{"id":1565,"date":"2019-01-03T09:27:49","date_gmt":"2019-01-03T09:27:49","guid":{"rendered":"http:\/\/store.al-tet.com\/?post_type=product&#038;p=1565"},"modified":"2019-01-03T09:27:54","modified_gmt":"2019-01-03T09:27:54","slug":"cj2h-cpu6","status":"publish","type":"product","link":"http:\/\/store.al-tet.com\/index.php\/product\/cj2h-cpu6\/","title":{"rendered":"CJ2H-CPU6[]"},"content":{"rendered":"<p>\u2022 Even more program memory and data memory.<\/p>\n<p>\u2022 Superior high-speed control performance: LOAD instructions execute in 16 ns, SINE instructions in 0.59 \u03bcs.<\/p>\n<p>\u2022 Maximum throughputs with High-speed interrupt function<\/p>\n<p>\u2022 Efficient debugging through highly improved Data tracing<\/p>\n<p>\u2022 Secure system from memory error brought by Memory Self-restoration Function<\/p>\n<p>\u2022 The more advanced motion control by the lower cost: Synchronous Unit Operation<\/p>\n<p>\u2022 Increased I\/O throughput speed by Immediate refreshing instructions with direct processing.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-B02\">Applicable standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Ask your OMRON representative for the most recent applicable standards for each model.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">CJ2H CPU Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Current<br \/>\nconsumption<br \/>\n(A)<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>I\/O capacity\/<br \/>\nMountable Units<br \/>\n(Expansion Racks)<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Program<br \/>\ncapacity<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Data memory<br \/>\ncapacity<\/strong><\/th>\n<th class=\"heading center middle\"><strong>LD<br \/>\ninstruction<br \/>\nexecution<br \/>\ntime<\/strong><\/th>\n<th class=\"heading center middle\"><strong>5 V<\/strong><\/th>\n<th class=\"heading center middle\"><strong>24 V<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><strong>CJ2H<br \/>\nCPU Units<br \/>\n<img title=\"2045_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/2045_lu_1_113-183573.gif\" alt=\"2045_lu_1_1\" \/><\/strong><\/th>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"5\">2,560 points\/<br \/>\n40 Units<br \/>\n(3 Expansion Racks<br \/>\nmax.)<\/td>\n<td class=\"left middle\">400K steps<\/td>\n<td class=\"left middle\">832K words<br \/>\nDM: 32K words<br \/>\nEM: 32K words \u00d7<br \/>\n25 banks<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"5\">0.016 \u03bcs<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"5\">0.42 *<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"5\">&#8212;<\/td>\n<td class=\"left middle\"><strong>CJ2H-CPU68<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">250K steps<\/td>\n<td class=\"left middle\">512K words<br \/>\nDM: 32K words<br \/>\nEM: 32K words \u00d7<br \/>\n15 banks<\/td>\n<td class=\"left middle\"><strong>CJ2H-CPU67<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">150K steps<\/td>\n<td class=\"left middle\">352K words<br \/>\nDM: 32K words<br \/>\nEM: 32K words \u00d7<br \/>\n10 banks<\/td>\n<td class=\"left middle\"><strong>CJ2H-CPU66<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">100K steps<\/td>\n<td class=\"left middle\">160K words<br \/>\nDM: 32K words<br \/>\nEM: 32K words \u00d7<br \/>\n4 banks<\/td>\n<td class=\"left middle\"><strong>CJ2H-CPU65<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">50K steps<\/td>\n<td class=\"left middle\">160K words<br \/>\nDM: 32K words<br \/>\nEM: 32K words \u00d7<br \/>\n4 banks<\/td>\n<td class=\"left middle\"><strong>CJ2H-CPU64<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>* Add 0.15 A per Adapter when using NT-AL001 RS-232C\/RS-422A Adapters.<br \/>\nAdd 0.04 A per Adapter when using CJ1W-CIF11 RS-422A Adapters.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Accessories<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The following accessories come with CPU Unit:<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Battery<\/strong><\/th>\n<td class=\"left middle\">CJ1W-BAT01<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>End Cover<\/strong><\/th>\n<td class=\"left middle\">CJ1W-TER01 (necessary to be mounted at the right end of CPU Rack)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>End Plate<\/strong><\/th>\n<td class=\"left middle\">PFP-M (2 pcs)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Note: A serial port (RS-232C) connector is not provided. Purchase a connector separately for serial port connection.<br \/>\nPlug : XM3A-0921 (manufactured by OMRON) or equivalent<br \/>\nHood : XM2S-0911-E (manufactured by OMRON) or equivalent<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div>\n<h4 class=\"heading-A02\">General Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"2\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>CJ2H-<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>CPU64<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU65<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU66<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU67<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU68<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Enclosure<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Mounted in a panel<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Grounding<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Less than 100 \u03a9<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CPU Rack Dimensions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">90 mm \u00d7 65 mm \u00d7 49 mm (H \u00d7 D \u00d7 W)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight *<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">190 g or less<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Current Consumption<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">5 VDC, 0.42 A<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"11\"><strong>Use<br \/>\nEnvironment<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Ambient Operating<br \/>\nTemperature<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">0 to 55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient Operating<br \/>\nHumidity<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">10% to 90% (with no condensation)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Atmosphere<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Must be free from corrosive gases.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient Storage<br \/>\nTemperature<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">&#8211; 20 to 70 \u00b0C (excluding battery)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Altitude<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2,000 m or less<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Pollution Degree<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2 or less: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Noise Immunity<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2 kV on power supply line (Conforms to IEC 61000-4-4.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Overvoltage Category<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Category II: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EMC Immunity Level<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Zone B<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Vibration Resistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Conforms to IEC60068-2-6.<br \/>\n5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz<br \/>\nAcceleration of 9.8 m\/s<sup>2<\/sup>\u00a0for 100 min in X, Y, and Z directions (10 sweeps of<br \/>\n10 min each = 100 min total)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Shock Resistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Conforms to IEC60068-2-27.<br \/>\n147 m\/s<sup>2<\/sup>, 3 times in X, Y, and Z directions (100 m\/s<sup>2<\/sup>\u00a0for Relay Output Units)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Battery<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Life<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">5 years at 25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Approx. 10 g<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">CJ1W-BAT01<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Applicable Standards<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Conforms to cULus, NK, LR and EC Directives.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Includes wight of end covers and battery.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Performance Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"2\"><strong>Items<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>CJ2H-<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>CPU64<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU65<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU66<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU67<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU68<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>User Memory<\/strong><\/th>\n<td class=\"left middle\">50K steps<\/td>\n<td class=\"left middle\">100K steps<\/td>\n<td class=\"left middle\">150K steps<\/td>\n<td class=\"left middle\">250K steps<\/td>\n<td class=\"left middle\">400K steps<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>I\/O Bits<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2,560 bits<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Processing<br \/>\nSpeed<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Overhead Processing Time<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Normal Mode: 100 \u03bcs<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Execution Time<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Basic Instructions: 0.016 \u03bcs min.;<br \/>\nSpecial Instructions: 0.048 \u03bcs min.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Interrupts<\/strong><\/th>\n<th class=\"heading left middle\"><strong>I\/O Interrupts and<br \/>\nExternal Interrupts<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Interrupt task startup time: 26\u03bcs or 17 \u03bcs *<br \/>\nReturn time to cyclic task: 11\u03bcs or 8 \u03bcs *<br \/>\n*When High-speed interrupt function is used<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Scheduled<br \/>\nInterrupts<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Interrupt task startup time: 22 \u03bcs or 13 \u03bcs *<br \/>\nReturn time to cyclic task: 11 \u03bcs or 8 \u03bcs *<br \/>\n*When High-speed interrupt function is used<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Maximum Number of Connectable Units<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Total per CPU Rack or Expansion Rack: 10 Units max.;<br \/>\nTotal per PLC: 40 Units max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Maximum Number of Expansion Racks<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">3 max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"7\"><strong>CIO Area<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2,560 bits (160 words): Words CIO 0000 to CIO 0159<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Link Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">3,200 bits (200 words): Words CIO 1000 to CIO 1199<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Synchronous Data Refresh Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">1,536 bits (96 words): Words CIO 1200 to CIO 1295<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CPU Bus Unit Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">6,400 bits (400 words): Words CIO 1500 to CIO 1899<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Special I\/O Unit Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">15,360 bits (960 words): Words CIO 2000 to CIO 2959<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>DeviceNet Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">9,600 bits (600 words): Words CIO 3200 to CIO 3799<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Internal I\/O Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">3,200 bits (200 words): Words CIO 1300 to CIO 1499<br \/>\n37,504 bits (2,344 words): Words CIO 3800 to CIO 6143<br \/>\nCannot be used for external I\/O.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Work Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">8,192 bits (512 words): Words W000 to W511<br \/>\nCannot be used for external I\/O.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Holding Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">8,192 bits (512 words): Words H000 to H511<br \/>\nBits in this area maintain their ON\/OFF status when PLC is turned<br \/>\nOFF or operating mode is changed.<br \/>\nWords H512 to H1535: These words can be used only for function<br \/>\nblocks. They can be used only for function block instances (i.e.,<br \/>\nthey are allocated only for internal variables in function blocks).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Auxiliary Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Read-only: 31,744 bits (1,984 words)<br \/>\n7,168 bits (448 words): Words A0 to A447<br \/>\n24,576 bits (1,536 words): Words A10000 to A11535 *<br \/>\nRead\/write: 16,384 bits (1,024 words) in words A448 to A1471 *<br \/>\n*A960 to A1471 and A10000 to A11535 cannot be accessed by<br \/>\nCPU Bus Units, Special I\/O Units, PTs, and Support Software that<br \/>\ndo not specifically support the CJ2 CPU Units.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Temporary Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">16 bits: TR0 to TR15<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Timer Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">4,096 timer numbers (T0000 to T4095 (separate from counters))<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Counter Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">4,096 counter numbers (C0000 to C4095 (separate from timers))<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>DM Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">32k words *<br \/>\nDM Area words for Special I\/O Units: D20000 to D29599 (100 words<br \/>\n\u00d7 96 Units)<br \/>\nDM Area words for CPU Bus Units: D30000 to D31599 (100 words<br \/>\n\u00d7 16 Units)<br \/>\n*Bits in the EM Area can be addressed either by bit or by word.<br \/>\nThese bits cannot be addressed by CPU Bus Units, Special I\/O<br \/>\nUnits, PTs, and Support Software that do not specifically support<br \/>\nthe CJ2 CPU Units.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"2\"><strong>EM Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">32k words\/bank \u00d7 25 banks max.: E00_00000 to E18_32767 max.<br \/>\n*1 *2<br \/>\n*1. Bits in the EM Area can be addressed either by bit or by word.<br \/>\nThese bits cannot be addressed by CPU Bus Units, Special I\/O<br \/>\nUnits, PTs, and Support Software that do not specifically support<br \/>\nthe CJ2 CPU Units.<br \/>\n*2. EM banks D to 18 cannot be accessed by CPU Bus Units,<br \/>\nSpecial I\/O Units, PTs, and Support Software that do not<br \/>\nspecifically support the CJ2 CPU Units.<br \/>\n*3. Force-set\/reset to the EM Area is enabled by specifying a<br \/>\nstart bank in parameter settings. (unit version 1.2 or higher)<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">32K words<br \/>\n\u00d7 4 banks<\/td>\n<td class=\"left middle\">32K words<br \/>\n\u00d7 4 banks<\/td>\n<td class=\"left middle\">32K words<br \/>\n\u00d7 10 banks<\/td>\n<td class=\"left middle\">32K words<br \/>\n\u00d7 15 banks<\/td>\n<td class=\"left middle\">32K words<br \/>\n\u00d7 25 banks<\/td>\n<\/tr>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><\/th>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Force-S\/R<br \/>\nEnabled<br \/>\nBanks<\/strong><\/th>\n<th class=\"heading left middle\"><strong>When EM force-S\/R<br \/>\nfunction is used *3<\/strong><\/th>\n<td class=\"left middle\">Bank 0 to 3<\/td>\n<td class=\"left middle\">Bank 0 to 3<\/td>\n<td class=\"left middle\">Bank 0 to 9<\/td>\n<td class=\"left middle\">Bank 0 to E<\/td>\n<td class=\"left middle\">Bank 0 to 18<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>When automatic<br \/>\naddress allocation<br \/>\nis specified<\/strong><\/th>\n<td class=\"left middle\">Bank 3<\/td>\n<td class=\"left middle\">Bank 3<\/td>\n<td class=\"left middle\">Bank 6 to 9<\/td>\n<td class=\"left middle\">Bank 7 to E<\/td>\n<td class=\"left middle\">Bank 11 to 18<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Index Registers<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">IR0 to IR15<br \/>\nThese are special registers for storing PLC memory addresses for<br \/>\nindirect addressing. (Index Registers can be set so that they are<br \/>\nunique in each task or so that they are shared by all tasks.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Cyclic Task Flag Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">128 flags<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Memory Card<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">128 MB, 256 MB, or 512 MB<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Operating Modes<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">PROGRAM Mode: Programs are not executed. Preparations can be<br \/>\nexecuted prior to program execution in this mode.<br \/>\nMONITOR Mode: Programs are executed, and some operations,<br \/>\nsuch as online editing, and changes to present values in I\/O<br \/>\nmemory, are enabled in this mode.<br \/>\nRUN Mode: Programs are executed. This is the normal operating<br \/>\nmode.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Execution Mode<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Normal Mode<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Programming Languages<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Ladder Logic (LD),<br \/>\nSequential Function Charts (SFC),<br \/>\nStructured Text (ST), and<br \/>\nInstruction Lists (IL)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Function<br \/>\nBlocks<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Maximum number of definitions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2,048<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Maximum number of instances<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2,048<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Tasks<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Type of Tasks<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Cyclic tasks<br \/>\nInterrupt tasks (Power OFF interrupt tasks, scheduled interrupt<br \/>\ntasks, I\/O interrupt tasks, and external interrupt tasks)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of Tasks<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Cyclic tasks: 128<br \/>\nInterrupt tasks: 256<br \/>\n(Interrupt tasks can be defined as cyclic tasks to create extra<br \/>\ncyclic tasks. Therefore, the total number of cyclic tasks is actually<br \/>\n384 max.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><strong>Symbols<br \/>\n(Variables)<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Type of Symbols<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Local symbols: Can be used only within a single task in the PLC.<br \/>\nGlobal symbols: Can be used in all tasks in the PLC.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Data Type of Symbols<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">BOOL (bit)<br \/>\nUINT (one-word unsigned binary)<br \/>\nUDINT (two-word unsigned binary)<br \/>\nULINT (four-word unsigned binary)<br \/>\nINT (one-word signed binary)<br \/>\nDINT (two-word signed binary)<br \/>\nLINT (four-word signed binary)<br \/>\nUINT BCD (one-word unsigned BCD) *1<br \/>\nUDINT BCD (two-word unsigned BCD) *1<br \/>\nULINT BCD (four-word unsigned BCD) *1<br \/>\nREAL (two-word floating-point)<br \/>\nLREAL (four-word floating-point)<br \/>\nCHANNEL (word) *1<br \/>\nNUMBER (constant or number) *1<br \/>\nWORD (one-word hexadecimal)<br \/>\nDWORD (two-word hexadecimal)<br \/>\nLWORD (four-word hexadecimal)<br \/>\nSTRING (1 to 255 ASCII characters)<br \/>\nTIMER (timer) *2<br \/>\nCOUNTER (counter) *2<br \/>\nUser defined data types (data structures) *3<br \/>\n*1. Cannot be used in Function blocks<br \/>\n*2. Can be used only in Function blocks<br \/>\n*3. Supported only when CX-Programmer version 9.0 or later is<br \/>\nused<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Maximum Size of Symbol<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">32k words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Array Symbols (Array<br \/>\nVariables)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">One-dimensional arrays<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of Array Elements<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">32,000 elements max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Data<br \/>\nTracing<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"2\"><strong>Memory Capacity<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">8,000 words<\/td>\n<td class=\"left middle\">16,000 words<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">32,000 words<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">(The EM Area can be specified from the CX-Programmer to use up<br \/>\nto 32K words multiplied by the number of banks supported by the<br \/>\nCPU Unit model.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of Samplings<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Bits = 31, one-word data =16, two-word data = 8,<br \/>\nfour-word data = 4<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Sampling Cycle<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">1 to 2,550 ms (Unit: 1 ms)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Trigger Conditions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">ON\/OFF of specified bit<br \/>\nData comparison of specified word<br \/>\nData size: 1 word, 2 words, 4 words<br \/>\nComparison Method: Equals (=), Greater Than (&gt;), Greater Than or<br \/>\nEquals (\u2265), Less Than (&lt;), Less Than or Equals (\u2264), Not Equal (\u2260)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Delay Value<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">&#8211; 32,768 to +32,767 ms<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>File Memory<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Memory Card (128, 256, or 512 Mbytes) (Use the Memory Cards<br \/>\nprovided by OMRON.)<br \/>\nEM file memory (Part of the EM Area can be converted for use as<br \/>\nfile memory.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Source\/<br \/>\nComment<br \/>\nMemory<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Program sources, comments,<br \/>\nprogram indexes, symbol tables<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Capacity: 3.5 Mbytes<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"12\"><strong>Com-<br \/>\nmuni-<br \/>\ncations<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Logical<br \/>\nPorts for<br \/>\nCommuni-<br \/>\ncations<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Logical Ports<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">8 ports (Used for SEND, RECV, CMND, PMCR, TXDU, and RXDU<br \/>\ninstructions.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Extended Logical<br \/>\nPorts<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">64 ports (Used for SEND2, RECV2, CMND2, and PMCR2<br \/>\ninstructions.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>CIP<br \/>\nCommuni-<br \/>\ncations<br \/>\nSpec-<br \/>\nification<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Class 3 Connection<br \/>\nType<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Number of connections: 64<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>UCMM (Non-<br \/>\nconnection Type)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Maximum number of clients that can communicate at the same<br \/>\ntime: 32<br \/>\nMaximum number of servers that can communicate at the same<br \/>\ntime: 40<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Peripheral (USB) Port<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">USB 2.0-compliant B-type connector<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><\/th>\n<th class=\"heading left middle\"><strong>Baud Rate<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">12 Mbps max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission<br \/>\nDistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">5 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Serial Port<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Interface: Conforms to EIA RS-232C.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><\/th>\n<th class=\"heading left middle\"><strong>Communications<br \/>\nMethod<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Half-duplex<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Synchronization<br \/>\nMethod<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Start-stop<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Baud Rate<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 (kbps)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission<br \/>\nDistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">15 m max.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Function Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Functions<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Description<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Cycle<br \/>\nTime<br \/>\nMan-<br \/>\nagement<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Minimum Cycle Time<\/strong><\/th>\n<td class=\"left middle\">A minimum cycle time can be set.<br \/>\n(0.2 to 32,000 ms; Unit: 0.1 ms)<br \/>\nThe minimum cycle time setting can be changed in MONITOR mode.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Cycle Time Monitoring<\/strong><\/th>\n<td class=\"left middle\">The cycle time is monitored.<br \/>\n(0.01 to 40,000 ms; Unit: 0.01 ms)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Background Processing<\/strong><\/th>\n<td class=\"left middle\">Instructions with long execution times can be executed over multiple cycles to prevent fluctuations in the cycle time.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"12\"><strong>Unit (I\/O)<br \/>\nMan-<br \/>\nagement<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Basic I\/O<br \/>\nUnits,<br \/>\nSpecial<br \/>\nI\/O Units,<br \/>\nand CPU<br \/>\nBus Units<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>I\/O<br \/>\nRefreshing<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Cyclic<br \/>\nRefreshing<\/strong><\/th>\n<td class=\"left middle\">Cyclic refreshing of Basic I\/O Units, Special I\/O Units, and CPU Bus Units<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Immediate<br \/>\nRefreshing<\/strong><\/th>\n<td class=\"left middle\">I\/O refreshing by immediate refreshing instructions<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Refreshing<br \/>\nby IORF<\/strong><\/th>\n<td class=\"left middle\">I\/O refreshing by IORF instruction<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Unit Recognition at Startup<\/strong><\/th>\n<td class=\"left middle\">The number of units recognized when the power is turned ON is displayed.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Basic I\/O<br \/>\nUnits<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Input Response Time Setting<\/strong><\/th>\n<td class=\"left middle\">The input response times can be set for Basic I\/O Units. The response time can be increased to reduce the effects of chattering and noise at input contacts. The response time can be decreased to enable detecting shorter input pulses.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Load OFF Function<\/strong><\/th>\n<td class=\"left middle\">All of the outputs on Basic I\/O Units can be turned OFF when an error occurs in RUN or MONITOR mode.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Basic I\/O Unit Status<br \/>\nMonitoring<\/strong><\/th>\n<td class=\"left middle\">Alarm information can be read from Basic I\/O Units and the number of Units recognized can be read.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Special<br \/>\nI\/O Units<br \/>\nand CPU<br \/>\nBus Units<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Unit Restart Bits to Restart<br \/>\nUnits<\/strong><\/th>\n<td class=\"left middle\">A Special I\/O Unit or CPU Bus Unit can be restarted.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Synchronous Unit Operation<\/strong><\/th>\n<td class=\"left middle\">The start of processing for all the specified Units can be synchronized at a fixed interval.<br \/>\nMaximum number of Units: 10 Units<br \/>\n(Only Units that support Synchronous Operation Mode can be used.)<br \/>\nSynchronous operation cycle: 0.5 to 10ms (default: 2 ms)<br \/>\nMaximum number of words for synchronous data refreshing: 96 words (total of all Units)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Con-<br \/>\nfiguration<br \/>\nMan-<br \/>\nagement<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Automatic I\/O Allocation at<br \/>\nStartup<\/strong><\/th>\n<td class=\"left middle\">I\/O words can be automatically allocated to the Basic I\/O Units that are connected in the PLC to start operation automatically without registering Units into I\/O tables.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O Table Creation<\/strong><\/th>\n<td class=\"left middle\">The current unit configuration can be registered in I\/O tables to prevent it from being changed, to reserve words, and to set words.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Rack\/Slot First Word Settings<\/strong><\/th>\n<td class=\"left middle\">The first words allocated to a Units on the Racks can be set.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Memory<br \/>\nMan-<br \/>\nagement<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Holding I\/O Memory when Changing<br \/>\nOperating Modes<\/strong><\/th>\n<td class=\"left middle\">The status of I\/O memory can be held when the operating mode is changed or power is turned ON. The forced-set\/reset status can be held when the operating mode is changed or power is turned ON.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>File Memory<\/strong><\/th>\n<td class=\"left middle\">Files (such as program files, data files, and symbol table files) can be stored in Memory Card, EM File Memory, or Comment Memory.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Built-in Flash Memory<\/strong><\/th>\n<td class=\"left middle\">The user program and Parameter Area can be backed up to an internal flash memory when they are transferred to the CPU Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>EM File Function<\/strong><\/th>\n<td class=\"left middle\">Parts of the EM Area can be treated as file memory.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Storing Comments<\/strong><\/th>\n<td class=\"left middle\">I\/O comments can be stored as symbol table files in a Memory Card, EM file memory, or comment memory.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>EM Configuration<\/strong><\/th>\n<td class=\"left middle\">EM Area can be set as trace memory or EM file memory.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Memory<br \/>\nCards<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Automatic File Transfer at Startup<\/strong><\/th>\n<td class=\"left middle\">A program file and parameter files can be read from a Memory Card when the power is turned ON.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Program Replacement during PLC Operation<\/strong><\/th>\n<td class=\"left middle\">The whole user program can be read from a Memory Card to CPU Unit during operation.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Function for Reading and Writing Data<br \/>\nfrom a Memory Card<\/strong><\/th>\n<td class=\"left middle\">Data in I\/O memory in the CPU Unit can be written to a Memory Card in CSV\/TXT format. Data in CSV\/TXT format in the Memory Card can be read to I\/O memory in the CPU Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Communications<\/strong><\/th>\n<td class=\"center middle\">&#8212;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"7\"><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Peripheral (USB) Port<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Peripheral Bus<\/strong><\/th>\n<td class=\"left middle\">Bus for communications with various kinds of Support Software running on a personal computer. High-speed communications are supported.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Serial Port<\/strong><\/th>\n<td class=\"center middle\">&#8212;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Host Link (SYSWAY)<br \/>\nCommunications<\/strong><\/th>\n<td class=\"left middle\">Host Link commands or FINS commands placed between Host Link headers and terminators can be sent from a host computer or PT to read\/write I\/O memory, read\/control the operating mode, and perform other operations for PLC.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>No-protocol<br \/>\nCommunications<\/strong><\/th>\n<td class=\"left middle\">I\/O instructions for communications ports (such as TXD\/RXD instructions) can be used for data transfer with peripheral devices such as bar code readers and printers.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>NT Link Communications<\/strong><\/th>\n<td class=\"left middle\">I\/O memory in the PLC can be allocated and directly linked to various PT functions, including status control areas, status notification areas, touch switches, lamps, memory tables, and other objects.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Peripheral Bus<\/strong><\/th>\n<td class=\"left middle\">Bus for communications with various kinds of Support Software running on a personal computer. High-speed communications are supported.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Serial Gateway<\/strong><\/th>\n<td class=\"left middle\">This gateway enables receiving and automatically converting FINS to the CompoWay\/F.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><strong>Interrupt<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Scheduled Interrupts<\/strong><\/th>\n<td class=\"left middle\">Tasks can be executed at a specified interval (minimum of 0.2 ms or 0.1 ms * , Unit: 0.1 ms).<br \/>\n* When High-speed interrupt function is used.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Power OFF Interrupts<\/strong><\/th>\n<td class=\"left middle\">A task can be executed when CPU Unit&#8217;s power turns OFF.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>I\/O Interrupt Tasks<\/strong><\/th>\n<td class=\"left middle\">A task can be executed when an input signal is input to an Interrupt Input Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>External Interrupt Tasks<\/strong><\/th>\n<td class=\"left middle\">A task can be executed when interrupts are requested from a Special I\/O Unit or a CPU Bus Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>High-speed Interrupt Function<\/strong><\/th>\n<td class=\"left middle\">Improves performance for executing interrupt tasks with certain restrictions.<br \/>\n(Unit version 1.1 or later.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"9\"><strong>Clock<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Clock Function<\/strong><\/th>\n<td class=\"left middle\">Cock data is stored in memory.<br \/>\nAccuracy (Accuracy depends on the temperature.)<br \/>\nAmbient temperature of 55 \u00b0C: &#8211; 3.5 to +0.5 min error per month<br \/>\nAmbient temperature of 25 \u00b0C: &#8211; 1.5 to +1.5 min error per month<br \/>\nAmbient temperature of 0 \u00b0C: &#8211; 3 to +1 min error per month<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Operation Start Time Storage<\/strong><\/th>\n<td class=\"left middle\">The time when operating mode was last changed to RUN mode or MONITOR mode is stored.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Operation Stop Time Storage<\/strong><\/th>\n<td class=\"left middle\">The last time a fatal error occurred or the last time the operating mode was changed to PROGRAM mode is stored.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Startup Time Storage<\/strong><\/th>\n<td class=\"left middle\">The time when the power was turned ON is stored.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Power Interruption Time Storage<\/strong><\/th>\n<td class=\"left middle\">The time when the power is turned OFF is stored.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Total Power ON Time Calculation<\/strong><\/th>\n<td class=\"left middle\">The total time that the PLC has been ON is stored in increments of 10 hours.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Power ON Clock Data Storage<\/strong><\/th>\n<td class=\"left middle\">A history of the times when the power was turned ON is stored.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>User Program Overwritten Time Storage<\/strong><\/th>\n<td class=\"left middle\">The time that the user program was last overwritten is stored.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Parameter Date Storage<\/strong><\/th>\n<td class=\"left middle\">The time when the Parameter Area was overwritten is stored.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Power<br \/>\nSupply<br \/>\nMan-<br \/>\nagement<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Memory Protection<\/strong><\/th>\n<td class=\"left middle\">Holding Area data, DM Area data, EM Area data, Counter Completion Flags, and counter present values are held even when power is turned OFF. CIO Area, Work Area, some Auxiliary Area data, and Timer Completion Flags, timer present values, index registers, and data registers can be protected by turning ON the IOM Hold Bit in the Auxiliary Area, and by also setting the IOM Hold Bit to &#8220;Hold&#8221; in the PLC Setup.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Power OFF Detection Time Setting<\/strong><\/th>\n<td class=\"left middle\">The detection time for power interruptions can be set.<br \/>\nAC power supply: 10 to 25 ms (variable)<br \/>\nDC power supply: 2 to 5 ms (CJ1W-PD022) or 2 to 20 ms (CJ1W-PD025)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Power OFF Detection Delay Time<\/strong><\/th>\n<td class=\"left middle\">The detection of power interruptions can be delayed: 0 to 10 ms<br \/>\n(Not supported by the CJ1W-PD022.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Number of Power Interruptions Counter<\/strong><\/th>\n<td class=\"left middle\">The number of times power has been interrupted is counted.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Function Blocks<\/strong><\/th>\n<td class=\"left middle\">Standard programming can be encapsulated as function blocks.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Languages in Function Block Definitions<\/strong><\/th>\n<td class=\"left middle\">Ladder programming or structured text<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Debugging<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Online Editing<\/strong><\/th>\n<td class=\"left middle\">The program can be changed during operation (in MONITOR or PROGRAM mode), except for block programming areas.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Force-Set\/Reset<\/strong><\/th>\n<td class=\"left middle\">Specified bits can be set or reset.<br \/>\nForce-set\/reset to the EM Area is enabled by specifying a start bank in parameter setting. (unit version 1.2 or higher)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Differentiate Monitoring<\/strong><\/th>\n<td class=\"left middle\">ON\/OFF changes in specified bits can be monitored.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Data Tracing<\/strong><\/th>\n<td class=\"left middle\">The specified I\/O memory data can be stored in the trace memory in the CPU Unit. The triggers can be set.<br \/>\nThe trace data can be uploaded during data tracing using CX-Programmer, which enables continuously logging the data by constantly uploading the trace data (trace data uploading during tracing).<br \/>\nData tracing can be automatically started when operation is started (i.e., when the operating mode is changed from PROGRAM mode to MONITOR or RUN mode).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Storing Location of Error when an Error<br \/>\nOccurs<\/strong><\/th>\n<td class=\"left middle\">The location and task number where execution stopped for a program error is recorded.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Program Check<\/strong><\/th>\n<td class=\"left middle\">The programs can be checked for items such as no END instruction and FALS\/FAL errors at startup.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"37\"><strong>Self-<br \/>\ndiagnosis<br \/>\nand<br \/>\nRes-<br \/>\ntoration<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Error Log<\/strong><\/th>\n<td class=\"left middle\">A function is provided to store predefined error codes in CPU Unit, error information, and time at which the error occurred.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>CPU Error Detection<\/strong><\/th>\n<td class=\"left middle\">CPU Unit WDT errors are detected.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>User-defined Failure Diagnosis<\/strong><\/th>\n<td class=\"left middle\">Errors can be generated for user-specified conditions: Non-fatal errors (FAL) and fatal errors (FALS).<br \/>\nProgram section time diagnosis and program section logic diagnosis are supported (FPD instruction).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Load OFF Function<\/strong><\/th>\n<td class=\"left middle\">This function turns OFF all outputs from Output Units when an error occurs.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>RUN Output<\/strong><\/th>\n<td class=\"left middle\">The RUN output from the CJ1W-PA205R turns ON while CPU Unit is in RUN mode or MONITOR mode.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Basic I\/O Load Short-circuit Detection<\/strong><\/th>\n<td class=\"left middle\">This function provides alarm information from Basic I\/O Units that have load short-circuit protection.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Failure Point Detection<\/strong><\/th>\n<td class=\"left middle\">The time and logic of an instruction block can be analyzes using the FPD instruction.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>CPU Standby Detection<\/strong><\/th>\n<td class=\"left middle\">This function indicates when the CPU Unit is on standby because all Special I\/O Units and CPU Bus Units have not been recognized at the startup in RUN or MONITOR mode.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"10\"><strong>Non-fatal<br \/>\nError<br \/>\nDetection<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>System FAL Error Detection<br \/>\n(User-defined non-fatal<br \/>\nerror)<\/strong><\/th>\n<td class=\"left middle\">This function generates a non-fatal (FAL) error when the user-defined conditions are met in program.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Duplicate Refreshing Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when an immediate refreshing Instruction in an interrupt task is competing with I\/O refreshing of a cyclic task.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Basic I\/O Unit Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects the errors in Basic I\/O Units.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Backup Memory Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects errors in the memory backup of the user programs and parameter area (backup memory).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>PLC Setup Error Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects setting errors in the PLC Setup.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CPU Bus Unit Error Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when there is an error in data exchange between the CPU Unit and a CPU Bus Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Special I\/O Unit Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when there is an error in data exchange between the CPU Unit and a Special I\/O Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Battery Error Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when a battery is not connected to the CPU Unit or when the battery voltage drops.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CPU Bus Unit Setting Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when the model of a CPU Bus Unit in the registered I\/O tables does not agree with the model that is actually mounted in the PLC.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Special I\/O Unit Setting Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when the model of a Special I\/O Unit in the registered I\/O tables does not agree with the model of Unit that is actually mounted.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"18\"><strong>Fatal Error<br \/>\nDetection<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Memory Error Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects errors that occur in memory of the CPU Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O Bus Error Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects when an error occurs in data transfers between the Units mounted in Rack slots and the CPU Unit and detects when the End Cover is not connected to the CPU Rack or an Expansion Rack.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Unit\/Rack Number<br \/>\nDuplication Error<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when the same unit number is set for two or more Units, the same word is allocated to two or more Basic I\/O Units, or the same rack number is set for two or more Racks.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Too Many I\/O Points Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when the total number of I\/O points set in the I\/O tables or the number of Units per Rack exceeds the specified range.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O Setting Error Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when the number of Units in the registered I\/O tables does not agree with the actual number of Units that is mounted, or an Interrupt Unit has been connected in the wrong position, i.e., not in slot 0 to 4.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Program Error Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects errors in programs.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"8\"><\/th>\n<th class=\"heading left middle\"><strong>Instruction<br \/>\nProcessing<br \/>\nError Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when the given data value is invalid when executing an instruction, or execution of instruction between tasks was attempted.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Indirect DM\/EM<br \/>\nBCD Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when an indirect DM\/EM address in BCD mode is not BCD.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Illegal Area<br \/>\nAccess Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when an attempt is made to access an illegal area with an instruction operand.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>No END Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when there is no END instruction at the end of the program.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Task Error Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when there are no tasks that can be executed in a cycle, there is no program for a task, or the execution condition for an interrupt task was met but there is no interrupt task with the specified number.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Differentiation<br \/>\nOverflow Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when too many differentiated instructions are entered or deleted during online editing (131,072 times or more).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Invalid<br \/>\nInstruction<br \/>\nError Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when an attempt is made to execute an instruction that is not defined in the system.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>User Program<br \/>\nArea Overflow<br \/>\nError Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when instruction data is stored after the last address in user program area.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Cycle Time Exceeded Error<br \/>\nDetection<\/strong><\/th>\n<td class=\"left middle\">This function monitors the cycle time (10 to 40,000 ms) and stops the operation when the set value is exceeded.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>System FALS Error Detection<br \/>\n(User-defined Fatal Error)<\/strong><\/th>\n<td class=\"left middle\">This function generates a fatal (FALS) error when the user-defined conditions are met in program.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Version Error Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when a user program includes a function that is not supported by the current unit version.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Memory Card Transfer Error Detection<\/strong><\/th>\n<td class=\"left middle\">This function detects an error when the automatic file transfer from Memory Card fails at startup.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Memory Self-restoration Function<\/strong><\/th>\n<td class=\"left middle\">This function performs a parity check on the user program area and self-restoration data.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Main-<br \/>\ntenance<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Simple Backup Function<\/strong><\/th>\n<td class=\"left middle\">This function collectively backs up the data in CPU Unit (user programs, parameters, and I\/O memory) and internal backup data in the I\/O Units.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Unsolicited Communications<\/strong><\/th>\n<td class=\"left middle\">A function that allows the PLC to use Network Communications Instruction to send required FINS commands to a computer connected via a Host Link<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Remote Programming and Monitoring<\/strong><\/th>\n<td class=\"left middle\">Host Link communications can be used for remote programming and remote monitoring through a Controller Link, Ethernet, DeviceNet, or SYSMAC LINK Network. Communications across network layers can be performed.<br \/>\nController Link or Ethernet: 8 layers<br \/>\nDeviceNet or SYSMAC LINK: 3 layers<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Automatic Online<br \/>\nConnection via Network<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Direct Serial<br \/>\nConnection<\/strong><\/th>\n<td class=\"left middle\">This function enables automatically connecting to the PLC online when the CX-Programmer is directly connected by a serial connection (peripheral (USB) port or serial port).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Security<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Read Protection using Password<\/strong><\/th>\n<td class=\"left middle\">This function protects reading and displaying programs and tasks using passwords.<br \/>\nWrite protection: Set using the DIP switch.<br \/>\nRead protection: Set a password using the CX-Programmer.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>FINS Write Protection<\/strong><\/th>\n<td class=\"left middle\">This function prohibits writing by using FINS commands sent over the network.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Unit Name Function<\/strong><\/th>\n<td class=\"left middle\">This function allows the users to give any names to the Units. Names are verified at online connection to prevent wrong connection<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Hardware ID Using Lot Numbers<\/strong><\/th>\n<td class=\"left middle\">This function sets operation protection by identifying hardware using the user programs according to lot numbers stored in the Auxiliary Area.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CJ2H CPU Unit<br \/>\nCJ2H-CPU6[]<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/2045_dm_113-108869.gif\" alt=\"CJ2H-CPU6[] Dimensions 1 \" \/><\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj2h-cpu_ds_e_9_2_csm2011.pdf?id=2045\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CJ2H-CPU6[] Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[594KB]<\/span><\/td>\n<td class=\"td_date\">Dec 03, 2018<\/td>\n<\/tr>\n<tr class=\"even\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj2h_cj2m_p059-e1_17_7_csm1004123.pdf?id=2045\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CJ2 Catalog<\/a><\/td>\n<td>P059-E1-11<br \/>\n<span class=\"file-size\">[14188KB]<\/span><\/td>\n<td class=\"td_date\">Dec 17, 2018<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cs_cj_cp_p097-e1-01.pdf?id=2045\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0New Functions Added to CS\/CJ\/CP Series Catalog<\/a><\/td>\n<td>P097-E1-01<br \/>\n<span class=\"file-size\">[1267KB]<\/span><\/td>\n<td class=\"td_date\">Sep 28, 2015<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">Small, Fast, Flexible: Inheriting and improving CJ1 features, the CJ2 CPU Units is the best choice for the machine control with high-speed and high-capacity.<\/h2>\n","protected":false},"featured_media":1561,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[91,63,72],"product_tag":[],"_links":{"self":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product\/1565"}],"collection":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/comments?post=1565"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media\/1561"}],"wp:attachment":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media?parent=1565"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1565"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1565"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}