{"id":1564,"date":"2019-01-03T09:25:07","date_gmt":"2019-01-03T09:25:07","guid":{"rendered":"http:\/\/store.al-tet.com\/?post_type=product&#038;p=1564"},"modified":"2019-01-03T09:25:14","modified_gmt":"2019-01-03T09:25:14","slug":"cj2h-cpu6-eip","status":"publish","type":"product","link":"http:\/\/store.al-tet.com\/index.php\/product\/cj2h-cpu6-eip\/","title":{"rendered":"CJ2H-CPU6[]-EIP"},"content":{"rendered":"<h4 class=\"heading-A01\">Global Standard<\/h4>\n<h4 class=\"heading-A02\">Highly Open Global Standard for FA Industry with High Future Potential<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>The ODVA promotes the spread of Industrial Ethernet all over the world.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>EtherNet\/IP can be used to communicate with many devices from various companies around the world in addition to OMRON components (such as Temperature Controllers and Sensors). The use of EtherNet\/IP will rapidly increase the development of an EtherNet\/IP multivendor environment (including robots and safety devices).<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_113-108453.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 3 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">Integrated Information and Control Network<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Seamless communications on the control line and information monitoring line with EtherNet\/IP<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Using the global standard open protocol (CIP), an independent network system can be created with seamless data flow between the control line and the information monitoring line.<br \/>\nOMRON FINS message communications can also be used on the same network because it is a standard LAN.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_213-108455.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 5 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">Improved operation efficiency with common Support Software operation<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Use the same operating procedures for both EtherNet\/IP and DeviceNet Support Software.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The same Support Software procedures can be used from a remote location for device configuration, monitoring, and program transfer for the DeviceNet and EtherNet\/IP networks.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_313-108457.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 7 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">Monitor Safety Systems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Safety systems can be monitored through the EtherNet\/IP.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The safety system can be monitored from a PLC by using a modular designed Safety Control Unit with a EtherNet\/IP Coupler Unit.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_413-108459.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 9 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A01\">Convenience of the Universal Ethernet Right in Your Hands<\/h4>\n<h4 class=\"heading-A02\">Higher Data Link Capacity (9 times the capacity of previous OMRON models)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>High-capacity communications with high-speed high-capacity bus<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>All types of data, from process interlocks and manufacturing recipes to production data, can be exchanged at high speed and with optimal timing. The ability to communicate is incomparably better than previous networks, such as the Controller Link and FL-net.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_513-108461.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 13 \" \/><\/div>\n<div class=\"text\">\n<p>Note: Using a built-in EtherNet\/IP port on CJ2H and EtherNet\/IP Units.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Low Cost Expansion for Each Line<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Flexible topology with the Ethernet switch<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Flexible wiring and expansion are possible with Ethernet switches. This means that there will be no total network crashes caused by communications path errors, ensuring high network performance and security.<\/p>\n<p>&#8211; Joining and leaving the network is possible during communications.<\/p>\n<p>Nodes can leave the network during operation, enabling easy maintenance for error detection, separation, and restoration.<\/p>\n<p>&#8211; Unpredictable delays caused by data collisions are minimum.<br \/>\n&#8211; Problems caused by wiring errors are minimized to each line.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_613-108463.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 16 \" \/><\/div>\n<div class=\"text\">\n<p>Star topology using Ethernet switch technology<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Reduced Network Facility and Wiring Costs<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Generic LAN cables can be used.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>&#8211; Metal cables of category 5, 5e, or higher can be used as LAN cables.<br \/>\n&#8211; Generic RJ-45 connectors can be used.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Standard wireless LAN can be used because EtherNet\/IP is also Universal Ethernet.<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>There is no need to rewire even when layout has been changed.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>&#8211; EtherNet\/IP can be made wireless using the standard wireless LAN.<br \/>\n&#8211; High-speed Smart Roaming communications can be used for mobile units with the WE70 FA Wireless LAN. The communications range can be expanded by relaying communications between access points.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_713-108465.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 20 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A01\">Integration of Control and Information Networks<\/h4>\n<h4 class=\"heading-A02\">High-speed Data Links with Optimal Cycles for Applications (30 times higher than previous OMRON models)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Flexible and high-speed cyclic communications<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>&#8211; Grouping can be used in data link tables to create multiple sections.<\/p>\n<p>Data link table can be divided into up to 256 groups (= connections).<br \/>\nThe optimum communications cycle for the application can be set for each group.<\/p>\n<p>&#8211; Cyclic synchronization can be set for each group.<\/p>\n<p>The communications cycle can be set to between 0.5 ms and 10 s in 0.5-ms increments. Data concurrency is maintained for each connection. The communications cycle does not change even if the number of nodes increases. The communications performance is 30 times better than that of the Controller Link.<br \/>\nExample:<br \/>\nData link refresh cycle for 25 linked Unit and 20,000 words\/network is reduced from 300 ms to 10 ms.<\/p>\n<p>&#8211; Facilities can be easily expanded.<\/p>\n<p>When expanding facilities, all you need to do is make additions to the tables. Expansion is possible with little time and low cost.<br \/>\nNote: Using a built-in EtherNet\/IP port on CJ2H and EtherNet\/IP Units.<\/p><\/div>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_813-108467.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 23 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">FTP, Data Links, and Support Software Can Be Used Simultaneously with One Port<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>With the multipurpose EtherNet\/IP port, an Ethernet Unit is not required for expansion.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Using the multipurpose EtherNet\/IP port built into a CJ\/NJ\/NX\/NY CPU Unit, a single port can be used for data link communications between PLCs, messages between PLCs, and Universal Ethernet communications, such as FTP transfers while connecting Support Software. An EtherNet\/IP Unit can be added to any CS\/CJ-series PLC to achieve the same functions.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_913-108469.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 25 \" \/><\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_1113-232812.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 26 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">Memory Map Management Becomes Unnecessary.<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Freed from memory map by tags<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The transmission\/reception area can be specified with normal names called tag names instead of addresses for communication on data links between devices or when communication with the host application.<br \/>\nThe efficiency of design, startup, maintenance, and upgrading are improved.<\/p>\n<p>&#8211; PT and host applications can be developed in parallel.<\/p>\n<p>Network symbols defined in CJ\/NJ\/NX\/NY CPU Units can be used as tags when designing the PT screen.<br \/>\nDesign is easy: Just decide on the tag names for the information and control departments.<br \/>\nChanges to allocated addresses is not needed later in development.<\/p>\n<p>&#8211; Easier facility upgrading and maintenance<\/p>\n<p>Even if physical addresses change in the PLC, there is no need to make any changes in the data link settings, in the PT, or in the host application.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1993_fe_1013-108471.jpg\" alt=\"CJ2H-CPU6[]-EIP Features 28 \" \/><\/div>\n<\/div>\n<div><\/div>\n<div>\n<h4 class=\"heading-B02\">Applicable standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Ask your OMRON representative for the most recent applicable standards for each model.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">CJ2H (Built-in EtherNet\/IP) CPU Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Current<br \/>\nconsumption<br \/>\n(A)<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>I\/O capacity\/<br \/>\nMountable Units<br \/>\n(Expansion Racks)<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Program<br \/>\ncapacity<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Data memory<br \/>\ncapacity<\/strong><\/th>\n<th class=\"heading center middle\"><strong>LD<br \/>\ninstruction<br \/>\nexecution<br \/>\ntime<\/strong><\/th>\n<th class=\"heading center middle\"><strong>5 V<\/strong><\/th>\n<th class=\"heading center middle\"><strong>24 V<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><strong>CJ2H<br \/>\n(Built-in<br \/>\nEtherNet\/IP)<br \/>\nCPU Units<br \/>\n<img title=\"1993_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/1993_lu_1_113-288707.gif\" alt=\"1993_lu_1_1\" \/><\/strong><\/th>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"5\">2,560 points\/<br \/>\n40 Units<br \/>\n(3 Expansion Racks<br \/>\nmax.)<\/td>\n<td class=\"center middle\">400K<br \/>\nsteps<\/td>\n<td class=\"left middle\">832K words<br \/>\nDM: 32K words<br \/>\nEM: 32K words<br \/>\n\u00d7 25 banks<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"5\">0.016 \u03bcs<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"5\">0.82<br \/>\n*<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"5\">&#8212;<\/td>\n<td class=\"left middle\"><strong>CJ2H-CPU68-EIP<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">250K<br \/>\nsteps<\/td>\n<td class=\"left middle\">512K words<br \/>\nDM: 32K words<br \/>\nEM: 32K words<br \/>\n\u00d7 15 banks<\/td>\n<td class=\"left middle\"><strong>CJ2H-CPU67-EIP<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">150K<br \/>\nsteps<\/td>\n<td class=\"left middle\">352K words<br \/>\nDM: 32K words<br \/>\nEM: 32K words<br \/>\n\u00d7 10 banks<\/td>\n<td class=\"left middle\"><strong>CJ2H-CPU66-EIP<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">100K<br \/>\nsteps<\/td>\n<td class=\"left middle\">160K words<br \/>\nDM: 32K words<br \/>\nEM: 32K words<br \/>\n\u00d7 4 banks<\/td>\n<td class=\"left middle\"><strong>CJ2H-CPU65-EIP<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">50K<br \/>\nsteps<\/td>\n<td class=\"left middle\">160K words<br \/>\nDM: 32K words<br \/>\nEM: 32K words<br \/>\n\u00d7 4 banks<\/td>\n<td class=\"left middle\"><strong>CJ2H-CPU64-EIP<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>* Add 0.15 A per Adapter when using NT-AL001 RS-232C\/RS-422A Adapters.<br \/>\nAdd 0.04 A per Adapter when using CJ1W-CIF11 RS-422A Adapters.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Accessories<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The following accessories come with CPU Unit:<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Item<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Specification<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Battery<\/strong><\/th>\n<td class=\"left middle\">CJ1W-BAT01<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>End Cover<\/strong><\/th>\n<td class=\"left middle\">CJ1W-TER01 (necessary to be mounted at the right end of CPU Rack)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>End Plate<\/strong><\/th>\n<td class=\"left middle\">PFP-M (2 pcs)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Serial Port (RS-232C) Connector<\/strong><\/th>\n<td class=\"left middle\">Connector set for serial port connection (D-SUB 9-pin male connector)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A02\">General Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"2\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>CJ2H-<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>CPU64-EIP<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU65-EIP<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU66-EIP<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU67-EIP<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU68-EIP<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Enclosure<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Mounted in a panel<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Grounding<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Less than 100 \u03a9<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CPU Rack Dimensions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">90 mm \u00d7 65 mm \u00d7 80 mm (H \u00d7 D \u00d7 W)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight *<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">280 g or less<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Current Consumption<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">5 VDC, 0.82 A<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"11\"><strong>Use<br \/>\nEnvi-<br \/>\nronment<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Ambient Operating<br \/>\nTemperature<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">0 to 55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient Operating<br \/>\nHumidity<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">10% to 90% (with no condensation)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Atmosphere<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Must be free from corrosive gases.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient Storage<br \/>\nTemperature<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">&#8211; 20 to 70 \u00b0C (excluding battery)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Altitude<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2,000 m or less<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Pollution Degree<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2 or less: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Noise Immunity<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2 kV on power supply line (Conforms to IEC 61000-4-4.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Overvoltage Category<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Category II: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EMC Immunity Level<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Zone B<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Vibration Resistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Conforms to IEC60068-2-6.<br \/>\n5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz<br \/>\nAcceleration of 9.8 m\/s<sup>2<\/sup>\u00a0for 100 min in X, Y, and Z directions (10 sweeps of 10<br \/>\nmin each = 100 min total)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Shock Resistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Conforms to IEC60068-2-27.<br \/>\n147 m\/s<sup>2<\/sup>, 3 times in X, Y, and Z directions (100 m\/s<sup>2<\/sup>\u00a0for Relay Output Units)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Battery<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Life<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">5 years at 25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Approx. 10 g<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">CJ1W-BAT01<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Applicable Standards<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Conforms to cULus, NK, LR and EC Directives.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Includes wight of end covers and battery.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Performance Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"2\"><strong>Items<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>CJ2H-<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>CPU64-EIP<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU65-EIP<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU66-EIP<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU67-EIP<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU68-EIP<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>User Memory<\/strong><\/th>\n<td class=\"left middle\">50K steps<\/td>\n<td class=\"left middle\">100K steps<\/td>\n<td class=\"left middle\">150K steps<\/td>\n<td class=\"left middle\">250K steps<\/td>\n<td class=\"left middle\">400K steps<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>I\/O Bits<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2,560 bits<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Processing<br \/>\nSpeed<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Overhead Processing Time<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Normal Mode: 200 \u03bcs<br \/>\n(If tag data links are used with EtherNet\/IP, add the following to the above time: 100 \u03bcs + Number of transferred words \u00d7 (0.33 \u03bcs or 0.87 \u03bcs *))<br \/>\nWhen High-speed interrupt function is used<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Execution Time<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Basic Instructions: 0.016 \u03bcs min.;<br \/>\nSpecial Instructions: 0.048 \u03bcs min.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Inter-<br \/>\nrupts<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>I\/O Interrupts and External<br \/>\nInterrupts<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Interrupt task startup time: 26 \u03bcs or 17 \u03bcs * (30 \u03bcs in unit Ver.1.0)<br \/>\nReturn time to cyclic task: 11 \u03bcs or 8 \u03bcs * (15 \u03bcs in unit Ver.1.0)<br \/>\n* When High-speed interrupt function is used<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Scheduled Interrupts<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Interrupt task startup time: 22 \u03bcs or 13\u03bcs * (27 \u03bcs in unit Ver.1.0)<br \/>\nReturn time to cyclic task: 11 \u03bcs or 8\u03bcs * (15 \u03bcs in unit Ver.1.0)<br \/>\n* When High-speed interrupt function is used<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Maximum Number of Connectable Units<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Total per CPU Rack or Expansion Rack: 10 Units max.;<br \/>\nTotal per PLC: 40 Units max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Maximum Number of Expansion Racks<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">3 max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"7\"><strong>CIO Area<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>I\/O Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2,560 bits (160 words): Words CIO 0000 to CIO 0159<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Link Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">3,200 bits (200 words): Words CIO 1000 to CIO 1199<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Synchronous Data Refresh Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">1,536 bits (96 words): Words CIO 1200 to CIO 1295<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>CPU Bus Unit Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">6,400 bits (400 words): Words CIO 1500 to CIO 1899<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Special I\/O Unit Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">15,360 bits (960 words): Words CIO 2000 to CIO 2959<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>DeviceNet Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">9,600 bits (600 words): Words CIO 3200 to CIO 3799<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Internal I\/O Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">3,200 bits (200 words): Words CIO 1300 to CIO 1499<br \/>\n37,504 bits (2,344 words): Words CIO 3800 to CIO 6143<br \/>\nCannot be used for external I\/O.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Work Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">8,192 bits (512 words): Words W000 to W511<br \/>\nCannot be used for external I\/O.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Holding Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">8,192 bits (512 words): Words H000 to H511<br \/>\nBits in this area maintain their ON\/OFF status when PLC is turned OFF or operating mode is changed.<br \/>\nWords H512 to H1535: These words can be used only for function blocks. They can be used only for function block instances (i.e., they are allocated only for internal variables in function blocks).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Auxiliary Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Read-only: 31,744 bits (1,984 words)<br \/>\n7,168 bits (448 words): Words A0 to A447<br \/>\n24,576 bits (1,536 words): Words A10000 to A11535 *<br \/>\nRead\/write: 16,384 bits (1,024 words) in words A448 to A1471 *<br \/>\n*A960 to A1471 and A10000 to A11535 cannot be accessed by CPU Bus Units, Special I\/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Temporary Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">16 bits: TR0 to TR15<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Timer Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">4,096 timer numbers (T0000 to T4095 (separate from counters))<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Counter Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">4,096 counter numbers (C0000 to C4095 (separate from timers))<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>DM Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">32k words *<br \/>\nDM Area words for Special I\/O Units: D20000 to D29599 (100 words \u00d7 96 Units)<br \/>\nDM Area words for CPU Bus Units: D30000 to D31599 (100 words \u00d7 16 Units)<br \/>\n*Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I\/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"2\"><strong>EM Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">32k words\/bank \u00d7 25 banks max.: E00_00000 to E18_32767 max. *1 *2<br \/>\n*1. Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I\/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.<br \/>\n*2. EM banks D to 18 cannot be accessed by CPU Bus Units, Special I\/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.<br \/>\n*3. Force-set\/reset to the EM Area is enabled by specifying a start bank in parameter settings. (unit version 1.2 or higher)<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">32K words<br \/>\n\u00d7 4 banks<\/td>\n<td class=\"left middle\">32K words<br \/>\n\u00d7 4 banks<\/td>\n<td class=\"left middle\">32K words<br \/>\n\u00d7 10 banks<\/td>\n<td class=\"left middle\">32K words<br \/>\n\u00d7 15 banks<\/td>\n<td class=\"left middle\">32K words<br \/>\n\u00d7 25 banks<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><\/th>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Force-<br \/>\nS\/R<br \/>\nEnabled<br \/>\nBanks<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>When EM force-S\/R function is<br \/>\nused *3<\/strong><\/th>\n<td class=\"left middle\">Bank 0 to 3<\/td>\n<td class=\"left middle\">Bank 0 to 3<\/td>\n<td class=\"left middle\">Bank 0 to 9<\/td>\n<td class=\"left middle\">Bank 0 to E<\/td>\n<td class=\"left middle\">Bank 0 to 18<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>When automatic address<br \/>\nallocation is specified<\/strong><\/th>\n<td class=\"left middle\">Bank 3<\/td>\n<td class=\"left middle\">Bank 3<\/td>\n<td class=\"left middle\">Bank 6 to 9<\/td>\n<td class=\"left middle\">Bank 7 to E<\/td>\n<td class=\"left middle\">Bank 11 to 18<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Index Registers<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">IR0 to IR15<br \/>\nThese are special registers for storing PLC memory addresses for indirect addressing. (Index Registers can be set so that they are unique in each task or so that they are shared by all tasks.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Cyclic Task Flag Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">128 flags<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Memory Card<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">128 MB, 256 MB, or 512 MB<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Operating Modes<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">PROGRAM Mode: Programs are not executed. Preparations can be executed prior to program execution in this mode.<br \/>\nMONITOR Mode: Programs are executed, and some operations, such as online editing, and changes to present values in I\/O memory, are enabled in this mode.<br \/>\nRUN Mode: Programs are executed. This is the normal operating mode.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Execution Mode<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Normal Mode<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>Programming Languages<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Ladder Logic (LD),<br \/>\nSequential Function Charts (SFC),<br \/>\nStructured Text (ST), and<br \/>\nInstruction Lists (IL)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Function<br \/>\nBlocks<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Maximum number of definitions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2,048<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Maximum number of instances<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">2,048<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Tasks<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Type of Tasks<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Cyclic tasks<br \/>\nInterrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I\/O interrupt tasks, and external interrupt tasks)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Number of Tasks<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Cyclic tasks: 128<br \/>\nInterrupt tasks: 256<br \/>\n(Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of cyclic tasks is actually 384 max.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"8\"><strong>Symbols<br \/>\n(Variables)<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Type of Symbols<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Local symbols: Can be used only within a single task in the PLC.<br \/>\nGlobal symbols: Can be used in all tasks in the PLC.<br \/>\nNetwork symbols (tags): I\/O memory in the CPU Unit can be externally accessed using symbols, depending on parameter settings.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Data Type of Symbols<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">BOOL (bit)<br \/>\nUINT (one-word unsigned binary)<br \/>\nUDINT (two-word unsigned binary)<br \/>\nULINT (four-word unsigned binary)<br \/>\nINT (one-word signed binary)<br \/>\nDINT (two-word signed binary)<br \/>\nLINT (four-word signed binary)<br \/>\nUINT BCD (one-word unsigned BCD) *1<br \/>\nUDINT BCD (two-word unsigned BCD) *1<br \/>\nULINT BCD (four-word unsigned BCD) *1<br \/>\nREAL (two-word floating-point)<br \/>\nLREAL (four-word floating-point)<br \/>\nCHANNEL (word) *1<br \/>\nNUMBER (constant or number) *1<br \/>\nWORD (one-word hexadecimal)<br \/>\nDWORD (two-word hexadecimal)<br \/>\nLWORD (four-word hexadecimal)<br \/>\nSTRING (1 to 255 ASCII characters)<br \/>\nTIMER (timer) *2<br \/>\nCOUNTER (counter) *2<br \/>\nUser defined data types (data structures) *3<br \/>\n*1. Cannot be used in Function blocks<br \/>\n*2. Can be used only in Function blocks<br \/>\n*3. Supported only when CX-Programmer version 9.0 or later is used<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Maximum Size of Symbol<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">32k words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Array Symbols (Array Variables)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">One-dimensional arrays<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Number of Array Elements<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">32,000 elements max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Number of Registrable Network<br \/>\nSymbols (Tags)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">20,000 max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Length of Network Symbol (Tag) Name<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">255 bytes max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Encoding of Network Symbols (Tags)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">UTF-8<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Data<br \/>\nTracing<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"2\"><strong>Memory Capacity<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">8,000 words<\/td>\n<td class=\"left middle\">16,000 words<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">32,000 words<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">(The EM Area can be specified from the CX-Programmer to use up to 32K words multiplied by the number of banks supported by the CPU Unit model.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Number of Samplings<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Bits = 31, one-word data =16, two-word data = 8, four-word data = 4<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Sampling Cycle<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">1 to 2,550 ms (Unit: 1 ms)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Trigger Conditions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">ON\/OFF of specified bit<br \/>\nData comparison of specified word<br \/>\nData size: 1 word, 2 words, 4 words<br \/>\nComparison Method: Equals (=), Greater Than (&gt;), Greater Than or Equals (\u2265), Less Than (&lt;), Less Than or Equals (\u2264), Not Equal (\u2260)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Delay Value<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">&#8211; 32,768 to +32,767 ms<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"5\" rowspan=\"1\"><strong>File Memory<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Memory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.)<br \/>\nEM file memory (Part of the EM Area can be converted for use as file memory.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Source\/<br \/>\nComment<br \/>\nMemory<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Program sources, comments,<br \/>\nprogram indexes, symbol tables<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Capacity: 3.5 Mbytes<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"44\"><strong>Communi-<br \/>\ncations<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"2\"><strong>Logical Ports for<br \/>\nCommunications<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Logical Ports<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">8 ports (Used for SEND, RECV, CMND, PMCR, TXDU, and RXDU instructions.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Extended<br \/>\nLogical Ports<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">64 ports (Used for SEND2, RECV2, CMND2, and PMCR2 instructions.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"2\"><strong>CIP<br \/>\nCommunications<br \/>\nSpecification<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Class 3<br \/>\n(Connection Type)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Number of connections: 64<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>UCMM (Non-<br \/>\nconnection Type)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Maximum number of clients that can communicate at the same time: 32<br \/>\nMaximum number of servers that can communicate at the same time: 40<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Peripheral (USB) Port<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">USB 2.0-compliant B-type connector<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Baud Rate<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">12 Mbps max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Transmission Distance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">5 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Serial Port<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Interface: Conforms to EIA RS-232C.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><\/th>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Communications Method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Half-duplex<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Synchronization Method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Start-stop<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Baud Rate<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 (kbps)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Transmission Distance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">15 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>EtherNet\/IP Port<\/strong><\/th>\n<td class=\"center middle\" colspan=\"5\" rowspan=\"1\">&#8212;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"31\"><\/th>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"7\"><strong>Transmis-<br \/>\nsion<br \/>\nSpecifica-<br \/>\ntions<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Media Access<br \/>\nMethod<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">CSMA\/CD<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Modulation<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Baseband<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Transmission<br \/>\nPaths<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Star<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Baud Rate<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">100 Mbps (100Base-TX)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Transmission<br \/>\nMedia<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Shielded twisted-pair (STP) cable; Categories: 5, 5e<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Transmission<br \/>\nDistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">100 m (between hub and node)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of Cascade<br \/>\nConnections<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">No restrictions if switching hub is used.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"24\"><strong>Communi-<br \/>\ncations<br \/>\nSpecifica-<br \/>\ntions<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CIP<br \/>\nCommunications:<br \/>\nTag Data Links<\/strong><\/th>\n<td class=\"center middle\" colspan=\"5\" rowspan=\"1\">&#8212;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"14\"><\/th>\n<th class=\"heading left middle\"><strong>Number of<br \/>\nConnections<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">256<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Packet Interval<br \/>\n(Refresh period)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">0.5 to 10,000 ms (Unit: 0.5 ms)<br \/>\nCan be set for each connection. (Data will be refreshed at the set interval, regardless of the number of nodes.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum allowed<br \/>\ncommunications<br \/>\nbandwidth per Unit<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">6,000 to 12,000 pps *1 *2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of<br \/>\nRegisterable Tag<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">256<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Type of Tags<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">CIO, DM, EM, HR, WR, and Network symboles<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of Tags<br \/>\nper Connection<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">8 (Seven tags if PLC status is included in the segment.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum Link<br \/>\nData Size per<br \/>\nNode<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">184,832 words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum Data<br \/>\nSize per<br \/>\nConnection<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">252 or 722 words *3<br \/>\n(Data is synchronized within each connection.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of<br \/>\nRegistrable Tag<br \/>\nSet<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">256 (1 connection = 1 segment)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum Tag<br \/>\nSet Size<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">722 words (One word is used when PLC status is included in the segment.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum<br \/>\nNumber of Tags<br \/>\nRefreshable in a<br \/>\nSingle Cycle of<br \/>\nCPU Unit *4<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Output\/send (CPU Unit to EtherNet\/IP): 256<br \/>\nInput\/receive (EtherNet\/IP to CPU Unit): 256<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Data Size<br \/>\nRefreshable in a<br \/>\nSingle Cycle of<br \/>\nCPU Unit *4<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Output\/send (CPU to EtherNet\/IP): 6,432 words<br \/>\nInput\/receive (EtherNet\/IP to CPU): 6,432 words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Change of Tag<br \/>\nData Link<br \/>\nParameter<br \/>\nSettings during<br \/>\nOperation<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">OK *5<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Multi-cast Packet<br \/>\nFilter *6<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">OK<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CIP<br \/>\nCommunications:<br \/>\nExplicit Messages<\/strong><\/th>\n<td class=\"center middle\" colspan=\"5\" rowspan=\"1\">&#8212;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><\/th>\n<th class=\"heading left middle\"><strong>Class 3<br \/>\n(Connection Type)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Number of connections: 128<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>UCMM (Non-<br \/>\nconnection Type)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Maximum number of clients that can communicate at the same time: 32<br \/>\nMaximum number of servers that can communicate at the same time: 32<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>CIP Routing<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">OK (CIP routing is enabled for the following remote Units: CJ1W-EIP21, CJ2H-CPU6[]-EIP, CJ2M-CPU3[], and CS1W-EIP21.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>FINS<br \/>\nCommunications<\/strong><\/th>\n<td class=\"center middle\" colspan=\"5\" rowspan=\"1\">&#8212;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><\/th>\n<th class=\"heading left middle\"><strong>FINS\/UDP<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">OK<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>FINS\/TCP<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">16 connections max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP<br \/>\nConformance Test<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">Conforms to A5.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP<br \/>\nInterface<\/strong><\/th>\n<td class=\"left middle\" colspan=\"5\" rowspan=\"1\">10Base-T\/100Base-TX<br \/>\nAuto Negotiation\/Fixed Setting<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. &#8220;Packets per second&#8221; is the number of communications packets that can be processed per second.<br \/>\n*2. When using the EtherNet\/IP Unit with version 3.0 or later. When using the EtherNet\/IP Unit with version 2.1 or earlier,<br \/>\nthe maximum allowed communications bandwidth per Unit is 6,000 pps. When using the EtherNet\/IP Unit with version<br \/>\n3.0 or later, the Network Configurator with version 3.57 or higher is required.<br \/>\n*3. Large Forward Open (CIP optional specification) must be supported in order for 505 to 1,444 bytes to be used as the<br \/>\ndata size. Application is supported between CS\/CJ-series PLCs. When connecting to devices from other<br \/>\nmanufacturers,make sure that the devices support the Large Forward Open specification.<br \/>\n*4. If the maximum number is exceeded, refreshing will require more than one CPU Unit cycle.<br \/>\n*5. When changing parameters, however, the EtherNet\/IP port where the change is made will be restarted. In addition,<br \/>\na timeout will temporarily occur at the other node that was communicating with that port, and it will then recover<br \/>\nautomatically.<br \/>\n*6. The EtherNet\/IP port supports an IGMP client, so unnecessary multicast packets are filtered by using a switching<br \/>\nhub that supports IGMP snooping.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Function Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Functions<\/strong><\/td>\n<td class=\"heading center middle\"><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Cycle Time<br \/>\nManagement<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Minimum Cycle Time<\/strong><\/td>\n<td class=\"left middle\">A minimum cycle time can be set.<wbr \/><br \/>\n(<wbr \/>0.<wbr \/>2 to 32,<wbr \/>000 ms; Unit:<wbr \/>\u00a00.<wbr \/>1 ms)<wbr \/><br \/>\nThe minimum cycle time setting can be changed in MONITOR mode.<wbr \/>\u00a0(<wbr \/>Unit version 1.<wbr \/>1 or higher)<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Cycle Time Monitoring<\/strong><\/td>\n<td class=\"left middle\">The cycle time is monitored.<wbr \/>\u00a0(<wbr \/>0.<wbr \/>01 to 40,<wbr \/>000 ms; Unit:<wbr \/>0.<wbr \/>01 ms)<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Background Processing<\/strong><\/td>\n<td class=\"left middle\">Instructions with long execution times can be executed over multiple cycles to prevent fluctuations in the cycle time.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"12\"><strong>Unit (<wbr \/>I\/<wbr \/>O)<wbr \/><br \/>\nManagement<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Basic I\/<wbr \/>O<br \/>\nUnits,<wbr \/><br \/>\nSpecial<br \/>\nI\/<wbr \/>O Units,<wbr \/><br \/>\nand CPU<br \/>\nBus Units<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>I\/<wbr \/>O<br \/>\nRefreshing<\/strong><\/td>\n<td class=\"heading left middle\"><strong>Cyclic<br \/>\nRefreshing<\/strong><\/td>\n<td class=\"left middle\">Cyclic refreshing of Basic I\/<wbr \/>O Units,<wbr \/>\u00a0Special I\/<wbr \/>O Units,<wbr \/>and CPU Bus Units<\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>Immediate<br \/>\nRefreshing<\/strong><\/td>\n<td class=\"left middle\">I\/<wbr \/>O refreshing by immediate refreshing instructions<\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>Refreshing<br \/>\nby IORF<\/strong><\/td>\n<td class=\"left middle\">I\/<wbr \/>O refreshing by IORF instruction<\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Unit Recognition at Startup<\/strong><\/td>\n<td class=\"left middle\">The number of units recognized when the power is turned ON is displayed.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Basic I\/<wbr \/>O<br \/>\nUnits<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Input Response Time Setting<\/strong><\/td>\n<td class=\"left middle\">The input response times can be set for Basic I\/<wbr \/>O Units.<wbr \/>\u00a0The response time can be increased to reduce the effects of chattering and noise at input contacts.<wbr \/>The response time can be decreased to enable detecting shorter input pulses.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Load OFF Function<\/strong><\/td>\n<td class=\"left middle\">All of the outputs on Basic I\/<wbr \/>O Units can be turned OFF when an error occurs in RUN or MONITOR mode.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Basic I\/<wbr \/>O Unit Status<br \/>\nMonitoring<\/strong><\/td>\n<td class=\"left middle\">Alarm information can be read from Basic I\/<wbr \/>O Units and the number of Units recognized can be read.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Special I\/<wbr \/>O<br \/>\nUnits and<br \/>\nCPU Bus<br \/>\nUnits<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Unit Restart Bits to Restart<br \/>\nUnits<\/strong><\/td>\n<td class=\"left middle\">A Special I\/<wbr \/>O Unit or CPU Bus Unit can be restarted.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Synchronous Unit Operation<\/strong><\/td>\n<td class=\"left middle\">The start of processing for all the specified Units can be synchronized at a fixed interval.<wbr \/><br \/>\nMaximum number of Units:<wbr \/>\u00a010 Units<br \/>\n(<wbr \/>Only Units that support Synchronous Operation Mode can be used.<wbr \/>)<wbr \/><br \/>\nSynchronous operation cycle:<wbr \/>\u00a00.<wbr \/>5 to 10 ms (<wbr \/>default:<wbr \/>\u00a02 ms)<wbr \/><br \/>\nMaximum number of words for synchronous data refreshing:<wbr \/>\u00a096 words (<wbr \/>total of all Units)<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Configuration<br \/>\nManagement<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Automatic I\/<wbr \/>O Allocation at<br \/>\nStartup<\/strong><\/td>\n<td class=\"left middle\">I\/<wbr \/>O words can be automatically allocated to the Basic I\/<wbr \/>O Units that are connected in the PLC to start operation automatically without registering Units into I\/<wbr \/>O tables.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/<wbr \/>O Table Creation<\/strong><\/td>\n<td class=\"left middle\">The current unit configuration can be registered in I\/<wbr \/>O tables to prevent it from being changed,<wbr \/>\u00a0to reserve words,<wbr \/>\u00a0and to set words.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Rack\/<wbr \/>Slot First Word Settings<\/strong><\/td>\n<td class=\"left middle\">The first words allocated to a Units on the Racks can be set.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Memory<br \/>\nManagement<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Holding I\/<wbr \/>O Memory when Changing<br \/>\nOperating Modes<\/strong><\/td>\n<td class=\"left middle\">The status of I\/<wbr \/>O memory can be held when the operating mode is changed or power is turned ON.<wbr \/>\u00a0The forced-<wbr \/>set\/<wbr \/>reset status can be held when the operating mode is changed or power is turned ON.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>File Memory<\/strong><\/td>\n<td class=\"left middle\">Files (<wbr \/>such as program files,<wbr \/>\u00a0data files,<wbr \/>\u00a0and symbol table files)<wbr \/>\u00a0can be stored in Memory Card,<wbr \/>\u00a0EM File Memory,<wbr \/>\u00a0or Comment Memory.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Built-<wbr \/>in Flash Memory<\/strong><\/td>\n<td class=\"left middle\">The user program and Parameter Area can be backed up to an internal flash memory when they are transferred to the CPU Unit.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>EM File Function<\/strong><\/td>\n<td class=\"left middle\">Parts of the EM Area can be treated as file memory.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Storing Comments<\/strong><\/td>\n<td class=\"left middle\">I\/<wbr \/>O comments can be stored as symbol table files in a Memory Card,<wbr \/>\u00a0EM file memory,<wbr \/>\u00a0or comment memory.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>EM Configuration<\/strong><\/td>\n<td class=\"left middle\">EM Area can be set as trace memory or EM file memory.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Memory<br \/>\nCards<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Automatic File Transfer at Startup<\/strong><\/td>\n<td class=\"left middle\">A program file and parameter files can be read from a Memory Card when the power is turned ON.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Program Replacement during PLC Operation<\/strong><\/td>\n<td class=\"left middle\">The whole user program can be read from a Memory Card to CPU Unit during operation.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Function for Reading and Writing Data from<br \/>\na Memory Card<\/strong><\/td>\n<td class=\"left middle\">Data in I\/<wbr \/>O memory in the CPU Unit can be written to a Memory Card in CSV\/<wbr \/>TXT format.<wbr \/>\u00a0Data in CSV\/<wbr \/>TXT format in the Memory Card can be read to I\/<wbr \/>O memory in the CPU Unit.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Communications<\/strong><\/td>\n<td class=\"center middle\">&#8211;<wbr \/>&#8211;<wbr \/>&#8211;<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"11\"><\/td>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Peripheral (<wbr \/>USB)<wbr \/>\u00a0Port<\/strong><\/td>\n<td class=\"heading left middle\"><strong>Peripheral Bus<\/strong><\/td>\n<td class=\"left middle\">Bus for communications with various kinds of Support Software running on a personal computer.<wbr \/>\u00a0High-<wbr \/>speed communications are supported.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Serial Port<\/strong><\/td>\n<td class=\"center middle\">&#8211;<wbr \/>&#8211;<wbr \/>&#8211;<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><\/td>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Host Link (<wbr \/>SYSWAY)<wbr \/><br \/>\nCommunications<\/strong><\/td>\n<td class=\"left middle\">Host Link commands or FINS commands placed between Host Link headers and terminators can be sent from a host computer or PT to read\/<wbr \/>write I\/<wbr \/>O memory,<wbr \/>\u00a0read\/<wbr \/>control the operating mode,<wbr \/>\u00a0and perform other operations for PLC.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>No-<wbr \/>protocol Communications<\/strong><\/td>\n<td class=\"left middle\">I\/<wbr \/>O instructions for communications ports (<wbr \/>such as TXD\/<wbr \/>RXD instructions)<wbr \/>\u00a0can be used for data transfer with peripheral devices such as bar code readers and printers.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>NT Link Communications<\/strong><\/td>\n<td class=\"left middle\">I\/<wbr \/>O memory in the PLC can be allocated and directly linked to various PT functions,<wbr \/>\u00a0including status control areas,<wbr \/>\u00a0status notification areas,<wbr \/>\u00a0touch switches,<wbr \/>\u00a0lamps,<wbr \/>memory tables,<wbr \/>\u00a0and other objects.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Peripheral Bus<\/strong><\/td>\n<td class=\"left middle\">Bus for communications with various kinds of Support Software running on a personal computer.<wbr \/>\u00a0High-<wbr \/>speed communications are supported.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Serial Gateway<\/strong><\/td>\n<td class=\"left middle\">This gateway enables receiving and automatically converting FINS to the CompoWay\/<wbr \/>F.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>EtherNet\/<wbr \/>IP Port<\/strong><\/td>\n<td class=\"left middle\">100Base-<wbr \/>TX\/<wbr \/>10Base-<wbr \/>T<br \/>\nProtocols:<wbr \/>\u00a0TCP\/<wbr \/>IP,<wbr \/>\u00a0UDP,<wbr \/>\u00a0ARP,<wbr \/>\u00a0ICMP (<wbr \/>ping only)<wbr \/>,<wbr \/>BOOTP<br \/>\nApplications:<wbr \/>\u00a0FINS,<wbr \/>\u00a0CIP,<wbr \/>\u00a0SNTP,<wbr \/>\u00a0DNS (<wbr \/>Client)<wbr \/>,<wbr \/>\u00a0FTP (<wbr \/>Server)<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><\/td>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>CIP<br \/>\nCommu-<wbr \/><br \/>\nnications<br \/>\nService<\/strong><\/td>\n<td class=\"heading left middle\"><strong>Tag Data Links<\/strong><\/td>\n<td class=\"left middle\">Programless cyclic data exchanges with the devices on the EtherNet\/<wbr \/>IP network.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>Message<br \/>\nCommunications<\/strong><\/td>\n<td class=\"left middle\">Any CIP commands can be received from the devices on the EtherNet\/<wbr \/>IP network.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>FINS<br \/>\nCommun-<wbr \/><br \/>\nications<br \/>\nService<\/strong><\/td>\n<td class=\"heading left middle\"><strong>Message<br \/>\nCommunications<\/strong><\/td>\n<td class=\"left middle\">Any FINS commands can be transferred with the devices on the EtherNet\/<wbr \/>IP network.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><strong>Interrupt<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Scheduled Interrupts<\/strong><\/td>\n<td class=\"left middle\">Tasks can be executed at a specified interval (<wbr \/>minimum of 0.<wbr \/>2 ms or 0.<wbr \/>1 ms *<wbr \/>\u00a0,<wbr \/>\u00a0Unit:<wbr \/>\u00a00.<wbr \/>1 ms)<wbr \/>.<wbr \/><br \/>\n*<wbr \/>When High-<wbr \/>speed interrupt function is used.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Power OFF Interrupts<\/strong><\/td>\n<td class=\"left middle\">A task can be executed when CPU Unit&#8217;<wbr \/>s power turns OFF.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>I\/<wbr \/>O Interrupt Tasks<\/strong><\/td>\n<td class=\"left middle\">A task can be executed when an input signal is input to an Interrupt Input Unit.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>External Interrupt Tasks<\/strong><\/td>\n<td class=\"left middle\">A task can be executed when interrupts are requested from a Special I\/<wbr \/>O Unit or a CPU Bus Unit.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>High-<wbr \/>speed Interrupt Function<\/strong><\/td>\n<td class=\"left middle\">Improves performance for executing interrupt tasks with certain restrictions.<wbr \/><br \/>\n(<wbr \/>Unit version 1.<wbr \/>1 or later.<wbr \/>)<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"9\"><strong>Clock<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Clock Function<\/strong><\/td>\n<td class=\"left middle\">Cock data is stored in memory.<wbr \/><br \/>\nAccuracy (<wbr \/>Accuracy depends on the temperature.<wbr \/>)<wbr \/><br \/>\nAmbient temperature of 55 \u00b0 C:<wbr \/>\u00a0&#8211;<wbr \/>\u00a03.<wbr \/>5 to +<wbr \/>0.<wbr \/>5 min error per month<br \/>\nAmbient temperature of 25 \u00b0 C:<wbr \/>\u00a0&#8211;<wbr \/>\u00a01.<wbr \/>5 to +<wbr \/>1.<wbr \/>5 min error per month<br \/>\nAmbient temperature of 0 \u00b0 C:<wbr \/>\u00a0&#8211;<wbr \/>\u00a03 to +<wbr \/>1 min error per month<\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Operation Start Time Storage<\/strong><\/td>\n<td class=\"left middle\">The time when operating mode was last changed to RUN mode or MONITOR mode is stored.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Operation Stop Time Storage<\/strong><\/td>\n<td class=\"left middle\">The last time a fatal error occurred or the last time the operating mode was changed to PROGRAM mode is stored.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Startup Time Storage<\/strong><\/td>\n<td class=\"left middle\">The time when the power was turned ON is stored.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Power Interruption Time Storage<\/strong><\/td>\n<td class=\"left middle\">The time when the power is turned OFF is stored.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Total Power ON Time Calculation<\/strong><\/td>\n<td class=\"left middle\">The total time that the PLC has been ON is stored in increments of 10 hours.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Power ON Clock Data Storage<\/strong><\/td>\n<td class=\"left middle\">A history of the times when the power was turned ON is stored.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>User Program Overwritten Time Storage<\/strong><\/td>\n<td class=\"left middle\">The time that the user program was last overwritten is stored.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Parameter Date Storage<\/strong><\/td>\n<td class=\"left middle\">The time when the Parameter Area was overwritten is stored.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Power<br \/>\nSupply<br \/>\nManagement<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Memory Protection<\/strong><\/td>\n<td class=\"left middle\">Holding Area data,<wbr \/>\u00a0DM Area data,<wbr \/>\u00a0EM Area data,<wbr \/>Counter Completion Flags,<wbr \/>\u00a0and counter present values are held even when power is turned OFF.<wbr \/>\u00a0CIO Area,<wbr \/>Work Area,<wbr \/>\u00a0some Auxiliary Area data,<wbr \/>\u00a0and Timer Completion Flags,<wbr \/>\u00a0timer present values,<wbr \/>\u00a0index registers,<wbr \/>\u00a0and data registers can be protected by turning ON the IOM Hold Bit in the Auxiliary Area,<wbr \/>\u00a0and by also setting the IOM Hold Bit to &#8220;<wbr \/>Hold&#8221;<wbr \/>\u00a0in the PLC Setup.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Power OFF Detection Time Setting<\/strong><\/td>\n<td class=\"left middle\">The detection time for power interruptions can be set.<wbr \/><br \/>\nAC power supply:<wbr \/>\u00a010 to 25 ms (<wbr \/>variable)<wbr \/><br \/>\nDC power supply:<wbr \/>\u00a02 to 5 ms (<wbr \/>CJ1W-<wbr \/>PD022)<wbr \/>\u00a0or 2 to 20 ms (<wbr \/>CJ1W-<wbr \/>PD025)<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Power OFF Detection Delay Time<\/strong><\/td>\n<td class=\"left middle\">The detection of power interruptions can be delayed:<wbr \/>\u00a00 to 10 ms<br \/>\n(<wbr \/>Not supported by the CJ1W-<wbr \/>PD022.<wbr \/>)<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Number of Power Interruptions Counter<\/strong><\/td>\n<td class=\"left middle\">The number of times power has been interrupted is counted.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"4\" rowspan=\"1\"><strong>Function Blocks<\/strong><\/td>\n<td class=\"left middle\">Standard programming can be encapsulated as function blocks.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Languages in Function Block Definitions<\/strong><\/td>\n<td class=\"left middle\">Ladder programming or structured text<\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Debugging<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Online Editing<\/strong><\/td>\n<td class=\"left middle\">The program can be changed during operation (<wbr \/>in MONITOR or PROGRAM mode)<wbr \/>,<wbr \/>\u00a0except for block programming areas.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Force-<wbr \/>Set\/<wbr \/>Reset<\/strong><\/td>\n<td class=\"left middle\">Specified bits can be set or reset.<wbr \/><br \/>\nForce-<wbr \/>set\/<wbr \/>reset to the EM Area is enabled by specifying a start bank in parameter setting.<wbr \/>\u00a0(<wbr \/>unit version 1.<wbr \/>2 or higher)<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Differentiate Monitoring<\/strong><\/td>\n<td class=\"left middle\">ON\/<wbr \/>OFF changes in specified bits can be monitored.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Data Tracing<\/strong><\/td>\n<td class=\"left middle\">The specified I\/<wbr \/>O memory data can be stored in the trace memory in the CPU Unit.<wbr \/>\u00a0The triggers can be set.<wbr \/><br \/>\nThe trace data can be uploaded during data tracing using CX-<wbr \/>Programmer,<wbr \/>\u00a0which enables continuously logging the data by constantly uploading the trace data (<wbr \/>trace data uploading during tracing)<wbr \/>.<wbr \/><br \/>\nData tracing can be automatically started when operation is started (<wbr \/>i.<wbr \/>e.<wbr \/>,<wbr \/>\u00a0when the operating mode is changed from PROGRAM mode to MONITOR or RUN mode)<wbr \/>.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Storing Location of Error when an Error<br \/>\nOccurs<\/strong><\/td>\n<td class=\"left middle\">The location and task number where execution stopped for a program error is recorded.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Program Check<\/strong><\/td>\n<td class=\"left middle\">The programs can be checked for items such as no END instruction and FALS\/<wbr \/>FAL errors at startup.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"38\"><strong>Self-<wbr \/><br \/>\ndiagnosis<br \/>\nand<br \/>\nRestoration<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Error Log<\/strong><\/td>\n<td class=\"left middle\">A function is provided to store predefined error codes in CPU Unit,<wbr \/>\u00a0error information,<wbr \/>\u00a0and time at which the error occurred.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>CPU Error Detection<\/strong><\/td>\n<td class=\"left middle\">CPU Unit WDT errors are detected.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>User-<wbr \/>defined Failure Diagnosis<\/strong><\/td>\n<td class=\"left middle\">Errors can be generated for user-<wbr \/>specified conditions:<wbr \/>Non-<wbr \/>fatal errors (<wbr \/>FAL)<wbr \/>\u00a0and fatal errors (<wbr \/>FALS)<wbr \/>.<wbr \/><br \/>\nProgram section time diagnosis and program section logic diagnosis are supported (<wbr \/>FPD instruction)<wbr \/>.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Load OFF Function<\/strong><\/td>\n<td class=\"left middle\">This function turns OFF all outputs from Output Units when an error occurs.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>RUN Output<\/strong><\/td>\n<td class=\"left middle\">The RUN output from the CJ1W-<wbr \/>PA205R turns ON while CPU Unit is in RUN mode or MONITOR mode.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Basic I\/<wbr \/>O Load Short-<wbr \/>circuit Detection<\/strong><\/td>\n<td class=\"left middle\">This function provides alarm information from Basic I\/<wbr \/>O Units that have load short-<wbr \/>circuit protection.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Failure Point Detection<\/strong><\/td>\n<td class=\"left middle\">The time and logic of an instruction block can be analyzes using the FPD instruction.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>CPU Standby Detection<\/strong><\/td>\n<td class=\"left middle\">This function indicates when the CPU Unit is on standby because all Special I\/<wbr \/>O Units and CPU Bus Units have not been recognized at the startup in RUN or MONITOR mode.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"11\"><strong>Non-<wbr \/>fatal<br \/>\nError<br \/>\nDetection<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>System FAL Error Detection<br \/>\n(<wbr \/>User-<wbr \/>defined non-<wbr \/>fatal error)<wbr \/><\/strong><\/td>\n<td class=\"left middle\">This function generates a non-<wbr \/>fatal (<wbr \/>FAL)<wbr \/>\u00a0error when the user-<wbr \/>defined conditions are met in program.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Duplicate Refreshing Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when an immediate refreshing Instruction in an interrupt task is competing with I\/<wbr \/>O refreshing of a cyclic task.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Basic I\/<wbr \/>O Unit Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects the errors in Basic I\/<wbr \/>O Units.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Backup Memory Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function detects errors in the memory backup of the user programs and parameter area (<wbr \/>backup memory)<wbr \/>.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>PLC Setup Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects setting errors in the PLC Setup.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CPU Bus Unit Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when there is an error in data exchange between the CPU Unit and a CPU Bus Unit.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Special I\/<wbr \/>O Unit Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when there is an error in data exchange between the CPU Unit and a Special I\/<wbr \/>O Unit.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Tag Memory Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects errors in tag memory.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Battery Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when a battery is not connected to the CPU Unit or when the battery voltage drops.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CPU Bus Unit Setting Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when the model of a CPU Bus Unit in the registered I\/<wbr \/>O tables does not agree with the model that is actually mounted in the PLC.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Special I\/<wbr \/>O Unit Setting Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when the model of a Special I\/<wbr \/>O Unit in the registered I\/<wbr \/>O tables does not agree with the model of Unit that is actually mounted.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"18\"><strong>Fatal Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Memory Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects errors that occur in memory of the CPU Unit.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/<wbr \/>O Bus Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects when an error occurs in data transfers between the Units mounted in Rack slots and the CPU Unit and detects when the End Cover is not connected to the CPU Rack or an Expansion Rack.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Unit\/<wbr \/>Rack Number<br \/>\nDuplication Error<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when the same unit number is set for two or more Units,<wbr \/>\u00a0the same word is allocated to two or more Basic I\/<wbr \/>O Units,<wbr \/>\u00a0or the same rack number is set for two or more Racks.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Too Many I\/<wbr \/>O Points Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when the total number of I\/<wbr \/>O points set in the I\/<wbr \/>O tables or the number of Units per Rack exceeds the specified range.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/<wbr \/>O Setting Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when the number of Units in the registered I\/<wbr \/>O tables does not agree with the actual number of Units that is mounted,<wbr \/>\u00a0or an Interrupt Unit has been connected in the wrong position,<wbr \/>\u00a0i.<wbr \/>e.<wbr \/>,<wbr \/>\u00a0not in slot 0 to 3.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Program Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects errors in programs.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"8\"><\/td>\n<td class=\"heading left middle\"><strong>Instruction<br \/>\nProcessing<br \/>\nError Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when the given data value is invalid when executing an instruction,<wbr \/>\u00a0or execution of instruction between tasks was attempted.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>Indirect DM\/<wbr \/>EM<br \/>\nBCD Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when an indirect DM\/<wbr \/>EM address in BCD mode is not BCD.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>Illegal Area<br \/>\nAccess Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when an attempt is made to access an illegal area with an instruction operand.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>No END Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when there is no END instruction at the end of the program.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>Task Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when there are no tasks that can be executed in a cycle,<wbr \/>\u00a0there is no program for a task,<wbr \/>\u00a0or the execution condition for an interrupt task was met but there is no interrupt task with the specified number.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>Differentiation<br \/>\nOverflow Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when too many differentiated instructions are entered or deleted during online editing (<wbr \/>131,<wbr \/>072 times or more)<wbr \/>.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>Invalid<br \/>\nInstruction<br \/>\nError Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when an attempt is made to execute an instruction that is not defined in the system.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>User Program<br \/>\nArea Overflow<br \/>\nError Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when instruction data is stored after the last address in user program area.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Cycle Time Exceeded Error<br \/>\nDetection<\/strong><\/td>\n<td class=\"left middle\">This function monitors the cycle time (<wbr \/>10 to 40,<wbr \/>000 ms)<wbr \/>and stops the operation when the set value is exceeded.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>System FALS Error Detection<br \/>\n(<wbr \/>User-<wbr \/>defined Fatal Error)<wbr \/><\/strong><\/td>\n<td class=\"left middle\">This function generates a fatal (<wbr \/>FALS)<wbr \/>\u00a0error when the user-<wbr \/>defined conditions are met in program.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Version Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when a user program includes a function that is not supported by the current unit version.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Memory Card Transfer Error Detection<\/strong><\/td>\n<td class=\"left middle\">This function detects an error when the automatic file transfer from Memory Card fails at startup.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Memory Self-<wbr \/>restoration Function<\/strong><\/td>\n<td class=\"left middle\">This function performs a parity check on the user program area and self-<wbr \/>restoration data.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><strong>Maintenance<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Simple Backup Function<\/strong><\/td>\n<td class=\"left middle\">This function collectively backs up the data in CPU Unit (<wbr \/>user programs,<wbr \/>\u00a0parameters,<wbr \/>\u00a0and I\/<wbr \/>O memory)<wbr \/>\u00a0and internal backup data in the I\/<wbr \/>O Units.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Unsolicited Communications<\/strong><\/td>\n<td class=\"left middle\">A function that allows the PLC to use Network Communications Instruction to send required FINS commands to a computer connected via a Host Link<\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Remote Programming and Monitoring<\/strong><\/td>\n<td class=\"left middle\">Host Link communications can be used for remote programming and remote monitoring through a Controller Link,<wbr \/>\u00a0Ethernet,<wbr \/>\u00a0DeviceNet,<wbr \/>\u00a0or SYSMAC LINK Network.<wbr \/>\u00a0Communications across network layers can be performed.<wbr \/><br \/>\nController Link or Ethernet:<wbr \/>\u00a08 layers<br \/>\nDeviceNet or SYSMAC LINK:<wbr \/>\u00a03 layers<\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"2\" rowspan=\"2\"><strong>Automatic Online<br \/>\nConnection<br \/>\nvia Network<\/strong><\/td>\n<td class=\"heading left middle\"><strong>Direct Serial<br \/>\nConnection<\/strong><\/td>\n<td class=\"left middle\">This function enables automatically connecting to the PLC online when the CX-<wbr \/>Programmer is directly connected by a serial connection (<wbr \/>peripheral (<wbr \/>USB)<wbr \/>port or serial port)<wbr \/>.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\"><strong>Via Networks<\/strong><\/td>\n<td class=\"left middle\">This function enables connecting the CX-<wbr \/>Programmer online to a PLC that is connected via an EtherNet\/<wbr \/>IP network.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Security<\/strong><\/td>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Read Protection using Password<\/strong><\/td>\n<td class=\"left middle\">This function protects reading and displaying programs and tasks using passwords.<wbr \/><br \/>\nWrite protection:<wbr \/>\u00a0Set using the DIP switch.<wbr \/><br \/>\nRead protection:<wbr \/>\u00a0Set a password using the CX-<wbr \/>Programmer.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>FINS Write Protection<\/strong><\/td>\n<td class=\"left middle\">This function prohibits writing by using FINS commands sent over the network.<wbr \/><\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Unit Name Function<\/strong><\/td>\n<td class=\"left middle\">This function allows the users to give any names to the Units.<wbr \/>\u00a0Names are verified at online connection to prevent wrong connection<\/td>\n<\/tr>\n<tr>\n<td class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Hardware ID Using Lot Numbers<\/strong><\/td>\n<td class=\"left middle\">This function sets operation protection by identifying hardware using the user programs according to lot numbers stored in the Auxiliary Area.<wbr \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CJ2H CPU Unit<br \/>\nCJ2H-CPU6[]-EIP<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/cj2h-cpu-eip_dm_113-108474.jpg\" alt=\"CJ2H-CPU6[]-EIP Dimensions 2 CJ2H-CPU6[]-EIP_Dim\" \/><\/div>\n<\/div>\n<div><\/div>\n<div>\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj2h-cpu-eip_ds_e_10_3_csm1780.pdf?id=1993\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CJ2H-CPU6[]-EIP Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[662KB]<\/span><\/td>\n<td class=\"td_date\">Dec 03, 2018<\/td>\n<\/tr>\n<tr class=\"even\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj2h_cj2m_p059-e1_17_7_csm1004123.pdf?id=1993\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CJ2 Catalog<\/a><\/td>\n<td>P059-E1-11<br \/>\n<span class=\"file-size\">[14188KB]<\/span><\/td>\n<td class=\"td_date\">Dec 17, 2018<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cs_cj_cp_p097-e1-01.pdf?id=1993\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0New Functions Added to CS\/CJ\/CP Series Catalog<\/a><\/td>\n<td>P097-E1-01<br \/>\n<span class=\"file-size\">[1267KB]<\/span><\/td>\n<td class=\"td_date\">Sep 28, 2015<\/td>\n<\/tr>\n<tr class=\"even\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj1w_r150-e1_24_3_csm1003777.pdf?id=1993\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0EtherNet\/IP\u2122 Catalog<\/a><\/td>\n<td>R150-E1-16<br \/>\n<span class=\"file-size\">[2968KB]<\/span><\/td>\n<td class=\"td_date\">Sep 03, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">Flagship PLCs with Built-in Multifunctional Ethernet Port<\/h2>\n","protected":false},"featured_media":1562,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[91,63,72],"product_tag":[],"_links":{"self":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product\/1564"}],"collection":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/comments?post=1564"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media\/1562"}],"wp:attachment":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media?parent=1564"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1564"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1564"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}