{"id":1597,"date":"2019-01-04T07:45:34","date_gmt":"2019-01-04T07:45:34","guid":{"rendered":"http:\/\/store.al-tet.com\/?post_type=product&#038;p=1597"},"modified":"2019-01-04T07:45:35","modified_gmt":"2019-01-04T07:45:35","slug":"cj1w-drm21-3","status":"publish","type":"product","link":"http:\/\/store.al-tet.com\/index.php\/product\/cj1w-drm21-3\/","title":{"rendered":"CJ1W-DRM21"},"content":{"rendered":"<p>\u2022 Allows control of up to 32,000 points (2,000 words) per master, and ensures a high degree of simultaneity between data.<\/p>\n<p>\u2022 Can be used as both a master and a slave at the same time.<\/p>\n<p>\u2022 Equipped with settings and monitor functions aimed at improving both design and startup efficiency. Achieve maximum performance by using in combination with a Configurator.<\/p>\n<p>\u2022 Files of master and slave settings can be uploaded and downloaded using memory cards, allowing effective debugging and easier setup.<\/p>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-B02\">International Standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<ul class=\"listA01\">\n<li>The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.<\/li>\n<li>Contact your OMRON representative for further details and applicable conditions for these standards.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nclassifi-<br \/>\ncation<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Communications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>No. of<br \/>\nunit<br \/>\nnumbers<br \/>\nallocated<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Current<br \/>\nconsumption<br \/>\n(A)<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>5 V<\/strong><\/th>\n<th class=\"heading center middle\"><strong>24 V<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>CJ1 CPU<br \/>\nBus Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong><img title=\"28_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/28_lu_1_113-247202.gif\" alt=\"28_lu_1_1\" \/><\/strong><\/th>\n<td class=\"left middle\">Equipped with<br \/>\nMaster and Slave<br \/>\nfunctionality.<br \/>\nControls for up to<br \/>\n32,000 points per<br \/>\nMaster.<\/td>\n<td class=\"left middle\">Remote I\/O Communications<br \/>\nMaster (fixed allocations or<br \/>\nuser-set allocations)<br \/>\nRemote I\/O Communications<br \/>\nSlave (fixed allocations or<br \/>\nuser-set allocations)<br \/>\nMessage communications<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"center middle\">0.29<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\"><strong>CJ1W-DRM21<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Note: When using with the Machine Automation Controller NJ Series, note the following points:<br \/>\n\u2022 Simple backup function cannot be used.<br \/>\n\u2022 DeviceNet configurator cannot be used. Use CX-Integrator.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Software<\/h4>\n<h4 class=\"heading-A03\">How to Select Required Support Software for Your Controller<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Item<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Omron PLC System<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Omron Machine Automation Controller System<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Controller<\/strong><\/th>\n<td class=\"left middle\">CS, CJ, CP, and other series<\/td>\n<td class=\"left middle\">NJ-series<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Software<\/strong><\/th>\n<td class=\"left middle\">FA Integrated Tool Package CX-One<\/td>\n<td class=\"left middle\">Automation Software Sysmac Studio<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">FA Integrated Tool Package CX-One<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Stand-<br \/>\nards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nlicenses<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Media<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>FA Integrated<br \/>\nTool Package<br \/>\nCX-One<br \/>\nVer.4.[]<\/strong><\/th>\n<td class=\"left middle\">The CX-One is a comprehensive software<br \/>\npackage that integrates Support Software<br \/>\nfor OMRON PLCs and components.<\/p>\n<p>CX-One runs on the following OS.<br \/>\nOS:<br \/>\nWindows XP<br \/>\n(Service Pack 3 or higher,32-bit version)\/<br \/>\nWindows Vista (32-bit\/64-bitversion)\/<br \/>\nWindows 7 (32-bit\/64-bit version)\/<br \/>\nWindows 8 (32-bit\/64-bit version)\/<br \/>\nWindows 8.1 (32-bit\/64-bit version)\/<br \/>\nWindows 10 (32-bit\/64-bit version)<\/p>\n<p>CX-One Version 4.[] includes CX-Integrator<br \/>\nVer.3.[].<br \/>\nFor details, refer to the CX-One catalog<br \/>\n(Cat. No. R134)<\/td>\n<td class=\"center middle\">1 license *1<\/td>\n<td class=\"center middle\">DVD *2<\/td>\n<td class=\"left middle\"><strong>CXONE-AL01D-V4<\/strong><\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.<br \/>\n*2. The CX-One is also available on CD (CXONE-AL[][]C-V4).<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Automation Software Sysmac Studio<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Stand-<br \/>\nards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nlicenses<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Media<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Sysmac<br \/>\nStudio<br \/>\nStandard<br \/>\nEdition<br \/>\nVer.1.[][]<\/strong><\/th>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">The Sysmac Studio is the software that provides an<br \/>\nintegrated environment for setting, programming,<br \/>\ndebugging and maintenance of machine automation<br \/>\ncontrollers including the NJ\/NX-series CPU Units,<br \/>\nNY-series Industrial PC, EtherCAT Slave, and the HMI.<\/p>\n<p>Sysmac Studio runs on the following OS.<br \/>\nOS:<br \/>\nWindows 7 (32-bit\/64-bit version) \/<br \/>\nWindows 8 (32-bit\/64-bit version) \/<br \/>\nWindows 8.1 (32-bit\/64-bit version) \/<br \/>\nWindows 10 (32-bit\/64-bit version)<\/p>\n<p>The Sysmac Studio Standard Edition DVD includes<br \/>\nSupport Software to set up EtherNet\/IP Units,<br \/>\nDeviceNet slaves, Serial Communications Units, and<br \/>\nSupport Software for creating screens on HMIs<br \/>\n(CX-Designer).<br \/>\nRefer to your OMRON website for details.<\/td>\n<td class=\"center middle\">&#8211;<br \/>\n(Media only)<\/td>\n<td class=\"center middle\">DVD<\/td>\n<td class=\"left middle\"><strong>SYSMAC-SE200D<\/strong><\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">1 license<br \/>\n*<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\"><strong>SYSMAC-SE201L<\/strong><\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A02\">Communication Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Item<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Communications protocol<\/strong><\/th>\n<td class=\"left middle\" colspan=\"4\" rowspan=\"1\">DeviceNet<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Connection methods<\/strong><\/th>\n<td class=\"left middle\" colspan=\"4\" rowspan=\"1\">Multi-drop and T-branch connections can be combined (for trunk and branch lines) *1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Baud rate<\/strong><\/th>\n<td class=\"left middle\" colspan=\"4\" rowspan=\"1\">500 Kbps, 250 Kbps, or 125 Kbps<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Communications media<\/strong><\/th>\n<td class=\"left middle\" colspan=\"4\" rowspan=\"1\">Special 5-wire cables (2 signal lines, 2 power lines, 1 shield line)<br \/>\nSpecial 4-wire flat cables (2 signal lines, 2 power lines)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Communications distances for<br \/>\nspecial 5-wire cables<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Baud rate<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Network length<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Branch line length<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Total branch line length<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"center middle\">500 kbps<\/td>\n<td class=\"center middle\">100 m max.<\/td>\n<td class=\"center middle\">6 m max.<\/td>\n<td class=\"center middle\">39 m max.<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">250 kbps<\/td>\n<td class=\"center middle\">250 m max. *2<\/td>\n<td class=\"center middle\">6 m max.<\/td>\n<td class=\"center middle\">78 m max.<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">125 kbps<\/td>\n<td class=\"center middle\">500 m max. *2<\/td>\n<td class=\"center middle\">6 m max.<\/td>\n<td class=\"center middle\">156 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Communications distances for<br \/>\nspecial 4-wire flat cables<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Baud rate<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Network length<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Branch line length<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Total branch line length<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"center middle\">500 kbps<\/td>\n<td class=\"center middle\">75 m max.<\/td>\n<td class=\"center middle\">6 m max.<\/td>\n<td class=\"center middle\">35 m max.<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">250 kbps<\/td>\n<td class=\"center middle\">150 m max.<\/td>\n<td class=\"center middle\">6 m max.<\/td>\n<td class=\"center middle\">48 m max.<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">125 kbps<\/td>\n<td class=\"center middle\">265 m max.<\/td>\n<td class=\"center middle\">6 m max.<\/td>\n<td class=\"center middle\">135 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Communications power supply<\/strong><\/th>\n<td class=\"left middle\" colspan=\"4\" rowspan=\"1\">24 V DC supplied externally<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Max. number of nodes<\/strong><\/th>\n<td class=\"left middle\" colspan=\"4\" rowspan=\"1\">64 nodes (including Masters, Slaves, and Configurator)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Terminators are required at both ends of trunk line.<br \/>\n*2. Indicates the maximum network length when thick cables are used. Reduce the network length to 100 m max. when<br \/>\nusing thin cables.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Network Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/28_sp_213-119651.gif\" alt=\"CJ1W-DRM21 Specifications 3 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Communications power supply voltage<\/strong><\/th>\n<td class=\"left middle\">11 to 25 VDC<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Current consumption<\/strong><\/th>\n<td class=\"left middle\">Communications:18 mA max.<br \/>\nInternal circuit: 290 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Max. number<br \/>\nof connectable<br \/>\nslaves<\/strong><\/th>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Remote I\/O, explicit message service<\/strong><\/td>\n<td class=\"left middle\">63 *1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Max. number<br \/>\nof I\/O points<\/strong><\/th>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"2\"><strong>Fixed allocations<\/strong><\/td>\n<th class=\"heading left middle\"><strong>When used<br \/>\nas a master<\/strong><\/th>\n<td class=\"left middle\">2,048 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>When used<br \/>\nas a slave<\/strong><\/th>\n<td class=\"left middle\">32 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>User-set<br \/>\nallocations<\/strong><\/th>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Using<br \/>\nallocated<br \/>\nDM Area<br \/>\nwords<\/strong><\/td>\n<th class=\"heading left middle\"><strong>When used<br \/>\nas a master<\/strong><\/th>\n<td class=\"left middle\">16,000 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>When used<br \/>\nas a slave<\/strong><\/th>\n<td class=\"left middle\">3,200 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Using<br \/>\nConfigurator<\/strong><\/th>\n<td class=\"heading left middle\"><strong>When used<br \/>\nas a master<\/strong><\/td>\n<td class=\"left middle\">32,000 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>When used<br \/>\nas a slave<\/strong><\/th>\n<td class=\"left middle\">4,800 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Number of<br \/>\nallocated<br \/>\nwords<\/strong><\/th>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"2\"><strong>Fixed allocations<\/strong><\/td>\n<th class=\"heading left middle\"><strong>When used<br \/>\nas a master<\/strong><\/th>\n<td class=\"left middle\">64 input and 64 output words<br \/>\nSoftware switch\/status area: 25 words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>When used<br \/>\nas a slave<\/strong><\/th>\n<td class=\"left middle\">1 input word, 1 output word *2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>User-set<br \/>\nallocations<\/strong><\/th>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Using<br \/>\nallocated<br \/>\nDM Area<br \/>\nwords<\/strong><\/td>\n<th class=\"heading left middle\"><strong>When used<br \/>\nas a master<\/strong><\/th>\n<td class=\"left middle\">500 input and 500 output words<br \/>\nSoftware switch\/status area: 25 words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>When used<br \/>\nas a slave<\/strong><\/th>\n<td class=\"left middle\">100 input and 100 output words *2<br \/>\nSoftware switch\/status area: 25 words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Using<br \/>\nConfigurator<\/strong><\/th>\n<td class=\"heading left middle\"><strong>When used<br \/>\nas a master<\/strong><\/td>\n<td class=\"left middle\">500 input words x 2 blocks, 500 output words x 2 blocks<br \/>\nSoftware switch\/Status area: 25 words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>When used<br \/>\nas a slave<\/strong><\/th>\n<td class=\"left middle\">100 input words x 1 blocks, 100 output words x 2 blocks *2<br \/>\nSoftware switch\/Status area: 25 words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Message com-<br \/>\nmunications<\/strong><\/th>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Max. message length<\/strong><\/td>\n<td class=\"left middle\">542 bytes *3<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Applicable Controllers<\/strong><\/th>\n<td class=\"left middle\">CJ\/NJ Series<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Max. number<br \/>\nof Units<br \/>\nmountable to<br \/>\nController<\/strong><\/th>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Fixed allocations<\/strong><\/td>\n<td class=\"left middle\">3<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>User-set allocations<\/strong><\/th>\n<td class=\"left middle\">16<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">118 g max.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Refer to the DeviceNet Operation Manual (W267) for the communications power supply specifications.<br \/>\n*2. The Device Unit uses a node, and so connection is possible to 63 slaves only.<br \/>\n*3. When the DeviceNet is used as a slave, &#8220;input&#8221; and &#8220;output&#8221; respectively refer to input from the slave to the master<br \/>\nand output from the master to the slave.<br \/>\n*4. The maximum message length includes the command code when using the CMND instruction. (SendCmd instruction<br \/>\nwith NJ-series controller)<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CJ1W-DRM21<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/cj1w-drm21_dm_113-119652.jpg\" alt=\"CJ1W-DRM21 Dimensions 1 \" \/><\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div class=\"inner-contents-area\">\n<div class=\"primary-contents-area\">\n<div class=\"tabpanel-blockA01\">\n<div class=\"editable-block\">\n<div class=\"table-blockA01\">\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj1w-drm21_ds_e_8_5_csm1635.pdf?id=28\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CJ1W-DRM21 Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[918KB]<\/span><\/td>\n<td class=\"td_date\">Feb 01, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"local-navi-area\">\n<div class=\"local-navi-area\">\n<div class=\"local-naviA01\">\n<h2 class=\"heading-link\"><\/h2>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">Smallest in the Industry! A DeviceNet Unit for the CJ Series that Boasts Industry-leading Performance and Functions<\/h2>\n<div class=\"item-list-link\">\n<p><a href=\"http:\/\/www.ia.omron.com\/products\/family\/28\/itemlist\/index.html\"><img loading=\"lazy\" class=\"iconA01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_right_b.gif\" alt=\"\" width=\"3\" height=\"9\" \/>\u00a0Item list<\/a><\/p>\n<\/div>\n","protected":false},"featured_media":1451,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[91,63,72],"product_tag":[],"_links":{"self":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product\/1597"}],"collection":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/comments?post=1597"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media\/1451"}],"wp:attachment":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media?parent=1597"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1597"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}