{"id":1394,"date":"2019-01-02T03:00:28","date_gmt":"2019-01-02T03:00:28","guid":{"rendered":"http:\/\/store.al-tet.com\/?post_type=product&#038;p=1394"},"modified":"2019-01-02T03:00:28","modified_gmt":"2019-01-02T03:00:28","slug":"nx-ilm400-2","status":"publish","type":"product","link":"http:\/\/store.al-tet.com\/index.php\/product\/nx-ilm400-2\/","title":{"rendered":"NX-ILM400"},"content":{"rendered":"<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Downtime can be reduced.<\/strong><\/p>\n<p>Notifies you of faulty parts and such phenomena in the Sensor in real time.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>The frequency of sudden failure can be decreased.<\/strong><\/p>\n<p>Condition monitoring of sensors and equipment to prevent troubles.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>The efficiency of changeover can be improved.<\/strong><\/p>\n<p>The batch check for individual sensor IDs significantly decreases commissioning time.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">[To those in charge of maintenance \u201cCondition monitoring\u201d for predictive maintenance (1)] Reduction of Sudden Stops by Grasping the Flow Rate Simultaneously with the Temperature of Cooling Water and Hydraulic Oil Circulating in Equipment<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_113-263881.jpg\" alt=\"NX-ILM400 Features 4 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Existing problems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>While the presence or absence of cooling water is checked by means of the ON\/OFF-based pressure sensor, it is unable to detect any drop in the flow rate of the cooling water or any rise in the cooling water temperature. For that reason,<\/p>\n<p>\u2219 The transformer is not cooled, and gets overheated, potentially leading to sudden stops of the equipment and the entire line.<\/p>\n<p>\u2219 The tip may be deformed, causing defective products.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_213-263882.jpg\" alt=\"NX-ILM400 Features 5 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">With an IO-Link IoT Flow Sensor<\/h4>\n<h4 class=\"heading-B02\">The flow rate and simultaneously the temperature of the circulation system are measured, substantially reducing sudden error.<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Simultaneous monitoring of the flow rate and temperature changes, and informing of those changes, enable you to carry out predictive maintenance and reduce defective products.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_313-263883.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_3-13-263883-332x334.jpg\" alt=\"NX-ILM400 Features 7 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_313-263883.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">[To those in charge of maintenance \u201cCondition monitoring\u201d for predictive maintenance (2)] The Proximity Sensor Indicates an Excessive Proximity to the Sensing Object. Understand the Changes in Equipment Condition in Advance and Reduce Sudden Stops<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_113-263881.jpg\" alt=\"NX-ILM400 Features 8 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Existing problems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The detection position changes due to wear and vibration in the equipment\u2019s mechanical parts and as a result, false detection and collision with the sensor have a negative impact on the equipment&#8230;<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_413-263884.jpg\" alt=\"NX-ILM400 Features 9 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">With an IO-Link Proximity Sensor<\/h4>\n<h4 class=\"heading-B02\">You are notified of excessive remoteness or proximity, and the occurrence of sudden defects is greatly reduced<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Constantly monitoring the position of the sensing object and notifying of excessive remoteness or proximity can be used for predictive maintenance of the equipment.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_513-263885.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_5-13-263885-332x312.jpg\" alt=\"NX-ILM400 Features 11 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_513-263885.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">[To those in charge of maintenance \u201cCondition monitoring\u201d for predictive maintenance (3)] Understand Unstable Situations in the Incident Level of the Photoelectric Sensor in Advance and Reduce Sudden Stops<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_113-263881.jpg\" alt=\"NX-ILM400 Features 12 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Existing problems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2219 In a conveyance process operating for 24 hours, dust or dirt accumulated on the detection surface of the photoelectric sensor, leading to a decline in the light incident level that causes the sensor to make false detection and the equipment to stop&#8230;<\/p>\n<p>\u2219 Water drops stick to the sensing surface of the reflective sensor causing reflected light to enter&#8230;<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_613-263886.jpg\" alt=\"NX-ILM400 Features 13 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">With an IO-Link Photoelectric Sensor<\/h4>\n<h4 class=\"heading-B02\">A light incident level monitor prevents false detection<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>With a response time of 1 ms, Photoelectric Sensor\u2019s light incident level is output for monitoring. It is output when the light incident level exceeds the instability detection threshold, so you can check the site before false detection occurs and perform predictive maintenance.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_713-263887.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_7-13-263887-332x262.jpg\" alt=\"NX-ILM400 Features 15 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_713-263887.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">[To those in charge of maintenance \u201cAbnormality detection\u201d for the shortest recovery] Detects Wiring Cable Disconnections and Errors and Improves Equipment Operation Rate Through Quick Maintenance<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_813-263888.jpg\" alt=\"NX-ILM400 Features 16 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Existing problems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2219 An abnormality was displayed on the abnormality display screen, but upon going to look at the equipment, no external error was detected and the cause of the stop was not understood&#8230;<\/p>\n<p>\u2219 Those responsible for maintenance investigated the cause of the abnormality from the activity of the stopped equipment, but because the maintenance person relied on the skill he or she has to identify the abnormality and replace the failed sensor, stoppages from 2 hours to several days occur&#8230;<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_913-263889.jpg\" alt=\"NX-ILM400 Features 17 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">With an IO-Link Sensor<\/h4>\n<h4 class=\"heading-B02\">Abnormal area and phenomenon of sensors are reported in real time<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>When an abnormality occurs in a sensor, because you can see where the abnormality occurred and the factors estimated for it, you can go to where the abnormality occurred and recover the equipment in the shortest amount of time.<br \/>\nAlso with wire disconnection detection, not only output wires, but also power lines can be detected unconditionally.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1013-263890.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_10-13-263890-332x159.jpg\" alt=\"NX-ILM400 Features 19 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1013-263890.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Easy replacement of IO-Link sensors with Non-IO-Link sensors<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>You need a quick recovery but you have only Non-IO-Link sensors with no IO-Link sensors in stock. You probably think in such a case, the control program needs modifications, and requires additional time for the recovery.<br \/>\nWith IO-Link Master, since the IO-Link ON\/OFF data and the data for Non-IO-Link sensors are located in the same memory, replacement with Non-IO-Link sensors can be carried out without any modification of the control program, resulting in a reduction of the equipment downtime.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1113-263891.jpg\" alt=\"NX-ILM400 Features 20 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A01\">[To those in charge of production engineering \u201cIndividual identification\u201d for the reduction of man-hours] Improving System Commissioning and Changeover Efficiency by Checking Identifications in Batches<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1613-285168.jpg\" alt=\"NX-ILM400 Features 21 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Existing problems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2219 During system start-up or changeover, operators had to perform the I\/O check for each of the thousands of sensors installed on the line, and it took an enormous amount of time&#8230;<\/p>\n<p>\u2219 When a sensor is installed wrong or an error occurs, wasteful work occurred that would normally be unnecessary&#8230;<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1213-263892.jpg\" alt=\"NX-ILM400 Features 22 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">With an IO-Link Sensor<\/h4>\n<h4 class=\"heading-B02\">Without going to the site, you can check individual sensor identifications in batches, resulting in a sharp reduction of commissioning time<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>By checking the sensor identification (manufacturer\/sensor type\/model number), you can easily check mistakes such as misconnected or unconnected sensors and installation mistakes.<br \/>\nAlso, because it is possible to program multiple sensors at once using the command language used only for the controller, it is also possible to reduce commissioning time sharply.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1313-263893.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_13-13-263893-332x260.jpg\" alt=\"NX-ILM400 Features 24 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1313-263893.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">[Omron\u2019s IO-Link Compliant Equipment] Masters and Sensors Can Be Chosen to Match Your Situation<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>For the connection of IO-Link Sensors and IO-Link Masters, two types are available: a screw-less clamp terminal block and an M12 connector.<br \/>\nIn addition, NX-ILM400 IO-Link Master with screw-less clamp terminal block is connectable not only to EtherCAT, but also to EtherNet\/IP communication coupler units, and you can choose between them according to the system configuration.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1413-263894.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_14-13-263894-332x376.jpg\" alt=\"NX-ILM400 Features 25 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1413-263894.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div>\n<h4 class=\"heading-B02\">International Standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2022 The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, CE: EU Directives, RCM: Regulatory Compliance Mark, and KC: KC Registration.<\/p>\n<p>\u2022 Contact your OMRON representative for further details and applicable conditions for these standards.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">NX-series IO-Link Master Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nIO-Link ports<\/strong><\/th>\n<th class=\"heading center middle\"><strong>I\/O refreshing<br \/>\nmethod<\/strong><\/th>\n<th class=\"heading center middle\"><strong>I\/O connection<br \/>\nterminals<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-series IO-Link Master Unit<\/td>\n<td class=\"center middle\">4<\/td>\n<td class=\"left middle\">Free-Run refreshing<\/td>\n<td class=\"center middle\">Screwless clamping<br \/>\nterminal block<\/td>\n<td class=\"left middle\"><strong>NX-ILM400<\/strong><\/td>\n<td class=\"left middle\">UC1, CE, N,<br \/>\nRCM, KC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Peripheral Devices<\/h4>\n<h4 class=\"heading-A02\">Sensor I\/O Connectors<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Order a cable with a connector on one end to connect a sensor of connector type. Refer to the Ordering Information in the catalog of the sensor to connect or the Sensor I\/O Connectors\/Sensor Controllers on your local OMRON website for recommended products.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Optional Products<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Unit\/Terminal Block Coding Pins<\/strong><\/th>\n<td class=\"left middle\">Pins for 10 Units<br \/>\n(30 terminal block pins and 30 Unit pins)<\/td>\n<td class=\"center middle\"><strong>NX-AUX02<\/strong><\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>No. of<br \/>\nterminals<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Terminal number<br \/>\nindications<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Ground terminal<br \/>\nmark<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Terminal current<br \/>\ncapacity<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"center middle\">Terminal Block<\/td>\n<td class=\"center middle\">16<\/td>\n<td class=\"center middle\">A\/B<\/td>\n<td class=\"center middle\">Not provided<\/td>\n<td class=\"center middle\">10 A<\/td>\n<td class=\"center middle\"><strong>NX-TBA162<\/strong><\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Software<\/h4>\n<h4 class=\"heading-A02\">Automation Software Sysmac Studio<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Stand-<br \/>\nards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nlicenses<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Media<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Sysmac<br \/>\nStudio<br \/>\nStandard<br \/>\nEdition<br \/>\nVer.1.[][]<\/strong><\/th>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">The Sysmac Studio is the software that provides an<br \/>\nintegrated environment for setting, programming,<br \/>\ndebugging and maintenance of machine automation<br \/>\ncontrollers including the NJ\/NX-series CPU Units,<br \/>\nNY-series Industrial PC, EtherCAT Slave, and the HMI.<\/p>\n<p>Sysmac Studio runs on the following OS.<br \/>\nWindows 7 (32-bit\/64-bit version)\/Windows 8 (32-bit\/<br \/>\n64-bit version)\/Windows 8.1 (32-bit\/64-bit version)\/<br \/>\nWindows 10 (32-bit\/64-bit version)<\/p>\n<p>The Sysmac Studio Standard Edition DVD includes CX-<br \/>\nConfiguratorFDT to set up IO-Link Master Units and<br \/>\nIO-Link devices.<br \/>\nRefer to your OMRON website for details.<\/td>\n<td class=\"center middle\">&#8212;<br \/>\n(Media only)<\/td>\n<td class=\"center middle\">DVD<\/td>\n<td class=\"left middle\"><strong>SYSMAC-SE200D<\/strong><\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">1 license *<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"left middle\"><strong>SYSMAC-SE201L<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A01\">General Specification<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Enclosure<\/strong><\/th>\n<td class=\"left middle\">Must be built into a panel.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Grounding methods<\/strong><\/th>\n<td class=\"left middle\">Ground to 100 \u03a9 or less.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"11\"><strong>Operating<br \/>\nenvironment<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">0 to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\nhumidity<\/strong><\/th>\n<td class=\"left middle\">10% to 95% (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Atmosphere<\/strong><\/th>\n<td class=\"left middle\">Must be free from corrosive gases.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient storage<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">-25 to 70\u00b0C (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Altitude<\/strong><\/th>\n<td class=\"left middle\">2,000 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Pollution degree<\/strong><\/th>\n<td class=\"left middle\">Pollution degree 2 or less: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Noise immunity<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 61000-4-4, 2 kV (power line).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Overvoltage<br \/>\ncategory<\/strong><\/th>\n<td class=\"left middle\">Category: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EMC immunity level<\/strong><\/th>\n<td class=\"left middle\">Zone B<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Vibration resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-6.<br \/>\n5 to 8.4 Hz with amplitude of 3.5 mm,<br \/>\n8.4 to 150 Hz, acceleration of 9.8 m\/s<sup>2<\/sup><br \/>\n100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Shock resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-27. 147 m\/s<sup>2<\/sup>, 3 times each in X, Y, and Z directions<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Applicable standards *<\/strong><\/th>\n<td class=\"left middle\">UL 61010-2-201, ANSI\/ISA 12.12.01, EU: EN 61131-2, NK, LR, RCM, KC,<br \/>\nand IO-Link conformance<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Ask your OMRON representative for the most recent applicable standards for each model.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Unit Specification<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Unit name<\/strong><\/th>\n<td class=\"left middle\">IO-Link Master Unit<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">NX-ILM400<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of ports<\/strong><\/th>\n<td class=\"left middle\">4<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Communications<br \/>\nspecifications<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Communications protocol<\/strong><\/th>\n<td class=\"left middle\">IO-Link protocol<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Baud rate<\/strong><\/th>\n<td class=\"left middle\">COM1: 4.8kbps<br \/>\nCOM2: 38.4kbps<br \/>\nCOM3: 230.4kbps<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Topology<\/strong><\/th>\n<td class=\"left middle\">1:1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Compliant standards<\/strong><\/th>\n<td class=\"left middle\">\u2022 IO-Link Interface and System Specification Version1.1.2<br \/>\n\u2022 IO-Link Test Specification Version1.1.2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Power supply to<br \/>\ndevices* in<br \/>\nIO-Link Mode or<br \/>\nSIO (DI) Mode<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Rated voltage<\/strong><\/th>\n<td class=\"left middle\">24 VDC (20.4 to 28.8 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum load current<\/strong><\/th>\n<td class=\"left middle\">0.2 A\/port<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Short-circuit protection<\/strong><\/th>\n<td class=\"left middle\">Provided.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Digital inputs<br \/>\n(in SIO (DI)<br \/>\nMode)<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Internal I\/O common<\/strong><\/th>\n<td class=\"left middle\">PNP<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Rated voltage<\/strong><\/th>\n<td class=\"left middle\">24 VDC (20.4 to 28.8 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Input current<\/strong><\/th>\n<td class=\"left middle\">5 mA typical (24 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>ON voltage\/ON current<\/strong><\/th>\n<td class=\"left middle\">15 VDC min., 2 mA min.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>OFF voltage<\/strong><\/th>\n<td class=\"left middle\">5 VDC max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Input filter time<\/strong><\/th>\n<td class=\"left middle\">No filter, 0.25 ms, 0.5 ms, 1 ms (default), 2 ms, 4 ms, 8 ms, 16 ms,<br \/>\n32 ms, 64 ms,128 ms, 256 ms<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"7\"><strong>Digital outputs<br \/>\n(in SIO (DO)<br \/>\nMode)<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Internal I\/O common<\/strong><\/th>\n<td class=\"left middle\">PNP<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Output type<\/strong><\/th>\n<td class=\"left middle\">Push-pull<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Rated voltage<\/strong><\/th>\n<td class=\"left middle\">24 VDC (20.4 to 28.8 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum load current<\/strong><\/th>\n<td class=\"left middle\">0.1 A\/port<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Short-circuit protection<\/strong><\/th>\n<td class=\"left middle\">Provided.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Leakage current<\/strong><\/th>\n<td class=\"left middle\">0.1 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Residual voltage<\/strong><\/th>\n<td class=\"left middle\">1.5 V max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Digital inputs<br \/>\nfor pin 2<br \/>\n(in IO-Link<br \/>\nMode)<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Internal I\/O common<\/strong><\/th>\n<td class=\"left middle\">PNP<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Rated voltage<\/strong><\/th>\n<td class=\"left middle\">24 VDC (20.4 to 28.8 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Input current<\/strong><\/th>\n<td class=\"left middle\">2 mA typical (24 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>ON voltage\/ON current<\/strong><\/th>\n<td class=\"left middle\">15 VDC min., 2 mA min.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>OFF voltage<\/strong><\/th>\n<td class=\"left middle\">5 VDC max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Input filter time<\/strong><\/th>\n<td class=\"left middle\">No filter, 0.25 ms, 0.5 ms, 1 ms (default), 2 ms, 4 ms, 8 ms, 16 ms,<br \/>\n32 ms, 64 ms, 128ms, 256 ms<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Cable<br \/>\nspecifications<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Cable type<\/strong><\/th>\n<td class=\"left middle\">Unshielded<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Length<\/strong><\/th>\n<td class=\"left middle\">20 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Electrostatic capacity<br \/>\nbetween lines<\/strong><\/th>\n<td class=\"left middle\">3 nF max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Loop resistance<\/strong><\/th>\n<td class=\"left middle\">6 \u03a9 max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>External connection terminals<\/strong><\/th>\n<td class=\"left middle\">Screwless Clamping Terminal Block (16 terminals)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O refreshing method<\/strong><\/th>\n<td class=\"left middle\">Free-Run refreshing<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\">12 \u00d7 100 \u00d7 71 mm (W \u00d7 H \u00d7 D)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\">Photocoupler isolation<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Insulation resistance<\/strong><\/th>\n<td class=\"left middle\">20 M\u03a9 min. at 100 VDC (between isolated circuits)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Dielectric strength<\/strong><\/th>\n<td class=\"left middle\">510 VAC for 1 min, leakage current: 5 mA max. (between isolated<br \/>\ncircuits)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O power supply method<\/strong><\/th>\n<td class=\"left middle\">Supply from the NX bus<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit power consumption<\/strong><\/th>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit<br \/>\n1.05 W max.<br \/>\n\u2022 Connected to a Communications Coupler Unit<br \/>\n0.80 W max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Current consumption from I\/O power supply<\/strong><\/th>\n<td class=\"left middle\">50 mA<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">67 g<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Circuit configuration<\/strong><\/th>\n<td class=\"left middle\"><img title=\"3540_sp_2_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3540_sp_2_113-263896.gif\" alt=\"3540_sp_2_1\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Terminal connection diagram<\/strong><\/th>\n<td class=\"left middle\"><img title=\"3540_sp_2_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3540_sp_2_213-263897.gif\" alt=\"3540_sp_2_2\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Installation orientation and restrictions<\/strong><\/th>\n<td class=\"left middle\"><img title=\"3540_sp_2_3\" src=\"http:\/\/www.ia.omron.com\/Images\/3540_sp_2_313-263879.gif\" alt=\"3540_sp_2_3\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Protective functions<\/strong><\/th>\n<td class=\"left middle\">L+ terminal short-circuit protection<br \/>\nC\/Q terminal short-circuit protection<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Function Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Function<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Description<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Communications<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Cyclic<br \/>\ncommunications<\/strong><\/th>\n<td class=\"left middle\">I\/O data (process data) in the IO-Link devices is cyclically exchanged with the IO-Link Master Unit as the IO-Link communications master.<br \/>\nAt the same time, this data and the status of the IO-Link Master Unit is cyclically exchanged with the controller, with the IO-Link Master Unit operating as a slave of the controller.<br \/>\nCyclic communications can be used to check the amount of detection performance deterioration in devices, and to check changes in usage conditions, such as the amount of incident light for photoelectric sensors, stability detection margins, and excessive proximity for proximity sensors.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Message<br \/>\ncommunications<\/strong><\/th>\n<td class=\"left middle\">The controller can send messages (commands) to the IO-Link Master Unit and receive the response from the IO-Link Master Unit.<br \/>\nThe IO-Link Master Unit can also function as a gateway to send messages (commands and responses) between the controller and the IO-Link devices.<br \/>\nDuring operation, you can change and adjust device parameters, such as threshold settings, tuning execution, and ON-delay time changes, from a program.<br \/>\nOr, during operation, you can check the internal status, such as the operating times of devices.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Communications mode settings<\/strong><\/th>\n<td class=\"left middle\">You can select any of the following modes for each port:<br \/>\nIO-Link Mode, SIO (DI) Mode, SIO (DO) Mode, and Disable Port<br \/>\nThis allows you to combine IO-Link communications and digital I\/O in a single unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Digital inputs for pin 2<\/strong><\/th>\n<td class=\"left middle\">In IO-Link Mode, you can perform digital input with pin 2 while performing IO-Link communications.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Automatic baud rate setting for<br \/>\nIO-Link communications<\/strong><\/th>\n<td class=\"left middle\">The IO-Link Master Unit automatically matches the specific baud rates (COM1, COM2, or COM3) of the IO-Link devices to communicate with the IO-Link devices.<br \/>\nTherefore, it is not necessary to set the baud rate of the connected device for each port.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Connected device verification<\/strong><\/th>\n<td class=\"left middle\">This function is used to verify the configuration of IO-Link devices that are connected to the IO-Link Master Unit against the registered IO-Link device configuration settings when the power supply is turned ON.<br \/>\nThe user can enable or disable connected device verification.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>IO-Link communications error<br \/>\ndetection<\/strong><\/th>\n<td class=\"left middle\">This function detects I\/O cable breaks, disconnections from IO-Link device ports, error-level device events, device configuration verification errors, and IO-Link device malfunctions.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Detection of short-circuits in I\/O<br \/>\ncables<\/strong><\/th>\n<td class=\"left middle\">This function detects short-circuits in I\/O cables<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Notification of input data validity<\/strong><\/th>\n<td class=\"left middle\">The controller can use the Input Data Enabled Flags to determine whether the process input data for IO-Link communications is valid.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Load rejection for controller<br \/>\ncommunications error<\/strong><\/th>\n<td class=\"left middle\">This function turns OFF outputs from the IO-Link Master Unit when a communications error occurs in communications with the controller in IO-Link Mode or in an SIO mode.<br \/>\nThis prevents incorrect output operations when communications error occurs.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>IO-Link total communications lost<br \/>\nframes<\/strong><\/th>\n<td class=\"left middle\">The IO-Link total communications lost frames can be read from the CX-ConfiguratorFDT.<br \/>\nYou can use this function to determine communications status as affected by I\/O cable noise or other factors.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Digital input filter<\/strong><\/th>\n<td class=\"left middle\">This function is used to eliminate chattering and noise of the input signal for digital inputs in SIO(DI) Mode or for digital inputs for pin 2 in IO-Link Mode. It prevents data change and stabilizes the input signal even in situations where the input data changes due to chattering or noise and the bit status is unstable.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Digital input collection*<\/strong><\/th>\n<td class=\"left middle\">In IO-Link Mode, this function reflects the specified bit data in the input data from the IO-Link device on the digital input data of the IO-Link Master Unit. As a result, the bit data in the input data from the IO-Link device can be aggregated into the digital input data of the IO-Link Master Unit. One bit for each IO-Link port can be aggregated. This function cannot be used in SIO (DI) Mode and SIO (DO) Mode.<br \/>\nIf you use this function, digital inputs with pin 2 cannot be used.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Backup and restoration of<br \/>\nparameter settings in IO-Link<br \/>\ndevices<\/strong><\/th>\n<td class=\"left middle\">This function is used to back up parameter settings in IO-Link devices in the IO-Link Master Unit or restore them to IO-Link devices.<br \/>\nThis eliminates the need to set parameters again after replacing an IO-Link device.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Event log<\/strong><\/th>\n<td class=\"left middle\">This function records events, such as errors and status changes, that occur in the IO-Link Master Unit and the IO-Link devices.<br \/>\nThis enables partial troubleshooting for NJ\/NX-series Controllers and NY-series Industrial PCs.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* This function is supported with the unit version 1.1 or later.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Version Information<\/h4>\n<h4 class=\"heading-A03\">Connecting with CPU Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Refer to the user&#8217;s manual for the CPU Unit for the CPU Unit to which NX Units can be connected<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Corresponding versions *<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Studio<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CX-ConfiguratorFDT<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-ILM400<\/td>\n<td class=\"center middle\">Ver.1.1<\/td>\n<td class=\"center middle\">Ver1.13 or later<\/td>\n<td class=\"center middle\">Ver1.20 or higher<\/td>\n<td class=\"center middle\">Ver2.3 or higher<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver.1.0<\/td>\n<td class=\"center middle\">Ver.1.13 or later<\/td>\n<td class=\"center middle\">Ver.1.17 or higher<\/td>\n<td class=\"center middle\">Ver.2.3 or higher<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user\u2019s manuals for the specific Units for the relation between models and versions.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Connecting with Coupler Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"7\" rowspan=\"1\"><strong>Corresponding versions *<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>EtherCAT<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>EtherNet\/IP<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Communi-<br \/>\ncations<br \/>\nCoupler<br \/>\nUnit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NJ\/NX-<br \/>\nseries<br \/>\nCPU Units<br \/>\nor<br \/>\nNY-series<br \/>\nIndustrial<br \/>\nPCs<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CX-<br \/>\nConfigurator<br \/>\nFDT<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Communi-<br \/>\ncations<br \/>\nCoupler<br \/>\nUnit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CX-<br \/>\nConfigurator<br \/>\nFDT<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-ILM400<\/td>\n<td class=\"center middle\">Ver.1.1<\/td>\n<td class=\"center middle\">Ver.1.0<br \/>\nor later<\/td>\n<td class=\"center middle\">Ver.1.12<br \/>\nor later<\/td>\n<td class=\"center middle\">Ver.1.20<br \/>\nor higher<\/td>\n<td class=\"center middle\">Ver.2.2<br \/>\nor higher<\/td>\n<td class=\"center middle\">Ver.1.0<br \/>\nor later<\/td>\n<td class=\"center middle\">Ver.1.20<br \/>\nor higher<\/td>\n<td class=\"center middle\">Ver.2.2<br \/>\nor higher<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver.1.0<\/td>\n<td class=\"center middle\">Ver.1.0<br \/>\nor later<\/td>\n<td class=\"center middle\">Ver.1.12<br \/>\nor later<\/td>\n<td class=\"center middle\">Ver.1.16<br \/>\nor higher<\/td>\n<td class=\"center middle\">Ver.2.2<br \/>\nor higher<\/td>\n<td class=\"center middle\">Ver.1.0<br \/>\nor later<\/td>\n<td class=\"center middle\">Ver.1.16<br \/>\nor higher<\/td>\n<td class=\"center middle\">Ver.2.2<br \/>\nor higher<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user\u2019s manuals for the specific Units for the relation between models and versions.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>NX-ILM400<br \/>\n12 mm Width<\/strong><\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_dm_113-263880.gif\" alt=\"NX-ILM400 Dimensions 1 \" \/><\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/io-link_series_y229-e1_6_1_csm1053004.pdf?id=3540\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0IO-Link Series Catalog<\/a><\/td>\n<td>Y229-E1-02<br \/>\n<span class=\"file-size\">[28505KB]<\/span><\/td>\n<td class=\"td_date\">Jul 17, 2018<\/td>\n<\/tr>\n<tr class=\"even\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/nx_series_r183-e1_7_6_csm1040123.pdf?id=3540\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-series I\/O System Catalog<\/a><\/td>\n<td>R183-E1-09<br \/>\n<span class=\"file-size\">[6683KB]<\/span><\/td>\n<td class=\"td_date\">Nov 01, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">IO-Link makes sensor level information visible and solves the three major issues at manufacturing sites! The screwless clamping terminal block reduces wiring work.<\/h2>\n","protected":false},"featured_media":1395,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[98,63,72],"product_tag":[],"_links":{"self":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product\/1394"}],"collection":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/comments?post=1394"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media\/1395"}],"wp:attachment":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media?parent=1394"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1394"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1394"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}