. If a Repeater Unit is used, be sure to use only the following
Controller Link Units or Boards and set the Wired Network 62 Node Enable Bit in the DM Parameter Area software
switches at all nodes.
CS1W-CLK23/CLK21-V1
CJ1W-CLK23/CLK21-V1
3G8F7-CLK23-E/CLK21-EV1
*3. CX-Net in CX-Programmer version 3.1 or earlier can be used only in a system with a maximum of 32 nodes (node
address 1 to 32). If a system is to be used with a maximum of 62 nodes (node addresses 1 to 62), use CX-Net in
CX-Programmer version 3.2 or higher or the CX-Integrator.
*4. CJ-series PLCs do not have a Link Area, but LR000 to LR199 are automatically converted CIO 1000 to CIO 1199.

Individual Specifications

Controller Link Units

Item Specifications
Model CJ1W-CLK23
CJ1W-CLK21-V1 *
Applicable PLC All CJ-series CPU Units
Number of mountable Units 8 max.
Installation site Install onto a CPU Backplane or Expansion Backplane (classified as a CPU Bus Unit).
Storage location of network parameters and
manually set data link tables
System Bus Unit Area (in the CPU Unit parameter area).
Storage location of routing tables CPU Unit parameter area
Weight 110 g
Current consumption: 5 V in PLC 0.35 A

* Discontinuation models in July 2012.

Controller Link Support Boards (for PCI Bus)

Item Specifications
Model 3G8F7-CLK23-E 3G8F7-CLK13-E 3G8F7-CLK53-E
Computer-compatible models IBM PC/AT or compatible
CPU: Intel Celeron 400 MHz or better
Main memory: 128 MB minimum
One or more PCI bus slots (PCI bus revision 2.0 or later, power supply: 5 V)
Free hard disk space: 70 MB min.
CD-ROM drive: One required for installation
Display: VGA (640 x 480 (pixels) min.)
(Other conditions conform to the OS.)
Compatible OS FinsGateway Version2003 *1
Windows 10 (32bit)
Windows 8 (32bit)
Windows 7 (32bit) Professional
Windows 7 (32bit) Home Premium
Windows Vista Business
Windows Vista Home Premium
FinsGateway Version3 *2
Windows XP Professional
Windows XP Home Edition
Windows 2000 Professional
Windows NT4.0 (Service Pack 3 or higher)
Windows ME
Windows 98SE
Weight 104 g 120 g (excluding mounting bracket) 124 g (excluding mounting bracket)
Current
consumption
5 V in PLC 0.35 A 0.54 A 0.60 A
External 24 V 0.35 A 0.35 A
*1. Install the software from CD Ver. 3.12 or higher if the operating system is Windows 10 or 8 (32bit).
*2. Install FinsGateway version 3 if the operating system is Windows NT 4.0 (Service pack 3 or higher), Windows ME, or
Windows 98SE. In that case, however, the new functions of Controller Link Support Boards for the PCI Bus cannot be
used (i.e., automatic data link creation with 1:N allocation, changing data link tables with active data links, 62-node
setting for wired models, and maximum of 4000 send words).

Repeater Units

Item Specifications
Model CS1W-RPT01 CS1W-RPT02 CS1W-RPT03
Supported Units/Boards All wired Controller Link Units and Boards
Note: If a maximum of 62 nodes is used, models that support 62 nodes must be used.
Transmission line Wire-to-wire Wire-to-optical (H-PCF) Wire-to-optical (GI)
Transmission line format Multi-drop
Tree
1:1 type 1:1 type
Installation Repeater Units are not mounted to the PLC. They are mounted separately with screws or on a DIN Track.
Weight 130 g 130 g (excluding mounting bracket) 130 g (excluding mounting bracket)
Allowable power supply
voltage range
20.4 to 26.4 V DC (24 V DC -15 to 10%)
Current consumption 24 V DC at 0.06 A 24 V DC at 0.07 A
Inrush current 2.5 A max. at 24 V DC (5 ms after startup)

Repeater Units are used to expand the Controller Link network for wired models. For Wired-to-optical Repeater Units, always use a set of two (1:1).
Optical Ring Controller Link Units and Boards cannot be connected to the optical cable section between Repeater Units.

 

(Unit: mm)

CJ1W-CLK23/CJ1W-CLK21-V1 *

CJ1W-CLK Dimensions 1

* Discontinuation models in July 2012.

 

Catalog Name
Catalog Number
[size]
Last Update
 CJ1W-CLK Data Sheet
[945KB]
Dec 17, 2018

Reviews

There are no reviews yet.

Be the first to review “CJ1W-CLK”

Your email address will not be published. Required fields are marked *



Exclusive products

Special category of products