{"id":1493,"date":"2019-01-03T00:55:38","date_gmt":"2019-01-03T00:55:38","guid":{"rendered":"http:\/\/store.al-tet.com\/?post_type=product&#038;p=1493"},"modified":"2019-01-03T00:55:38","modified_gmt":"2019-01-03T00:55:38","slug":"cj1w-clk","status":"publish","type":"product","link":"http:\/\/store.al-tet.com\/index.php\/product\/cj1w-clk\/","title":{"rendered":"CJ1W-CLK"},"content":{"rendered":"<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2022 Large-capacity data links are easily achieved without programming simply by setting data link tables.<\/p>\n<p>\u2022 Up to 20,000 *1 send\/receive words can be set per node for Units (up to 62,000 words for Boards).<\/p>\n<p>\u2022 Data links can be performed with up to 4,000 *2 words per node while ensuring data concurrency.<\/p>\n<p>\u2022 User-set data link tables can be changed while data links are operating. *3<\/p>\n<p>\u2022 Errors for the entire system can be monitored by using error diagnosis support software and a variety of status flags.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. Supported for unit version 1.2 or later.<br \/>\n*2. CJ1W-CLK23 and 3G8F7-CLK[]3 are supported.<br \/>\n*3. Supported for CJ1W-CLK23, 3G8F7-CLK[]3, and models ending with &#8220;-V1&#8221;.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-B02\">International Standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<ul class=\"listA01\">\n<li>The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.<\/li>\n<li>Contact your OMRON representative for further details and applicable conditions for these standards.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Controller Link Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nclas-<br \/>\nsifica-<br \/>\ntion<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>No. of<br \/>\nunit<br \/>\nnumbers<br \/>\nallocated<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Current<br \/>\nconsumption<br \/>\n(A)<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Stand-<br \/>\nards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Communi-<br \/>\ncations<br \/>\ncable<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Communi-<br \/>\ncations<br \/>\ntype<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Duplex<br \/>\nsupport<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Max. Units<br \/>\nmountable<br \/>\nper CPU<br \/>\nUnit<\/strong><\/td>\n<th class=\"heading center middle\"><strong>5 V<br \/>\nDC<\/strong><\/th>\n<td class=\"heading center middle\"><strong>24 V<br \/>\nDC<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>CJ1<br \/>\nCPU<br \/>\nBus<br \/>\nUnit<\/strong><\/th>\n<td class=\"heading left middle\"><strong>Controller<br \/>\nLink Unit<\/strong><\/p>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1452\/img\/1452_lu_1_1.gif\" \/><\/div>\n<\/td>\n<td class=\"left middle\">Wired shielded<br \/>\ntwisted-pair<br \/>\ncable *<\/td>\n<td class=\"left middle\">Data links<br \/>\nand message<br \/>\nservice<\/td>\n<td class=\"center middle\">No<\/td>\n<td class=\"center middle\">8<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"center middle\">0.35<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"left middle\"><strong>CJ1W-CLK23<\/strong><\/td>\n<td class=\"left middle\">UC1, N,<br \/>\nL, CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Note: This unit cannot be used with the Machine Automation Controller NJ-series.<br \/>\n* Use the following special cable for shielded, twisted-pair cable.<br \/>\n\u2022 ESVC0.5\u00d72C-13262 (Bando Electric Wire: Japanese Company)<br \/>\n\u2022 ESNC0.5\u00d72C-99-087B (JMACS Japan Co., Ltd.: Japanese Company)<br \/>\n\u2022 ESPC 1P\u00d70.5mm<sup>2<\/sup>\u00a0(Nagaoka Electric Wire Co.,Ltd.: Japanese Company)<br \/>\n\u2022 Li2Y-FCY2\u00d70.56qmm (Kromberg &amp; Schubert, Komtec Department: German Company)<br \/>\n\u2022 1\u00d72\u00d7AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)<br \/>\n\u2022 #9207 (Belden: US Company)<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Accessories<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>There is no accessory for the CJ series Controller Link Unit.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Controller Link Support Boards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product name<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Specifications<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Accessories<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Communications<br \/>\ncable<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Communications<br \/>\ntype<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Controller Link<br \/>\nSupport Board<br \/>\nfor PCI Bus<\/strong><\/p>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1452\/img\/1452_lu_2_1.gif\" \/><\/div>\n<\/th>\n<td class=\"left middle\">Wired shielded<br \/>\ntwisted-pair cable<\/td>\n<td class=\"left middle\">Data links and<br \/>\nmessage service<\/td>\n<td class=\"left middle\">CD-ROM x 1 *<br \/>\nINSTALLATION GUIDE (W467) x 1<br \/>\nCommunications connector x 1<\/td>\n<td class=\"left middle\"><strong>3G8F7-CLK23-E<\/strong><\/td>\n<td class=\"left middle\">CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>* The CD-ROM contains the following software.<br \/>\n\u2022 Controller Link (PCI) Driver<br \/>\n\u2022 FinsGateway Version 2003 (PCI-CLK Edition)<br \/>\n\u2022 FinsGateway Version 3 (PCI-CLK Edition)<br \/>\n\u2022 Setup Diagnostic Utility<br \/>\n\u2022 C Library<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Repeater Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Name<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Specifications<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Standards<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Controller Link<br \/>\nRepeater Unit<\/strong><\/p>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1452\/img\/1452_lu_3_1.gif\" \/><\/div>\n<\/th>\n<td class=\"left middle\">Wire-to-Wire Model<\/td>\n<td class=\"left middle\"><strong>CS1W-RPT01<\/strong><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">UC1, CE<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Wire-to-Optical (H-PCF) Model *1<\/td>\n<td class=\"left middle\"><strong>CS1W-RPT02<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Wire-to-Optical (GI) Model *2<\/td>\n<td class=\"left middle\"><strong>CS1W-RPT03<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks, 62-node configurations, and converting part of the network to optical cable.<br \/>\n*1. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF<br \/>\noptical fiber cable with connector.<br \/>\n*2. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Relay Terminal Block<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Name<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Specifications<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Standards<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Relay Terminal Block for<br \/>\nWired Controller Link Units<\/strong><\/p>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1452\/img\/1452_lu_4_1.gif\" \/><\/div>\n<\/th>\n<td class=\"left middle\">Used for Wired Controller Link Units (set of 5)<\/td>\n<td class=\"left middle\"><strong>CJ1W-TB101<\/strong><\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in advance on the Unit in a Wired Controller Link network. Relay Terminal Blocks cannot be used on Controller Link Support Boards.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">H-PCF Cables and Optical Connectors<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Name<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Application\/construction<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Model<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"10\">Optical Fiber Cables<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"10\">Controller<br \/>\nLink,<br \/>\nSYSMAC<br \/>\nLINK,<br \/>\nSYSBUS<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"10\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1452\/img\/1452_lu_5_1.gif\" \/><br \/>\n1. Optical fiber<br \/>\nsingle-core cord<br \/>\n2. Tension member<br \/>\n(plastic-sheathed wire)<br \/>\n3. Filler (plastic)<br \/>\n4. Filler surrounding<br \/>\nsignal wires<br \/>\n(plastic, yarn, or fiber)<br \/>\n5. Holding tape (plastic)<br \/>\n6. Heat-resistant PV<br \/>\nsheath<\/div>\n<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"10\">Two-core<br \/>\noptical<br \/>\ncable with<br \/>\ntension<br \/>\nmember<\/td>\n<td class=\"left middle\">Black 10 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCB101<\/strong><\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"12\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Black 50 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCB501<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Black 100 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCB102<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Black 500 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCB502<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Black 1000 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCB103<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Orange 10 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCO101<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Orange 50 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCO501<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Orange 100 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCO102<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Orange 500 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCO502<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Orange 1000 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCO103<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Optical<br \/>\nConnectors<br \/>\n(Crimp-cut)<\/td>\n<td class=\"center middle\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1452\/img\/1452_lu_5_2.gif\" \/><\/div>\n<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"2\">CS1W-RPT02<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Half lock<\/td>\n<td class=\"left middle\"><strong>S3200-COCF2571<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1452\/img\/1452_lu_5_3.gif\" \/><\/div>\n<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Full lock<\/td>\n<td class=\"left middle\"><strong>S3200-COCF2071<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">H-PCF Optical Fiber Cables with Connectors (Black Composite Cables with Two-Optical Lines and Two Power Supply Lines)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Application<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Appearance<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Standards<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Controller Link,<br \/>\nSYSMAC LINK<\/strong><\/th>\n<td class=\"center middle\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1452\/img\/1452_lu_6_1.gif\" \/><\/div>\n<\/td>\n<td class=\"left middle\"><strong>S3200-CN[][][]-20-20<\/strong><\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1452\/img\/1452_lu_6_2.gif\" \/><\/div>\n<\/td>\n<td class=\"left middle\"><strong>S3200-CN[][][]-20-25<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1452\/img\/1452_lu_6_3.gif\" \/><\/div>\n<\/td>\n<td class=\"left middle\"><strong>S3200-CN[][][]-25-25<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Cable Length<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The following cable lengths are available: 2 m, 5 m, 15 m, 20 m. For lengths of 21 m or more, contact your OMRON sales representative.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Model Numbers<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1452_lu_713-119111.gif\" alt=\"CJ1W-CLK Lineup 15 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Optical Connector Assembly Tool<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Name<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Applicable Unit<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Manufacturer<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Optical Fiber<br \/>\nAssembly Tool *<\/strong><\/th>\n<td class=\"left middle\">This tool is used on site for mounting crimp-cut connectors<br \/>\nand hard plastic-clad silica optical fiber for optical transmission<br \/>\nsystems of SYSMAC C-series SYSBUS, SYSMAC LINK, and<br \/>\nController Link.<\/td>\n<td class=\"left middle\"><strong>CAK-0057<\/strong><\/td>\n<td class=\"left middle\">Sumitomo Electric<br \/>\nIndustries, Ltd.<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>* There is a risk of quality problems when using cables assembled by typical users, so we recommend purchasing<br \/>\ncables with preattached connectors or having a qualified technician assemble the cables.<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<h4 class=\"heading-A02\">Communications Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Items<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">CJ1W-CLK23<br \/>\n3G8F7-CLK23-E<br \/>\nCJ1W-CLK21-V1 *1<br \/>\n3G8F7-CLK21-EV1 *1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Type<\/strong><\/th>\n<td class=\"left middle\">Wired (shielded twisted-pair cable)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Communications method<\/strong><\/th>\n<td class=\"left middle\">N:N token-bus method<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Code<\/strong><\/th>\n<td class=\"left middle\">Manchester code<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Modulation<\/strong><\/th>\n<td class=\"left middle\">Baseband code<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Synchronization<\/strong><\/th>\n<td class=\"left middle\">Flag synchronization (conforms to HDLC frames)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission path format<\/strong><\/th>\n<td class=\"left middle\">Multidrop method (bus type)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission speed<\/strong><\/th>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">The following are the maximum transmission distances depending on the transmission speed.<br \/>\n2 Mbits\/s: 500 m<br \/>\n1 Mbits\/s: 800 m<br \/>\n500 kbits\/s: 1 km<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum transmission<br \/>\ndistance<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum distance between<br \/>\nnodes<\/strong><\/th>\n<td class=\"left middle\">Not specified. (Maximum transmission distance must be satisfied for the entire system.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Medium<\/strong><\/th>\n<td class=\"left middle\">Specified shielded twist-pair cable<br \/>\nTwo signal wires, one shield<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Node connection method<\/strong><\/th>\n<td class=\"left middle\">PLC: Connection to terminal block<br \/>\nComputer: Connection using special (supplied) connector<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum number of nodes<\/strong><\/th>\n<td class=\"left middle\">32 or 62 nodes *2 *3<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Applicable Programming<br \/>\nDevices<\/strong><\/th>\n<td class=\"left middle\">CX-Integrator in CX-One, CX-Net in CX-Programmer *3, and Programming Console<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Communications functions<\/strong><\/th>\n<td class=\"left middle\">Data links and message service<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of data link words<\/strong><\/th>\n<td class=\"left middle\">Send words per node: 4,000 words max. (CJ1W-CLK[]3), 1,000 words max. (All other Units)<br \/>\nNumber of send\/receive words per node:<br \/>\n12,000 words max. (Pre-Ver. 1.2)<br \/>\n20,000 words max. (unit Ver. 1.2 or later)<br \/>\nTotal number of send words per network: 62,000 words max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Data link areas<\/strong><\/th>\n<td class=\"left middle\">PLC: Bit areas (CIO Area, Work Area, Link Area *4), Data Memory (DM), Extended DM Area (EM) Computer:<br \/>\nFinsGateway event memory<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Message length<\/strong><\/th>\n<td class=\"left middle\">2,012 bytes max. (including the header)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>RAS functions<\/strong><\/th>\n<td class=\"left middle\">Polling node backup function<br \/>\nSelf-diagnosis function (hardware checking at startup)<br \/>\nEchoback test and broadcast test (using the FINS command)<br \/>\nWatchdog timer<br \/>\nError log function<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Error control<\/strong><\/th>\n<td class=\"left middle\">Manchester code check<br \/>\nCRC check (CCITT X<sup>16<\/sup>\u00a0+X<sup>12<\/sup>\u00a0+X<sup>5<\/sup>\u00a0+1)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Discontinuation models in July 2012.<br \/>\n*2. With wired models, the maximum number of nodes is 32 if Repeater Units are not used. A Repeater Unit is required<br \/>\nwhen building a network with more than 32 nodes. If a Repeater Unit is used, be sure to use only the following<br \/>\nController Link Units or Boards and set the Wired Network 62 Node Enable Bit in the DM Parameter Area software<br \/>\nswitches at all nodes.<br \/>\nCS1W-CLK23\/CLK21-V1<br \/>\nCJ1W-CLK23\/CLK21-V1<br \/>\n3G8F7-CLK23-E\/CLK21-EV1<br \/>\n*3. CX-Net in CX-Programmer version 3.1 or earlier can be used only in a system with a maximum of 32 nodes (node<br \/>\naddress 1 to 32). If a system is to be used with a maximum of 62 nodes (node addresses 1 to 62), use CX-Net in<br \/>\nCX-Programmer version 3.2 or higher or the CX-Integrator.<br \/>\n*4. CJ-series PLCs do not have a Link Area, but LR000 to LR199 are automatically converted CIO 1000 to CIO 1199.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Individual Specifications<\/h4>\n<h4 class=\"heading-B02\">Controller Link Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Item<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">CJ1W-CLK23<br \/>\nCJ1W-CLK21-V1 *<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Applicable PLC<\/strong><\/th>\n<td class=\"left middle\">All CJ-series CPU Units<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of mountable Units<\/strong><\/th>\n<td class=\"left middle\">8 max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation site<\/strong><\/th>\n<td class=\"left middle\">Install onto a CPU Backplane or Expansion Backplane (classified as a CPU Bus Unit).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Storage location of network parameters and<br \/>\nmanually set data link tables<\/strong><\/th>\n<td class=\"left middle\">System Bus Unit Area (in the CPU Unit parameter area).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Storage location of routing tables<\/strong><\/th>\n<td class=\"left middle\">CPU Unit parameter area<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">110 g<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current consumption: 5 V in PLC<\/strong><\/th>\n<td class=\"left middle\">0.35 A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Discontinuation models in July 2012.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Controller Link Support Boards (for PCI Bus)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">3G8F7-CLK23-E<\/td>\n<td class=\"left middle\">3G8F7-CLK13-E<\/td>\n<td class=\"left middle\">3G8F7-CLK53-E<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Computer-compatible models<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">IBM PC\/AT or compatible<br \/>\nCPU: Intel Celeron 400 MHz or better<br \/>\nMain memory: 128 MB minimum<br \/>\nOne or more PCI bus slots (PCI bus revision 2.0 or later, power supply: 5 V)<br \/>\nFree hard disk space: 70 MB min.<br \/>\nCD-ROM drive: One required for installation<br \/>\nDisplay: VGA (640 x 480 (pixels) min.)<br \/>\n(Other conditions conform to the OS.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Compatible OS<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">FinsGateway Version2003 *1<br \/>\nWindows 10 (32bit)<br \/>\nWindows 8 (32bit)<br \/>\nWindows 7 (32bit) Professional<br \/>\nWindows 7 (32bit) Home Premium<br \/>\nWindows Vista Business<br \/>\nWindows Vista Home Premium<br \/>\nFinsGateway Version3 *2<br \/>\nWindows XP Professional<br \/>\nWindows XP Home Edition<br \/>\nWindows 2000 Professional<br \/>\nWindows NT4.0 (Service Pack 3 or higher)<br \/>\nWindows ME<br \/>\nWindows 98SE<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">104 g<\/td>\n<td class=\"left middle\">120 g (excluding mounting bracket)<\/td>\n<td class=\"left middle\">124 g (excluding mounting bracket)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Current<br \/>\nconsumption<\/strong><\/th>\n<th class=\"heading left middle\"><strong>5 V in PLC<\/strong><\/th>\n<td class=\"left middle\">0.35 A<\/td>\n<td class=\"left middle\">0.54 A<\/td>\n<td class=\"left middle\">0.60 A<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>External 24 V<\/strong><\/th>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"left middle\">0.35 A<\/td>\n<td class=\"left middle\">0.35 A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Install the software from CD Ver. 3.12 or higher if the operating system is Windows 10 or 8 (32bit).<br \/>\n*2. Install FinsGateway version 3 if the operating system is Windows NT 4.0 (Service pack 3 or higher), Windows ME, or<br \/>\nWindows 98SE. In that case, however, the new functions of Controller Link Support Boards for the PCI Bus cannot be<br \/>\nused (i.e., automatic data link creation with 1:N allocation, changing data link tables with active data links, 62-node<br \/>\nsetting for wired models, and maximum of 4000 send words).<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Repeater Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">CS1W-RPT01<\/td>\n<td class=\"left middle\">CS1W-RPT02<\/td>\n<td class=\"left middle\">CS1W-RPT03<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Supported Units\/Boards<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">All wired Controller Link Units and Boards<br \/>\nNote: If a maximum of 62 nodes is used, models that support 62 nodes must be used.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission line<\/strong><\/th>\n<td class=\"left middle\">Wire-to-wire<\/td>\n<td class=\"left middle\">Wire-to-optical (H-PCF)<\/td>\n<td class=\"left middle\">Wire-to-optical (GI)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission line format<\/strong><\/th>\n<td class=\"left middle\">Multi-drop<br \/>\nTree<\/td>\n<td class=\"left middle\">1:1 type<\/td>\n<td class=\"left middle\">1:1 type<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Repeater Units are not mounted to the PLC. They are mounted separately with screws or on a DIN Track.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">130 g<\/td>\n<td class=\"left middle\">130 g (excluding mounting bracket)<\/td>\n<td class=\"left middle\">130 g (excluding mounting bracket)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Allowable power supply<br \/>\nvoltage range<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">20.4 to 26.4 V DC (24 V DC -15 to 10%)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current consumption<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">24 V DC at 0.06 A<\/td>\n<td class=\"left middle\">24 V DC at 0.07 A<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Inrush current<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">2.5 A max. at 24 V DC (5 ms after startup)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Repeater Units are used to expand the Controller Link network for wired models. For Wired-to-optical Repeater Units, always use a set of two (1:1).<br \/>\nOptical Ring Controller Link Units and Boards cannot be connected to the optical cable section between Repeater Units.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CJ1W-CLK23\/CJ1W-CLK21-V1 *<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1452_dm_113-119112.gif\" alt=\"CJ1W-CLK Dimensions 1 \" \/><\/div>\n<div class=\"text\">\n<p>* Discontinuation models in July 2012.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"inner-contents-area\">\n<div class=\"primary-contents-area\">\n<div class=\"tabpanel-blockA01\">\n<div class=\"editable-block\">\n<div class=\"table-blockA01\">\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj1w-clk_ds_e_6_5_csm1611.pdf?id=1452\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CJ1W-CLK Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[945KB]<\/span><\/td>\n<td class=\"td_date\">Dec 17, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"local-navi-area\">\n<div class=\"local-navi-area\">\n<div class=\"local-naviA01\">\n<h2 class=\"heading-link\"><\/h2>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">New Controller Link Units, Now with 4,000 Send Words<\/h2>\n","protected":false},"featured_media":1477,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[92,63,72],"product_tag":[],"_links":{"self":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product\/1493"}],"collection":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/comments?post=1493"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media\/1477"}],"wp:attachment":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media?parent=1493"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1493"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}