{"id":1598,"date":"2019-01-04T07:50:25","date_gmt":"2019-01-04T07:50:25","guid":{"rendered":"http:\/\/store.al-tet.com\/?post_type=product&#038;p=1598"},"modified":"2019-01-04T07:50:27","modified_gmt":"2019-01-04T07:50:27","slug":"nx-eic202","status":"publish","type":"product","link":"http:\/\/store.al-tet.com\/index.php\/product\/nx-eic202\/","title":{"rendered":"NX-EIC202"},"content":{"rendered":"<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2022 Up to 63 NX-IO Units can be connected to one EtherNet\/IP Coupler Unit. Standard and high-performance units can be mixed.*<\/p>\n<p>\u2022 Each Coupler plus its I\/O form just a single EtherCAT node on the network.<\/p>\n<p>\u2022 I\/O control and safety control can be integrated by connecting Units for safety.<\/p>\n<p>\u2022 The IP address can be found on the label on the Unit, without using software.<\/p>\n<p>\u2022 Slave configuration by Sysmac Studio can be done centrally via the controller, or on-the-spot using the Coupler&#8217;s built-in USB port.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Input per Coupler Unit: Maximum 504 bytes, Output per Coupler Unit: Maximum 504 bytes<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.<br \/>\nEtherCAT\u00ae is a registered trademark of Beckhoff Automation GmbH for their patented technology. EtherNet\/IP\u2122 is the trademarks of ODVA.<br \/>\nOther company names and product names in this document are the trademarks or registered trademarks of their respective companies.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-B02\">Applicable standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Ask your OMRON representative for the most recent applicable standards for each model.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">EtherNet\/IP Coupler Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Current consumption<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Maximum I\/O power supply current<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EtherNet\/IP Coupler Unit<br \/>\n<img title=\"3412_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3412_lu_1_113-229865.gif\" alt=\"3412_lu_1_1\" \/><\/strong><\/th>\n<td class=\"center middle\">1.60 W or lower<\/td>\n<td class=\"center middle\">10 A<\/td>\n<td class=\"left middle\"><strong>NX-EIC202<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Automation Software Sysmac Studio<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nlicenses<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Media<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Sysmac Studio<br \/>\nNX-I\/O Edition<br \/>\nVer.1.[][] *1 *2<\/strong><\/th>\n<td class=\"left middle\">Sysmac Studio NX-I\/O Edition is a limited license that<br \/>\nprovides selected functions required for EtherNet\/IP<br \/>\nCoupler settings.<br \/>\nBecause this product is a license only, you need the<br \/>\nSysmac Studio Standard Edition DVD media to install it.<\/td>\n<td class=\"left middle\">1 license<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"left middle\"><strong>SYSMAC-NE001L<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Sysmac Studio<br \/>\nStandard Edition<br \/>\nVer.1.[][] *2<\/strong><\/th>\n<td class=\"left middle\">The Sysmac Studio is the software that provides an<br \/>\nintegrated environment for setting, programming,<br \/>\ndebugging and maintenance of machine automation<br \/>\ncontrollers including the NJ\/NX-series CPU Units, NY-<br \/>\nseries Industrial PC, EtherCAT Slave, and the HMI.<\/p>\n<p>Sysmac Studio runs on the following OS.<br \/>\nWindows 7 (32-bit\/64-bit version)\/<br \/>\nWindows 8 (32-bit\/64-bit version)\/<br \/>\nWindows 8.1 (32-bit\/64-bit version)\/<br \/>\nWindows 10 (32-bit\/64-bit version)<\/p>\n<p>This software provides functions of the Vision Edition.<br \/>\nRefer to your OMRON website for details such as<br \/>\nsupported models and functions.<\/td>\n<td class=\"left middle\">&#8212;<br \/>\n(Media only)<\/td>\n<td class=\"center middle\">DVD<\/td>\n<td class=\"left middle\"><strong>SYSMAC-SE200D<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. The Sysmac Studio Standard Edition with license(s) (SYSMAC-SE[][][]L) provides functions of the NX-I\/O Edition<br \/>\n(SYSMAC-NE001L).<br \/>\n*2. With the Sysmac Studio Standard Edition with license(s) (SYSMAC-SE[][][]L) version 1.10 or higher, you can use the<br \/>\nsetup functions for the EtherNet\/IP Coupler.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Connecting Cable<\/h4>\n<h4 class=\"heading-B02\">Peripheral (USB) Port<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Use a commercially available USB-certified cable.<br \/>\nSpecifications: USB 1.1 or 2.0 cable (A connector &#8211; B connector), 5.0 m max.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Recommended EtherNet\/IP Communications Cables<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>For EtherNet\/IP, required specification for the communications cables varies depending on the baud rate. For 100BASE-TX\/10BASE-T, use a straight or cross STP (shielded twisted-pair) cable of category 5 or higher. For 1000BASE-T, use a straight or cross STP cable of category 5e or higher with double shielding (aluminum tape and braiding).<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Cable with Connectors<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Appearance<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Recommended<br \/>\nmanufacturer<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Cable<br \/>\nlength<br \/>\n(m)<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">Cable with Connectors on Both Ends<br \/>\n(RJ45\/RJ45)<br \/>\nStandard RJ45 plugs type *1<br \/>\nWire Gauge and Number of Pairs:<br \/>\nAWG26, 4-pair Cable<br \/>\nCable Sheath material: LSZH *2<br \/>\nCable color: Yellow *3<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"6\"><img title=\"3412_lu_3_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3412_lu_3_113-229866.gif\" alt=\"3412_lu_3_1\" \/><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">OMRON<\/td>\n<td class=\"center middle\">0.3<\/td>\n<td class=\"left middle\"><strong>XS6W-6LSZH8SS30CM-Y<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">0.5<\/td>\n<td class=\"left middle\"><strong>XS6W-6LSZH8SS50CM-Y<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">1<\/td>\n<td class=\"left middle\"><strong>XS6W-6LSZH8SS100CM-Y<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">2<\/td>\n<td class=\"left middle\"><strong>XS6W-6LSZH8SS200CM-Y<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">3<\/td>\n<td class=\"left middle\"><strong>XS6W-6LSZH8SS300CM-Y<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">5<\/td>\n<td class=\"left middle\"><strong>XS6W-6LSZH8SS500CM-Y<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">Cable with Connectors on Both Ends<br \/>\n(RJ45\/RJ45)<br \/>\nRugged RJ45 plugs type *1<br \/>\nWire Gauge and Number of Pairs:<br \/>\nAWG22, 2-pair Cable<br \/>\nCable color: Light blue<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"6\"><img title=\"3412_lu_3_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3412_lu_3_213-229867.gif\" alt=\"3412_lu_3_2\" \/><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">OMRON<\/td>\n<td class=\"center middle\">0.3<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-AMD-K<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">0.5<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-BMD-K<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">1<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-CMD-K<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">2<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-DMD-K<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">5<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-GMD-K<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">10<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-JMD-K<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">Cable with Connectors on Both Ends<br \/>\n(M12 Straight\/M12 Straight)<br \/>\nShield Strengthening Connector cable *4<br \/>\nM12\/Smartclick Connectors<br \/>\nWire Gauge and Number of Pairs:<br \/>\nAWG22, 2-pair Cable<br \/>\nCable color: Black<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"6\"><img title=\"3412_lu_3_3\" src=\"http:\/\/www.ia.omron.com\/Images\/3412_lu_3_313-229868.gif\" alt=\"3412_lu_3_3\" \/><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">OMRON<\/td>\n<td class=\"center middle\">0.5<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-BM2-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">1<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-CM2-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">2<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-DM2-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">3<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-EM2-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">5<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-GM2-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">10<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-JM2-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">Cable with Connectors on Both Ends<br \/>\n(M12 Straight\/RJ45)<br \/>\nShield Strengthening Connector cable *4<br \/>\nM12\/Smartclick Connectors<br \/>\nRugged RJ45 plugs type<br \/>\nWire Gauge and Number of Pairs:<br \/>\nAWG22, 2-pair Cable<br \/>\nCable color: Black<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"6\"><img title=\"3412_lu_3_4\" src=\"http:\/\/www.ia.omron.com\/Images\/3412_lu_3_413-229869.gif\" alt=\"3412_lu_3_4\" \/><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">OMRON<\/td>\n<td class=\"center middle\">0.5<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-BMC-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">1<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-CMC-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">2<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-DMC-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">3<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-EMC-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">5<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-GMC-SS<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">10<\/td>\n<td class=\"left middle\"><strong>XS5W-T421-JMC-SS<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. Standard type cables length 0.2, 0.3, 0.5, 1, 1.5, 2, 3, 5, 7.5, 10, 15 and 20 m are available.<br \/>\nRugged type cables length 0.3, 0.5, 1, 2, 3, 5, 10 and 15 m are available. For details, refer to Cat.No.G019.<br \/>\n*2. The lineup features Low Smoke Zero Halogen cables for in-cabinet use and PUR cables for out-of-cabinet use.<br \/>\nAlthough the LSZH cable is single shielded, its communications and noise characteristics meet the standards.<br \/>\n*3. Cables colors are available in blue, yellow, or Green.<br \/>\n*4. For details, contact your OMRON representative.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Cables \/ Connectors<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Recommended<br \/>\nmanufacturer<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"4\">Products for<br \/>\nEtherNet\/IP<br \/>\n(100BASE-TX)<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"4\">Wire Gauge and<br \/>\nNumber of Pairs:<br \/>\nAWG24, 4-pair Cable<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Cables<\/td>\n<td class=\"left middle\">Hitachi Cable, Ltd.<\/td>\n<td class=\"left middle\"><strong>NETSTAR-C5E SAB 0.5 \u00d7 4P<br \/>\n*1<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Kuramo Electric Co.<\/td>\n<td class=\"left middle\"><strong>KETH-SB *1<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">SWCC Showa Cable<br \/>\nSystems Co.<\/td>\n<td class=\"left middle\"><strong>FAE-5004 *1<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">RJ45 Connectors<\/td>\n<td class=\"left middle\">Panduit Corporation<\/td>\n<td class=\"left middle\"><strong>MPS588-C *1<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Products for<br \/>\nEtherNet\/IP<br \/>\n(100BASE-TX)<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Wire Gauge and<br \/>\nNumber of Pairs:<br \/>\nAWG22, 2-pair Cable<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Cables<\/td>\n<td class=\"left middle\">Kuramo Electric Co.<\/td>\n<td class=\"left middle\"><strong>KETH-PSB-OMR *2<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">JMACS Japan Co., Ltd.<\/td>\n<td class=\"left middle\"><strong>PNET\/B *2<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">RJ45 Assembly<br \/>\nConnector<br \/>\n<img title=\"3412_lu_4_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3412_lu_4_113-271936.gif\" alt=\"3412_lu_4_1\" \/><\/td>\n<td class=\"left middle\">OMRON<\/td>\n<td class=\"left middle\"><strong>XS6G-T421-1 *2<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. We recommend you to use above cable for EtherNet\/IP and RJ45 Connector together.<br \/>\n*2. We recommend you to use above cable for EtherNet\/IP and RJ45 Assembly Connector together.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Optional Products<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Unit\/Terminal Block Coding Pins<\/strong><\/th>\n<td class=\"left middle\">Pins for 10 Units (30 terminal block pins and 30 Unit pins)<\/td>\n<td class=\"left middle\"><strong>NX-AUX02<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>No. of terminals<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Terminal number<br \/>\nindications<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Ground<br \/>\nterminal mark<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Terminal current<br \/>\ncapacity<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Terminal Block<\/strong><\/th>\n<td class=\"center middle\">8<\/td>\n<td class=\"center middle\">A\/B<\/td>\n<td class=\"center middle\">Provided<\/td>\n<td class=\"center middle\">10 A<\/td>\n<td class=\"left middle\"><strong>NX-TBC082<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A02\">General Specification<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Enclosure<\/strong><\/th>\n<td class=\"left middle\">Mounted in a panel<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Grounding method<\/strong><\/th>\n<td class=\"left middle\">Ground to 100 \u03a9 or less<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"11\"><strong>Operating<br \/>\nenvironment<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">0 to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\nhumidity<\/strong><\/th>\n<td class=\"left middle\">10% to 95% (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Atmosphere<\/strong><\/th>\n<td class=\"left middle\">Must be free from corrosive gases.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient storage<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">-25 to 70\u00b0C (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Altitude<\/strong><\/th>\n<td class=\"left middle\">2,000 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Pollution degree<\/strong><\/th>\n<td class=\"left middle\">Pollution degree 2 or less: Conforms to JIS B 3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Noise immunity<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 61000-4-4. 2 kV (power supply line)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Overvoltage category<\/strong><\/th>\n<td class=\"left middle\">Category II: Conforms to JIS B 3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EMC immunity level<\/strong><\/th>\n<td class=\"left middle\">Zone B<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Vibration resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-6.<br \/>\n5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m\/s<sup>2<\/sup>,<br \/>\n100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min<br \/>\ntotal) *1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Shock resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-27. 147 m\/s<sup>2<\/sup>, 3 times each in X, Y, and Z directions *1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Applicable standards *2<\/strong><\/th>\n<td class=\"left middle\">cULus: Listed UL508, ANSI\/ISA 12.12.01<br \/>\nEU: EN 61131-2, C-Tick or RCM, KC: KC Registration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Refer to the NX-series Digital I\/O Units User\u2019s Manual (Cat. No. W521) for the vibration and shock resistance<br \/>\nspecifications of the Relay Output Unit.<br \/>\n*2. Consult your OMRON representative for the most recent applicable standards for each model.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">EtherNet\/IP Coupler Unit Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">NX-EIC202<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of connectable<br \/>\nNX Units<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">63 Units max.*1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"2\"><strong>Communications<br \/>\nprotocols<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">EtherNet\/IP<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">UDP\/IP and TCP\/IP (Message Services)<\/td>\n<td class=\"left middle\">Number of buffers (sockets):<br \/>\n\u2022 8 message buffers for server<br \/>\n\u2022 No message buffers for client<br \/>\n\u2022 Shared buffers for UDP\/IP messages<br \/>\nand TCP\/IP messages<br \/>\nMaximum message size:<br \/>\n\u2022 Request: 492 bytes<br \/>\n\u2022 Response: 496 bytes<br \/>\nMaximum NX output data size:<br \/>\n\u2022 490 bytes<br \/>\nMaximum NX input data size:<br \/>\n\u2022 496 bytes<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Modulation<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Baseband<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Link speed<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">100 Mbps<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Physical layer<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">100BASE-TX (IEEE 802.3)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of connections<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">8<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Received Packet Interval<br \/>\n(RPI, refresh cycle)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">4 to 1,000 ms<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Allowed communications<br \/>\nbandwidth addressing to the<br \/>\nlocal node<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">1,000 pps<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Topology<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Line, Tree, Star<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Ethernet Switch<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Layer 2 Ethernet switch<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Transmission media<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Category 5 or higher twisted-pair cable (Recommended cable:<br \/>\ndouble-shielded cable with aluminum tape and braiding)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Transmission distance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Distance between nodes: 100 m or less<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>NX bus I\/O data size<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Input: 512 bytes max. (including input data, status, and unused areas)<br \/>\nOutput: 512 bytes max. (including output data and unused areas)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP I\/O connection<br \/>\nsize<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Input: 504 bytes max. (including input data, status, and unused areas)<br \/>\nOutput: 504 bytes max. (including output data and unused areas)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Refreshing methods<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Free-Run refreshing<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><strong>Unit<br \/>\npower<br \/>\nsupply<br \/>\n*2<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Power supply voltage<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">24 VDC (20.4 to 28.8 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power supply<br \/>\ncapacity<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">10 W max. (Refer to Installation orientation and restrictions for details.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power supply<br \/>\nefficiency<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">70%<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">No isolation between NX Unit power supply and Unit power supply terminals<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current capacity of<br \/>\npower supply<br \/>\nterminals<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">4 A max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>I\/O<br \/>\npower<br \/>\nsupply<br \/>\n*2<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Power supply voltage<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">5 to 24 VDC (4.5 to 28.8 VDC) *3<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum I\/O power<br \/>\nsupply current<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">10 A (Refer to Installation orientation and restrictions for details.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current capacity of<br \/>\npower supply<br \/>\nterminals<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">10 A max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit power consumption<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">1.60 W max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Current consumption from<br \/>\nI\/O power supply<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">10 mA max. (for 24 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Dielectric strength<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">510 VAC for 1 min, leakage current: 5 mA max. (between isolated circuits)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Insulation resistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">100 VDC, 20 M\u03a9 min. (between isolated circuits)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"3\"><strong>External connection<br \/>\nterminals<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Communications Connector<br \/>\nFor EtherNet\/IP communications.<br \/>\n\u2022 RJ45 \u00d7 2 (shielded)<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Screwless Clamping Terminal Block<br \/>\nFor Unit power supply, I\/O power supply, and grounding. Removable.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Peripheral USB Port<br \/>\nFor Sysmac Studio connection.<br \/>\n\u2022 Physical layer: USB 2.0-compliant, B-type connector<br \/>\n\u2022 Transmission distance: 5 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">46 \u00d7 100 \u00d7 71 mm (W\u00d7H\u00d7D)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">150 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Installation orientation<br \/>\nand restrictions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Installation orientation: 6 possible orientations<br \/>\nRestrictions:<br \/>\n\u2022 Used in the upright installation orientation.<br \/>\n<img title=\"3412_sp_2_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3412_sp_2_113-229870.gif\" alt=\"3412_sp_2_1\" \/><br \/>\n\u2022 Used in any other orientation than the upright installation orientation.<br \/>\n<img title=\"3412_sp_2_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3412_sp_2_213-229871.gif\" alt=\"3412_sp_2_2\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Circuit layout<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\"><img title=\"3412_sp_2_3\" src=\"http:\/\/www.ia.omron.com\/Images\/3412_sp_2_313-229872.gif\" alt=\"3412_sp_2_3\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Terminal arrangement<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\"><img title=\"3412_sp_2_4\" src=\"http:\/\/www.ia.omron.com\/Images\/3412_sp_2_413-229873.gif\" alt=\"3412_sp_2_4\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Accessory<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">End Cover (NX-END01): 1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. Refer to the NX-series Safety Control Unit User&#8217;s Manual (Cat. No. Z930) for the number of Safety Control Units that<br \/>\ncan be connected.<br \/>\n*2. Refer to the NX-series EtherNet\/IP\u2122Coupler Unit User\u2019s Manual (Cat. No. W536) for procedures for designing the<br \/>\nUnit power supply system and I\/O power supply system.<br \/>\n*3. Use a voltage that is appropriate for the I\/O circuits of the NX Units and the connected external devices.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Configuration Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Refer to the user&#8217;s manuals for information on the NX Units that can be connected to the NX-series EtherNet\/IP Coupler Unit.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">EtherNet\/IP Coupler Unit<\/h4>\n<div class=\"component-blockA01 set-width\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EtherNet\/IP Coupler Unit<\/strong><\/th>\n<td class=\"left middle\">NX-EIC202<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">I\/O Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>2-point Units<\/strong><\/th>\n<th class=\"heading center middle\"><strong>4-point Units<\/strong><\/th>\n<th class=\"heading center middle\"><strong>8-point Units<\/strong><\/th>\n<th class=\"heading center middle\"><strong>16-point Units<\/strong><\/th>\n<th class=\"heading center middle\"><strong>32-point Units<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Digital Input Unit<\/strong><\/th>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\">NX-ID3317<br \/>\nNX-ID3343<br \/>\nNX-ID3417<br \/>\nNX-ID3443<br \/>\nNX-IA3117<\/td>\n<td class=\"left middle\">NX-ID4342<br \/>\nNX-ID4442<\/td>\n<td class=\"left middle\">NX-ID5142-1<br \/>\nNX-ID5142-5<br \/>\nNX-ID5342<br \/>\nNX-ID5442<\/td>\n<td class=\"left middle\">NX-ID6142-5<br \/>\nNX-ID6142-6<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Digital Output Unit<\/strong><\/th>\n<td class=\"left middle\">NX-OC2633<br \/>\nNX-OC2733<\/td>\n<td class=\"left middle\">NX-OD3121<br \/>\nNX-OD3153<br \/>\nNX-OD3256<br \/>\nNX-OD3257<br \/>\nNX-OD3268<\/td>\n<td class=\"left middle\">NX-OD4121<br \/>\nNX-OD4256<br \/>\nNX-OC4633<\/td>\n<td class=\"left middle\">NX-OD5121<br \/>\nNX-OD5121-1<br \/>\nNX-OD5121-5<br \/>\nNX-OD5256<br \/>\nNX-OD5256-1<br \/>\nNX-OD5256-5<\/td>\n<td class=\"left middle\">NX-OD6121-5<br \/>\nNX-OD6256-5<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Digital Mixed I\/O Unit<\/strong><\/th>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\">NX-MD6121-5<br \/>\nNX-MD6121-6<br \/>\nNX-MD6256-5<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Analog Input Unit<\/strong><\/th>\n<td class=\"left middle\">NX-AD2603<br \/>\nNX-AD2604<br \/>\nNX-AD2608<br \/>\nNX-AD2203<br \/>\nNX-AD2204<br \/>\nNX-AD2208<\/td>\n<td class=\"left middle\">NX-AD3603<br \/>\nNX-AD3604<br \/>\nNX-AD3608<br \/>\nNX-AD3203<br \/>\nNX-AD3204<br \/>\nNX-AD3208<\/td>\n<td class=\"left middle\">NX-AD4603<br \/>\nNX-AD4604<br \/>\nNX-AD4608<br \/>\nNX-AD4203<br \/>\nNX-AD4204<br \/>\nNX-AD4208<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Analog Output Unit<\/strong><\/th>\n<td class=\"left middle\">NX-DA2603<br \/>\nNX-DA2605<br \/>\nNX-DA2203<br \/>\nNX-DA2205<\/td>\n<td class=\"left middle\">NX-DA3603<br \/>\nNX-DA3605<br \/>\nNX-DA3203<br \/>\nNX-DA3205<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Temperature Input Unit<\/strong><\/th>\n<td class=\"left middle\">NX-TS2101<br \/>\nNX-TS2102<br \/>\nNX-TS2104<br \/>\nNX-TS2201<br \/>\nNX-TS2202<br \/>\nNX-TS2204<\/td>\n<td class=\"left middle\">NX-TS3101<br \/>\nNX-TS3102<br \/>\nNX-TS3104<br \/>\nNX-TS3201<br \/>\nNX-TS3202<br \/>\nNX-TS3204<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Heater Burnout<br \/>\nDetection Unit<\/strong><\/th>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\">NX-HB3101<br \/>\nNX-HB3201<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Temperature Control Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>2CH<\/strong><\/th>\n<th class=\"heading center middle\"><strong>4CH<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Temperature Control Unit<\/strong><\/th>\n<td class=\"left middle\">NX-TC2405, NX-TC2406, NX-TC2407,<br \/>\nNX-TC2408<\/td>\n<td class=\"left middle\">NX-TC3405, NX-TC3406, NX-TC3407,<br \/>\nNX-TC3408<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Load Cell Input Unit<\/h4>\n<div class=\"component-blockA01 set-width\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Load Cell Input Unit<\/strong><\/th>\n<td class=\"left middle\">NX-RS1201<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Position Interface Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>1CH<\/strong><\/th>\n<th class=\"heading center middle\"><strong>2CH<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Incremental Encoder Input Unit<\/strong><\/th>\n<td class=\"left middle\">NX-EC0112, NX-EC0122, NX-EC0132, NX-EC0142<\/td>\n<td class=\"left middle\">NX-EC0212, NX-EC0222<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>SSI Input Unit<\/strong><\/th>\n<td class=\"left middle\">NX-ECS112<\/td>\n<td class=\"left middle\">NX-ECS212<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Pulse Output Unit<\/strong><\/th>\n<td class=\"left middle\">NX-PG0112, NX-PG0122<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Communications Interface Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Communications Interface Unit<\/strong><\/th>\n<td class=\"left middle\">NX-CIF101, NX-CIF105, NX-CIF210<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">System Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Additional NX Unit Power Supply Unit<\/strong><\/th>\n<td class=\"left middle\">NX-PD1000<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Additional I\/O Power Supply Unit<\/strong><\/th>\n<td class=\"left middle\">NX-PF0630, NX-PF0730<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O Power Supply Connection Unit<\/strong><\/th>\n<td class=\"left middle\">NX-PC0010, NX-PC0020, NX-PC0030<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Shield Connection Unit<\/strong><\/th>\n<td class=\"left middle\">NX-TBX01<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">IO-Link Master Unit<\/h4>\n<div class=\"component-blockA01 set-width\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>IO-Link Master Unit<\/strong><\/th>\n<td class=\"left middle\">NX-ILM400<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Safety Control Units<\/h4>\n<div class=\"component-blockA01 set-width\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Safety CPU Unit<\/strong><\/th>\n<td class=\"left middle\">NX-SL3300 *1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Safety Input Unit<\/strong><\/th>\n<td class=\"left middle\">NX-SIH400 *2, NX-SID800<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Safety Output Unit<\/strong><\/th>\n<td class=\"left middle\">NX-SOH200, NX-SOD400<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1 Safety CPU Unit Ver.1.1 or higher.<br \/>\n*2 Safety Input Unit Ver.1.1 or higher.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Version Information<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Depending on the type and model of the Unit, some Units do not have all of the versions given in the corresponding versions. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user\u2019s manuals for the specific Units for the relation between models and versions.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Connection to the NJ\/NX-series CPU Unit or NY-series Industrial PC<\/h4>\n<h4 class=\"heading-B02\">NX-series CPU Unit or NY-series Industrial PC<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP Coupler Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Corresponding unit version\/version<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version of<br \/>\nCPU Unit or<br \/>\nIndustrial PC<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Studio<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Network Configurator<br \/>\nfor EtherNet\/IP<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CX-ConfiguratorFDT<br \/>\nversion<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-EIC202<\/td>\n<td class=\"center middle\">Ver.1.2<\/td>\n<td class=\"center middle\">Ver.1.14<\/td>\n<td class=\"center middle\">Ver.1.19<\/td>\n<td class=\"center middle\">Ver.3.21<\/td>\n<td class=\"center middle\">Ver.2.4 *<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver.1.0<\/td>\n<td class=\"center middle\">Not possible.<\/td>\n<td class=\"center middle\">Not possible.<\/td>\n<td class=\"center middle\">Not possible.<\/td>\n<td class=\"center middle\">Not possible.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>* The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the<br \/>\nEtherNet\/IP Coupler Unit.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">NJ-series CPU Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP Coupler Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>Corresponding unit version\/version<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<br \/>\nof CPU Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<br \/>\nof<br \/>\nCJ1W-EIP21<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Network<br \/>\nConfigurator for<br \/>\nEtherNet\/IP<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CX-<br \/>\nConfiguratorFDT<br \/>\nversion<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-EIC202<\/td>\n<td class=\"center middle\">Ver.1.2<\/td>\n<td class=\"center middle\">Ver.1.14<\/td>\n<td class=\"center middle\">Ver.2.1<\/td>\n<td class=\"center middle\">Ver.1.19<\/td>\n<td class=\"center middle\">Ver.3.21<\/td>\n<td class=\"center middle\">Ver.2.4 *<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver.1.0<\/td>\n<td class=\"center middle\">Not possible.<\/td>\n<td class=\"center middle\">Not possible.<\/td>\n<td class=\"center middle\">Not possible.<\/td>\n<td class=\"center middle\">Not possible.<\/td>\n<td class=\"center middle\">Not possible.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>* The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the<br \/>\nEtherNet\/IP Coupler Unit.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Connection to CS\/CJ\/CP-series CPU Unit<\/h4>\n<h4 class=\"heading-B02\">CS1G\/CS1H\/CJ1H\/CJ1M CPU Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP Coupler Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>Corresponding unit version\/version<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<br \/>\nof CPU Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<br \/>\nof<br \/>\nCS1W-EIP21\/<br \/>\nCJ1W-EIP21<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Network<br \/>\nConfigurator for<br \/>\nEtherNet\/IP<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NX-IO<br \/>\nConfigurator<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CX-<br \/>\nConfiguratorFDT<br \/>\nversion<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-EIC202<\/td>\n<td class=\"center middle\">Ver.1.2<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.3.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.2.1<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.3.00<\/td>\n<td class=\"center middle\">Ver.1.00<\/td>\n<td class=\"center middle\">Ver.2.4 *1<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver.1.0<\/td>\n<td class=\"center middle\">Ver.1.00 *2<\/td>\n<td class=\"center middle\">Ver.2.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the<br \/>\nEtherNet\/IP Coupler Unit.<br \/>\n*2. You can connect only to the peripheral USB port on the EtherNet\/IP Coupler Unit. You cannot connect with any other<br \/>\npath.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CJ2H-CPU6[]\/CJ2M-CPU1[]\/CP1H CPU Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP Coupler Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>Corresponding unit version\/version<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<br \/>\nof CPU Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<br \/>\nof<br \/>\nCJ1W-EIP21<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Network<br \/>\nConfigurator for<br \/>\nEtherNet\/IP<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NX-IO<br \/>\nConfigurator<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CX-<br \/>\nConfiguratorFDT<br \/>\nversion<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-EIC202<\/td>\n<td class=\"center middle\">Ver.1.2<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.2.1<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.3.00<\/td>\n<td class=\"center middle\">Ver.1.00<\/td>\n<td class=\"center middle\">Ver.2.4 *1<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver.1.0<\/td>\n<td class=\"center middle\">Ver.1.00 *2<\/td>\n<td class=\"center middle\">Ver.2.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the<br \/>\nEtherNet\/IP Coupler Unit.<br \/>\n*2. You can connect only to the peripheral USB port on the EtherNet\/IP Coupler Unit. You cannot connect with any other<br \/>\npath.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CJ2H-CPU6[]-EIP CPU Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP Coupler Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>Corresponding unit version\/version<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<br \/>\nof CPU Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<br \/>\nof<br \/>\nCJ1W-EIP21<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Network<br \/>\nConfigurator for<br \/>\nEtherNet\/IP<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NX-IO<br \/>\nConfigurator<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CX-<br \/>\nConfiguratorFDT<br \/>\nversion<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-EIC202<\/td>\n<td class=\"center middle\">Ver.1.2<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.1.5<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.2.1<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.3.00<\/td>\n<td class=\"center middle\">Ver.1.00<\/td>\n<td class=\"center middle\">Ver.2.4 *1<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver.1.0<\/td>\n<td class=\"center middle\">Ver.1.00 *2<\/td>\n<td class=\"center middle\">Ver.2.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the<br \/>\nEtherNet\/IP Coupler Unit.<br \/>\n*2. You can connect only to the peripheral USB port on the EtherNet\/IP Coupler Unit. You cannot connect with any other<br \/>\npath.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CJ2M-CPU3[] CPU Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP Coupler Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>Corresponding unit version\/version<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<br \/>\nof CPU Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<br \/>\nof<br \/>\nCJ1W-EIP21<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Network<br \/>\nConfigurator for<br \/>\nEtherNet\/IP<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NX-IO<br \/>\nConfigurator<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CX-<br \/>\nConfiguratorFDT<br \/>\nversion<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-EIC202<\/td>\n<td class=\"center middle\">Ver.1.2<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.2.1<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.3.21<\/td>\n<td class=\"center middle\">Ver.1.00<\/td>\n<td class=\"center middle\">Ver.2.4 *1<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver.1.0<\/td>\n<td class=\"center middle\">Ver.1.00 *2<\/td>\n<td class=\"center middle\">Ver.2.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the<br \/>\nEtherNet\/IP Coupler Unit.<br \/>\n*2. You can connect only to the peripheral USB port on the EtherNet\/IP Coupler Unit. You cannot connect with any other<br \/>\npath.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Connection to the Sysmac Gateway<\/h4>\n<h4 class=\"heading-B02\">Sysmac Gateway<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP Coupler Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Corresponding unit version\/version<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Gateway<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Network Configurator<br \/>\nfor EtherNet\/IP version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NX-IO<br \/>\nConfigurator<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CX-<br \/>\nConfiguratorFDT<br \/>\nversion<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-EIC202<\/td>\n<td class=\"center middle\">Ver.1.2<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.1.31<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver.3.50<\/td>\n<td class=\"center middle\">Ver.1.00<\/td>\n<td class=\"center middle\">Ver.2.4 *1<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver.1.0<\/td>\n<td class=\"center middle\">Ver.1.00 *2<\/td>\n<td class=\"center middle\">Ver.2.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port on the<br \/>\nEtherNet\/IP Coupler Unit.<br \/>\n*2. You can connect only to the peripheral USB port on the EtherNet\/IP Coupler Unit. You cannot connect with any other<br \/>\npath.<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div>\n<h4 class=\"heading-B02\">EtherCAT Coupler Unit Only<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3412_dm_113-229874.gif\" alt=\"NX-EIC202 Dimensions 1 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">With Cables Connected<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3412_dm_213-229875.gif\" alt=\"NX-EIC202 Dimensions 2 \" \/><\/div>\n<div class=\"text\">\n<p>*1. This dimension depends on the specifications of the commercially available USB-certified cable.<br \/>\nCheck the specifications of the USB cable that is used.<br \/>\n*2. This is the dimension from the back of the Unit to the communications cables.<br \/>\n\u2022 100 mm: When an MPS588-C Connector is used.<br \/>\n\u2022 120 mm: When an XS6G-T421-1 Connector is used.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">End Cover<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3412_dm_313-229876.gif\" alt=\"NX-EIC202 Dimensions 3 \" \/><\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div class=\"inner-contents-area\">\n<div class=\"primary-contents-area\">\n<div class=\"tabpanel-blockA01\">\n<div class=\"editable-block\">\n<div class=\"table-blockA01\">\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/nx-eic_ds_e_3_2_csm1055927.pdf?id=3412\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-EIC Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[2224KB]<\/span><\/td>\n<td class=\"td_date\">Aug 01, 2018<\/td>\n<\/tr>\n<tr class=\"even\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/nx_series_r183-e1_7_6_csm1040123.pdf?id=3412\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-series I\/O System Catalog<\/a><\/td>\n<td>R183-E1-09<br \/>\n<span class=\"file-size\">[6683KB]<\/span><\/td>\n<td class=\"td_date\">Nov 01, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"local-navi-area\">\n<div class=\"local-navi-area\">\n<div class=\"local-naviA01\">\n<h2 class=\"heading-link\"><\/h2>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">Connecting to open industrial network standard EtherNet\/IP<\/h2>\n","protected":false},"featured_media":1599,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[91,63,72],"product_tag":[],"_links":{"self":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product\/1598"}],"collection":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/comments?post=1598"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media\/1599"}],"wp:attachment":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media?parent=1598"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1598"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1598"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}