{"id":1365,"date":"2019-01-02T01:47:59","date_gmt":"2019-01-02T01:47:59","guid":{"rendered":"http:\/\/store.al-tet.com\/?post_type=product&#038;p=1365"},"modified":"2019-01-02T01:51:14","modified_gmt":"2019-01-02T01:51:14","slug":"nx-csg-sl5-si-so","status":"publish","type":"product","link":"http:\/\/store.al-tet.com\/index.php\/product\/nx-csg-sl5-si-so\/","title":{"rendered":"NX-CSG \/ SL5 \/ SI \/ SO"},"content":{"rendered":"<h4 class=\"heading-A01\">Flexible safety system for large-scale production<\/h4>\n<h4 class=\"heading-A02\">EtherNet\/IP for safety across the world<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Production systems have to meet worldwide standards because of the globalization of production.<br \/>\nCIP Safety is a protocol for transmitting safety data via EtherNet\/IP that is adopted by factory automation and robot manufacturers all over the world. Using CIP Safety, you can build globally standardized networks and simplify the global procurement of production systems.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">One connection using CIP Safety<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Safety systems for industrial robots are becoming increasingly used; networks can be easily built with the NX-CSG Communication Control Unit and NX-SL5 Safety CPU Units which support CIP Safety.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_113-285415.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 3 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A03\">EtherNet\/IP brings flexibility<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Multiple network ports enable a safety network to be divided into several segments, making it easy to connect many network devices required for a large production line. This allows flexibility to add or remove devices from existing safety systems.<\/p>\n<p>Safety control between lines : Port 1<br \/>\nRobot control within process : Port 2A, 2B<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_213-285416.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 4 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A03\">Fast and fixed response cycle facilitates reconfiguration<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The NX-CSG320 Communication Control Unit and NX-SL5 Safety CPU Unit provide safety communications via CIP safety and at the same time provides local high-speed safety I\/O control. With a local I\/O response time as low as every 50 ms, the NX-SL5 Safety CPU Unit can be used for applications where a high level of responsiveness is required.<br \/>\n* Calculate the response speed of your system taking the performance of I\/O devices into consideration. Refer to the manual for details.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_313-285417.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 5 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A03\">Standardize the safety system network for a large robot system<\/h4>\n<h4 class=\"heading-B02\">System configuration<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>In this example, devices and machines communicate via EtherNet\/IP and CIP Safety in this system.<br \/>\nEach process includes robots, safety light curtains, emergency stop switches, and other safety components. The NX-CSG Communication Control Unit and NX-SL5 Safety CPU Unit execute safety control programs in each process. CIP Safety is used for safety interlocking between processes and for building a safety control network across the system.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_413-285418.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_4-13-285418-332x389.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 7 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_413-285418.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Interlocking between various machines<\/h4>\n<h4 class=\"heading-A02\">Simple configuration<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>CIP Safety allows safety devices and standard devices to be mixed on the same network, providing safety interlock control between machines. CIP Safety robots and remote I\/O terminals can be easily connected.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Modular processes bring flexibility to line layouts<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The NX-CSG320 Communication Control Unit and NX-SL5 Safety CPU Unit exchange interlock signals with other machines while implementing safety control within the machine. Programs for machine control and safety control can be created for each machine. This modularized design helps standardize design and improve design efficiency.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Modular machines with individual CPU units<\/h4>\n<h4 class=\"heading-B02\">System configuration<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Machine 1 and 3 are processing machines with the control program and safety control program for each machine.<br \/>\nMachine 2 is a material handling machine that transports products processed by Machine 1 and 3 to the next process. The NX-CSG320 Communication Control Unit and NX-SL5 Safety CPU Unit are used for all machines, and CIP Safety is used for safety interlocking between machines.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_513-285373.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_5-13-285373-332x177.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 12 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_513-285373.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Two different networks in a single system<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The NX-SL5 Safety CPU Unit connected with the NX102 Machine Automation Controller enables the use of both EtherCAT + FSoE (Safety over EtherCAT) and EtherNet\/IP + CIP Safety at the same time.<br \/>\nIn addition to interlock control within a machine via FSoE, safety interlock between machines can be implemented using CIP Safety.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Integrated safety into high-speed machine control<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The NX-SL5 Safety CPU Unit combination with the NX102 Machine Automation Controller , provides both safety control and machine control with fast cycle times.<br \/>\nBy mounting the NX-SL Safety CPU Unit and safety I\/O units to the NX102 and by connecting the servo drives via FSoE on EtherCAT, you can configure a simple motion and safety control system using high-speed networks.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Line safety control and fast machine control at the same time<\/h4>\n<h4 class=\"heading-B02\">System configuration<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The NX102 Machine Automation Controller and NX-SL5 Safety CPU Unit are used in Machine 1 and 2 to build a system with safety network and real-time control capabilities using EtherCAT. The machine status is reported to the host system and displayed on the HMI connected on the same network.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_613-285374.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_6-13-285374-332x183.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 16 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_613-285374.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Improve design productivity<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The Automation Software Sysmac Studio provides various functionalities to reduce time required for production system design and safety program verification.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">[Design] Reduce time required for production system design<\/h4>\n<h4 class=\"heading-B02\">Automatic Programming<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Create a truth table using input, output, and stop conditions of safety devices to automatically create a safety program for a simple machine.<\/p>\n<p>* Programs created by Automatic Programming will not guarantee functional safety.<br \/>\nRefer to the User&#8217;s Manual (Cat. No. Z395) for details.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_713-285375.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 19 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">User-defined Function Block (FB)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Programs can be easily converted into a user-defined function block (FB); help files can be attached to describe input and output conditions as well as the functionality of the program within the function block (FB). Different security levels can be set to protect the function block from viewing and unauthorized modifications.<\/p>\n<p>* User-defined FBs can be used as modular software components according to the hardware configuration. They help standardize programs and maintain the consistency of design quality.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_813-285376.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 20 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">[Verification] Implement safety management without experts and global standardization<\/h4>\n<h4 class=\"heading-B02\">Offline Simulation<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Programs can be simulated on your PC, Sysmac Studio allows verification of programs without connecting hardware.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_913-285377.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 22 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Online Functional Test<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Online Functional Test enables operation of safety functions to be checked when the NX-SL5 Safety CPU Unit is online with Sysmac Studio. The test results can be output as a report along with the safety signature; the safety signature is displayed on the seven-segment display of the NX-SL5 Safety CPU Unit, and can easily checked if the configuration matches the report after the program has been validated.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_1013-285378.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 23 \" \/><\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_1113-285379.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 24 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A01\">Maintenance without PC<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>No PC is required for maintenance, which reduces production system maintenance work and minimizes system downtime.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">[Operation] Minimize system downtime<\/h4>\n<h4 class=\"heading-B02\">Safety Data Logging<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>An SD card containing logging settings is used for Safety Data Logging.<br \/>\nWhen start trigger conditions are met, the specified device variables and exposed variables can be logged in a chronological order and output to the memory card.<br \/>\nThis function helps to quickly identify the cause of a sudden stoppage of the system and determine preventive measures.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_1213-285380.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 27 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">[Operation] Reduce maintenance work<\/h4>\n<h4 class=\"heading-B02\">Safety Unit Restore<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Programs and settings can be stored on an SD card inserted into the communication control unit. When the safety CPU unit is replaced, the stored programs and settings can be easily copied to a new unit using the SD card.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_1313-285381.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 29 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">ACR (Automatic Configuration Restart)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>When replacing a safety I\/O unit, just remove the old unit and mount a new unit. The setting data is automatically downloaded without using software.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_fe_1413-285382.jpg\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Features 30 \" \/><\/div>\n<\/div>\n<div><\/div>\n<div>\n<h4 class=\"heading-A03\">NX-series Communication Control Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Unit type<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Appearance<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Supported<br \/>\ncommunications<br \/>\nprotocol<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\ncommunications<br \/>\nconnectors<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Network<br \/>\nvariables<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Communication<br \/>\nControl Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong><img title=\"3719_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_lu_1_113-285383.gif\" alt=\"3719_lu_1_1\" \/><\/strong><\/th>\n<td class=\"center middle\">EtherNet\/IP\u00a0*1<\/td>\n<td class=\"center middle\">3<\/td>\n<td class=\"center middle\">2\u00a0*2<\/td>\n<td class=\"center middle\">Ver. 1.01<\/td>\n<td class=\"left middle\"><strong>NX-CSG320<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: One NX-END02 End Cover is provided with the NX-CSG320 Communication Control Unit.<br \/>\n*1. Routing of the CIP Safety protocol is supported.<br \/>\n*2. PORT1 is an independent port. PORT2A and PORT2B are the ports with a built-in Ethernet switch.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">NX-series Safety Control Units<\/h4>\n<h4 class=\"heading-B02\">Safety CPU Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit type<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Appearance<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Maximum number<br \/>\nof safety\u00a0I\/O<br \/>\npoints<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Program<br \/>\ncapacity<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nsafety\u00a0I\/O<br \/>\nconnections<\/strong><\/th>\n<th class=\"heading center middle\"><strong>I\/O<br \/>\nrefreshing<br \/>\nmethod<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Safety<br \/>\nCPU Unit<br \/>\n(NX-SL5[][][])<\/strong><\/th>\n<th class=\"heading center middle\"><strong><img title=\"3719_lu_2_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_lu_2_113-285384.gif\" alt=\"3719_lu_2_1\" \/><\/strong><\/th>\n<td class=\"center middle\">1024 points<\/td>\n<td class=\"center middle\">2048 KB<\/td>\n<td class=\"center middle\">128<\/td>\n<td class=\"center middle\">Free-Run<br \/>\nrefreshing<\/td>\n<td class=\"center middle\">Ver. 1.3<\/td>\n<td class=\"left middle\"><strong>NX-SL5500<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong><img title=\"3719_lu_2_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_lu_2_213-285385.gif\" alt=\"3719_lu_2_2\" \/><\/strong><\/th>\n<td class=\"center middle\">2032 points<\/td>\n<td class=\"center middle\">4096 KB<\/td>\n<td class=\"center middle\">254<\/td>\n<td class=\"center middle\">Free-Run<br \/>\nrefreshing<\/td>\n<td class=\"center middle\">Ver. 1.3<\/td>\n<td class=\"left middle\"><strong>NX-SL5700<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: Refer to your local OMRON website for details of the NX-SL3[][][] Safety CPU Unit.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Safety Input Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\ntype<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Appea-<br \/>\nrance<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"7\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Number<br \/>\nof<br \/>\nsafety<br \/>\ninput<br \/>\npoints<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Number<br \/>\nof test<br \/>\noutput<br \/>\npoints<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Internal<br \/>\nI\/O<br \/>\ncommon<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Rated<br \/>\ninput<br \/>\nvoltage<\/strong><\/th>\n<th class=\"heading center middle\"><strong>OMRON<br \/>\nspecial<br \/>\nsafety<br \/>\ninput<br \/>\ndevices<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Number<br \/>\nof safety<br \/>\nslave<br \/>\nconnec-<br \/>\ntions<\/strong><\/th>\n<th class=\"heading center middle\"><strong>I\/O<br \/>\nrefresh-<br \/>\ning<br \/>\nmethod<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Safety<br \/>\nInput<br \/>\nUnits<\/strong><\/th>\n<th class=\"heading center middle\"><strong><img title=\"3719_lu_3_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_lu_3_113-285386.gif\" alt=\"3719_lu_3_1\" \/><\/strong><\/th>\n<td class=\"center middle\">4 points<\/td>\n<td class=\"center middle\">2 points<\/td>\n<td class=\"center middle\">Sinking<br \/>\ninputs<br \/>\n(PNP)<\/td>\n<td class=\"center middle\">24 VDC<\/td>\n<td class=\"center middle\">Cannot be<br \/>\nconnected.<br \/>\n*<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"center middle\">Free-Run<br \/>\nrefreshing<\/td>\n<td class=\"center middle\">Ver. 1.1<\/td>\n<td class=\"left middle\"><strong>NX-SIH400<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong><img title=\"3719_lu_3_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_lu_3_213-285387.gif\" alt=\"3719_lu_3_2\" \/><\/strong><\/th>\n<td class=\"center middle\">8 points<\/td>\n<td class=\"center middle\">2 points<\/td>\n<td class=\"center middle\">Sinking<br \/>\ninputs<br \/>\n(PNP)<\/td>\n<td class=\"center middle\">24 VDC<\/td>\n<td class=\"center middle\">Cannot be<br \/>\nconnected.<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"center middle\">Free-Run<br \/>\nrefreshing<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<td class=\"left middle\"><strong>NX-SID800<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* The following OMRON special safety input devices can be connected directly without a special controller.<br \/>\nFor detail of connectable OMRON special safety input devices, refer to NX-series User&#8217;s Manual Safety Control Unit\/Communication Control Unit (Cat. No. Z395).<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Type<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model and corresponding PL and safety category<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">OMRON Single-beam Safety Sensors<\/td>\n<td class=\"left middle\">E3ZS<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">OMRON Non-contact Door Switches<\/td>\n<td class=\"left middle\">D40Z<br \/>\nD40A<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">OMRON Safety Mats<\/td>\n<td class=\"left middle\">UM, UMA<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">OMRON Safety Edges<\/td>\n<td class=\"left middle\">SGE (4-wire connection)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Safety Output Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\ntype<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Appea-<br \/>\nrance<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"6\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Number<br \/>\nof<br \/>\nsafety<br \/>\noutput<br \/>\npoints<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Internal<br \/>\nI\/O<br \/>\ncommon<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Maximum load<br \/>\ncurrent<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Rated<br \/>\nvoltage<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Number<br \/>\nof safety<br \/>\nslave<br \/>\nconnec-<br \/>\ntions<\/strong><\/th>\n<th class=\"heading center middle\"><strong>I\/O<br \/>\nrefresh-<br \/>\ning<br \/>\nmethod<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Safety<br \/>\nOutput<br \/>\nUnits<\/strong><\/th>\n<th class=\"heading center middle\"><strong><img title=\"3719_lu_4_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_lu_4_113-285388.gif\" alt=\"3719_lu_4_1\" \/><\/strong><\/th>\n<td class=\"center middle\">2 points<\/td>\n<td class=\"center middle\">Sourcing<br \/>\noutputs<br \/>\n(PNP)<\/td>\n<td class=\"left middle\">2.0 A\/point, 4.0 A\/<br \/>\nUnit at 40\u00b0C, and<br \/>\n2.5 A\/Unit at 55\u00b0C<br \/>\nThe maximum load<br \/>\ncurrent depends on<br \/>\nthe installation<br \/>\norientation and<br \/>\nambient<br \/>\ntemperature.<\/td>\n<td class=\"center middle\">24<br \/>\nVDC<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"center middle\">Free-Run<br \/>\nrefreshing<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<td class=\"left middle\"><strong>NX-SOH200<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong><img title=\"3719_lu_4_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_lu_4_213-285389.gif\" alt=\"3719_lu_4_2\" \/><\/strong><\/th>\n<td class=\"center middle\">4 points<\/td>\n<td class=\"center middle\">Sourcing<br \/>\noutputs<br \/>\n(PNP)<\/td>\n<td class=\"left middle\">0.5 A\/point and<br \/>\n2.0 A\/Unit<\/td>\n<td class=\"center middle\">24<br \/>\nVDC<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"center middle\">Free-Run<br \/>\nrefreshing<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<td class=\"left middle\"><strong>NX-SOD400<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Automation Software Sysmac Studio<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nlicenses<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Media<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Sysmac Studio<br \/>\nSafety Edition<br \/>\nVer. 1.[][] *1<\/strong><\/th>\n<td class=\"left middle\">Sysmac Studio Safety Edition is a license including<br \/>\nnecessary setting functions for the safety control<br \/>\nsystem.<br \/>\n* This product is a license only. You need the Sysmac<br \/>\nStudio Standard Edition DVD media to install it.<\/td>\n<td class=\"center middle\">1 license<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"left middle\"><strong>SYSMAC-FE001L<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Sysmac Studio<br \/>\nStandard<br \/>\nEdition<br \/>\nVer. 1.[][] *2<\/strong><\/th>\n<td class=\"left middle\">The Sysmac Studio is the software that provides an<br \/>\nintegrated environment for setting, programming,<br \/>\ndebugging and maintenance of machine automation<br \/>\ncontrollers including the NJ\/NX-series CPU Units,<br \/>\nNY-series Industrial PC, EtherCAT Slave, and the HMI.<\/p>\n<p>Sysmac Studio runs on the following OS.<br \/>\nWindows 7 (32-bit\/64-bit version)\/8 (32-bit\/64-bit<br \/>\nversion)\/8.1 (32-bit\/64-bit version)\/10 (32-bit\/64-bit<br \/>\nversion)<\/td>\n<td class=\"center middle\">&#8212;<br \/>\n(Media only)<\/td>\n<td class=\"center middle\">DVD<\/td>\n<td class=\"left middle\"><strong>SYSMAC-SE200D<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: For details of the Automation Software Sysmac Studio, refer to your local OMRON website.<br \/>\n*1. The Safety Edition can be used with the Communication Control Unit and EtherNet\/IP Coupler Unit.<br \/>\n*2. The Sysmac Studio Standard Edition License (SYSMAC-SE2[][]L) includes functions that the Safety Edition (SYSMAC-FE001L) provides.<br \/>\nThe Communication Control Unit can be used with the Sysmac Studio version 1.24 or higher.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Optional Products<\/h4>\n<div class=\"component-blockA01 set-width\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Memory Card<\/strong><\/th>\n<td class=\"center middle\">SD memory card, 2 GB<\/td>\n<td class=\"left middle\"><strong>HMC-SD291<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">SD memory card, 4 GB<\/td>\n<td class=\"left middle\"><strong>HMC-SD491<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Product Name<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">Unit\/Terminal Block Coding Pins<\/td>\n<td class=\"left middle\">For 10 Units (Terminal Block: 30 pins, Unit: 30 pins)<\/td>\n<td class=\"left middle\"><strong>NX-AUX02<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>No. of<br \/>\nterminals<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Terminal number<br \/>\nindications<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Ground terminal<br \/>\nmark<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Terminal current<br \/>\ncapacity<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Terminal<br \/>\nBlock<\/td>\n<td class=\"center middle\">8<\/td>\n<td class=\"center middle\">A\/B<\/td>\n<td class=\"center middle\">Provided<\/td>\n<td class=\"center middle\">10 A<\/td>\n<td class=\"left middle\"><strong>NX-TBC082<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">8<\/td>\n<td class=\"center middle\">A\/B<\/td>\n<td class=\"center middle\">None<\/td>\n<td class=\"center middle\">10 A<\/td>\n<td class=\"left middle\"><strong>NX-TBA082<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">16<\/td>\n<td class=\"center middle\">A\/B<\/td>\n<td class=\"center middle\">None<\/td>\n<td class=\"center middle\">10 A<\/td>\n<td class=\"left middle\"><strong>NX-TBA162<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Accessories<\/h4>\n<h4 class=\"heading-A03\">Communication Control Unit Accessories<\/h4>\n<h4 class=\"heading-B02\">End Cover (NX-END02): 1<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>One End Cover is provided with the Communication Control Unit.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Specifications<\/h4>\n<h4 class=\"heading-A02\">Regulations and Standards<\/h4>\n<h4 class=\"heading-A03\">NX-series Safety Control Units<\/h4>\n<h4 class=\"heading-B02\">Safety CPU Units NX-SL5500\/SL5700<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>T\u00dcV Rheinland *1<\/strong><\/th>\n<td class=\"left middle\">\u2022 EN ISO 13849-1<br \/>\n\u2022 EN ISO 13849-2<br \/>\n\u2022 IEC 61508 parts 1-7<br \/>\n\u2022 IEC\/EN 62061<br \/>\n\u2022 IEC\/EN 61131-2<br \/>\n\u2022 IEC 61326-3-1<br \/>\n\u2022 IEC 61131-6 *2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>UL<\/strong><\/th>\n<td class=\"left middle\">\u2022 NRAG (UL 61010-1, UL 61010-2-201 and UL 121201)<br \/>\n\u2022 NRAG7 (CSA C22.2 No. 61010-1, CSA C22.2 No. 61010-2-201 and CSA C22.2 No. 213)<br \/>\n\u2022 FSPC (IEC 61508 and ISO 13849) *2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Safety Input\/Output Units NX-SI\/SO<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Certification body<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>T\u00dcV Rheinland *1<\/strong><\/th>\n<td class=\"left middle\">\u2022 EN ISO 13849-1<br \/>\n\u2022 EN ISO 13849-2<br \/>\n\u2022 IEC 61508 parts 1-7<br \/>\n\u2022 IEC\/EN 62061<br \/>\n\u2022 IEC\/EN 61131-2<br \/>\n\u2022 IEC 61326-3-1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>UL<\/strong><\/th>\n<td class=\"left middle\">\u2022 NRAG (UL 508 and ANSI\/ISA 12.12.01)<br \/>\n\u2022 NRAG7 (CSA C22.2 No. 142 and CSA C22.2 No. 213)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. The FSoE protocol was certified for applications in which OMRON FSoE devices are connected to each other.<br \/>\nFor compatibility with FSoE devices other than OMRON FSoE devices, the customer must validate FSoE<br \/>\ncommunications.<br \/>\n*2. Only NX-SL5500\/5700 have obtained IEC 61131-6 and FSPC certifications.<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>The NX-series Safety Control Units allow you to build a safety control system that meets the following standards.<br \/>\n\u2022 Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, IEC\/EN 62061, (Functional Safety of\u00a0Electrical\/Electronic\/<br \/>\nProgrammable Electronic Safety-related Systems)<br \/>\n\u2022 Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1<\/p>\n<p>The NX-series Safety Control Units are also registered for RCM, EAC, and KC compliance.<\/p><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">NX-series Communication Control Unit NX-CSG320<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Certification body<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>UL<\/strong><\/th>\n<td class=\"left middle\">\u2022 NRAG (UL 61010-1, UL 61010-2-201 and UL 121201)<br \/>\n\u2022 NRAG7 (CSA C22.2 No. 61010-1, CSA C22.2 No. 61010-2-201 and CSA C22.2 No.213)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The NX-series Communication Control Units are also registered for RCM, EAC, and KC compliance.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">General Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Enclosure<\/strong><\/th>\n<td class=\"left middle\">Mounted in a panel (open)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Grounding method<\/strong><\/th>\n<td class=\"left middle\">Ground to 100\u00a0\u03a9\u00a0or less<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"14\"><strong>Operating<br \/>\nenvironment<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Ambient operating temperature<\/strong><\/th>\n<td class=\"left middle\">0 to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient operating humidity<\/strong><\/th>\n<td class=\"left middle\">10% to 95% (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Atmosphere<\/strong><\/th>\n<td class=\"left middle\">Must be free from corrosive gases.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient storage temperature<\/strong><\/th>\n<td class=\"left middle\">-25 to 70\u00b0C (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Altitude<\/strong><\/th>\n<td class=\"left middle\">2,000 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Polsption degree<\/strong><\/th>\n<td class=\"left middle\">2 or less: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Noise immunity<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 61131-2.<br \/>\n2 kV on power supply line<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation class<\/strong><\/th>\n<td class=\"left middle\">Class III (SELV)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Overvoltage category<\/strong><\/th>\n<td class=\"left middle\">Category II: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EMC immunity level<\/strong><\/th>\n<td class=\"left middle\">Zone B<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Vibration resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-6.<br \/>\n5 to 8.4 Hz with 3.5-mm amplitude<br \/>\n8.4 to 150 Hz, acceleration of 9.8 m\/s<sup>2<\/sup><br \/>\n100 minutes each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Shock resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-27.<br \/>\n147 m\/s<sup>2<\/sup>, 3 times each in X, Y, and Z directions<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation resistance\u00a0*<\/strong><\/th>\n<td class=\"left middle\">20 M\u03a9\u00a0between isolated circuits (at 100 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dielectric strength\u00a0*<\/strong><\/th>\n<td class=\"left middle\">510 VAC for 1 min between isolated circuits, leakage current: 5 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Installation method<\/strong><\/th>\n<td class=\"left middle\">DIN Track (IEC 60715 TH35-7.5\/TH35-15)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* The specification is for the Communication Control Unit, Safety Input Unit, and Safety Output Unit, not for the Safety CPU Unit.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Specifications of Individual Units<\/h4>\n<h4 class=\"heading-A02\">Communication Control Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Unit name<\/strong><\/th>\n<td class=\"left middle\">Communication Control Unit<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">NX-CSG320<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Indicators<\/strong><\/th>\n<td class=\"left middle\">[RUN] indicator, [ERROR] indicator, [BUSY] indicator, [SD PWR] indicator,<br \/>\n[SD BUSY] indicator, [NS] indicator \u00d7 2, [L\/A] indicator, [L\/A 2A] indicator,<br \/>\n[L\/A 2B] indicator, [TS] indicator, [UNIT PWR] indicator, [I\/O PWR] indicator<br \/>\n<img title=\"3719_sp_4_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_4_113-285390.gif\" alt=\"3719_sp_4_1\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Hardware switch settings<\/strong><\/th>\n<td class=\"left middle\">[IP ADDRESS 1] Switch (x16, x1),<br \/>\n[IP ADDRESS 2] Switch (x16, x1), DIP Switch<br \/>\n<img title=\"3719_sp_4_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_4_213-285391.gif\" alt=\"3719_sp_4_2\" \/><\/p>\n<p>* Factory default<br \/>\n\u2022 IP ADDRESS1: 192.168.1.1 [IP ADDRESS 1] Switch = \u201c00\u201d<br \/>\n\u2022 IP ADDRESS2: 192.168.250.1 [IP ADDRESS 2] Switch = \u201c00\u201d<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Dimensions\u00a0*1<\/strong><\/th>\n<td class=\"left middle\">72 \u00d7 100 \u00d7 90 mm (W \u00d7 H \u00d7 D)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight\u00a0*2<\/strong><\/th>\n<td class=\"left middle\">390 g<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of NX Units that you can connect<\/strong><\/th>\n<td class=\"left middle\">32 units or less<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of communications that<br \/>\ncan be set between NX Units<\/strong><\/th>\n<td class=\"left middle\">254 ports max. *3<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><strong>Unit<br \/>\npower<br \/>\nsupply<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Power supply voltage<\/strong><\/th>\n<td class=\"left middle\">24 VDC (20.4 to 28.8 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Unit power consumption *4<\/strong><\/th>\n<td class=\"left middle\">5.95 W<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Inrush current *5<\/strong><\/th>\n<td class=\"left middle\">For cold start at room temperature:<br \/>\n10 A max.\/0.1 ms max.<br \/>\nand<br \/>\n2.5 A max.\/150 ms max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current capacity of<br \/>\npower supply terminal *6<\/strong><\/th>\n<td class=\"left middle\">4 A<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\">No isolation: Between the Unit power supply terminal and internal circuit<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Power<br \/>\nsupply<br \/>\nto the<br \/>\nNX Unit<br \/>\npower<br \/>\nsupply<\/strong><\/th>\n<th class=\"heading left middle\"><strong>NX Unit power<br \/>\nsupply capacity<\/strong><\/th>\n<td class=\"left middle\">10 W max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power<br \/>\nsupply efficiency<\/strong><\/th>\n<td class=\"left middle\">80%<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\">No isolation: Between the Unit power supply terminal and NX Unit power supply<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>I\/O power<br \/>\nsupply to<br \/>\nNX Units<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Power supply voltage<\/strong><\/th>\n<td class=\"left middle\">5 to 24 VDC (4.5 to 28.8 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum I\/O power<br \/>\nsupply current<\/strong><\/th>\n<td class=\"left middle\">4 A<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Current consumption from I\/O power supply<\/strong><\/th>\n<td class=\"left middle\">10 mA max. (24 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>External connection terminals<\/strong><\/th>\n<td class=\"left middle\">Screwless clamping terminal block (8 terminals)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Terminal connection diagram<\/strong><\/th>\n<td class=\"left middle\">UV\/UG: Unit power supply terminals<br \/>\nIOV\/IOG: I\/O power supply terminals<br \/>\n<img title=\"3719_sp_4_3\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_4_313-285392.gif\" alt=\"3719_sp_4_3\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Accessories<\/strong><\/th>\n<td class=\"left middle\">End cover (NX-END02): 1 pc.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Installation orientation and restrictions<\/strong><\/th>\n<td class=\"left middle\">Only upright installation orientation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. Includes the End Cover, and does not include projecting parts.<br \/>\n*2. Includes the End Cover. The weight of the End Cover is 82 g.<br \/>\n*3. Includes the SD Memory Card. The NX Unit power consumption to NX Units is not included.<br \/>\n*4. This is the inrush current value when the power supply turns ON after it has been OFF.<br \/>\nThe inrush current may vary depending on the operating condition and other conditions. Therefore, select fuses, breakers, and external power supply devices that have enough margin in characteristic and capacity, considering the condition under which the devices are used.<br \/>\nEspecially when you turn the power ON\/OFF through a switch inserted to the external DC power supply, cycling power ON-OFF-ON within one second will cause the inrush current of approx. 30 A\/0.3 mA to occur since the inrush current limiter circuit fails to limit the current.<br \/>\n*5. The amount of current that can be passed constantly through the terminal. Do no exceed this current value when you use a through-wiring for the Unit power supply.<br \/>\n*6. The actual configurable number can be calculated as follows: 254 &#8211; &lt;Number of CIP Safety connections configured&gt; &#8211; &lt;Number of FSoE connections configured&gt;<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Built-in EtherNet\/IP Port Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The following table shows the specifications of the built-in EtherNet\/IP port of the Communication Control Unit.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"2\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>NX-CSG-[][][]<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Communications protocol<\/strong><\/th>\n<td class=\"left middle\">TCP\/IP or UDP\/IP<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Supported services<\/strong><\/th>\n<td class=\"left middle\">Sysmac Studio connection, tag data links, CIP message<br \/>\ncommunications, FTP server, automatic clock adjustment (NTP<br \/>\nclient), SNMP (agent), DNS (client), BOOTP (client), TCP\/ UDP<br \/>\nmessage service<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of logical ports<\/strong><\/th>\n<td class=\"left middle\">2 (With IP routing function)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Physical layer<\/strong><\/th>\n<td class=\"left middle\">100Base-TX or 10Base-T (100Base-TX is recommended.)\u00a0*1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"7\"><strong>Transmission<br \/>\nspecifications<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Media access method<\/strong><\/th>\n<td class=\"left middle\">CSMA\/CD<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Modulation<\/strong><\/th>\n<td class=\"left middle\">Baseband<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission paths<\/strong><\/th>\n<td class=\"left middle\">Star form<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Baud rate<\/strong><\/th>\n<td class=\"left middle\">100 Mbps (100BASE-TX)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission media<\/strong><\/th>\n<td class=\"left middle\">Shielded twisted-pair (STP) cable, Category 5, 5e or higher<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission distance<\/strong><\/th>\n<td class=\"left middle\">100 m max. (distance between hub and node)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of cascade<br \/>\nconnections<\/strong><\/th>\n<td class=\"left middle\">The built-in switching ports support up to 50 nodes.<br \/>\nThere is no limitation when an external Ethernet switch is used.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>CIP Safety<br \/>\nrouting<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Maximum number of routable<br \/>\nCIP Safety connections<\/strong><\/th>\n<td class=\"left middle\">254 total<br \/>\nFor multi-cast connections, 128 total<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum routable Safety<br \/>\ndata length per connection<\/strong><\/th>\n<td class=\"left middle\">32 bytes<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"14\"><strong>CIP service:<br \/>\nTag data links<br \/>\n(cyclic<br \/>\ncommunica-<br \/>\ntions)<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Number of connections<\/strong><\/th>\n<td class=\"left middle\">32\/Logical ports<br \/>\n(total of 64 with two logical ports)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Packet interval<br \/>\n(refresh cycle)<\/strong><\/th>\n<td class=\"left middle\">1 to 10,000 ms in 1-ms increments<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Packet intervals can be set independently for each connection.<br \/>\n(Data is refreshed over the network at preset intervals and does not<br \/>\ndepend on the number of nodes.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Allowed communications<br \/>\nbandwidth per Unit<\/strong><\/th>\n<td class=\"left middle\">12,000 pps\u00a0*2<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Note: The heartbeat and CIP Safety routing are incspded.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of registrable tags<\/strong><\/th>\n<td class=\"left middle\">1024\/Logical ports<br \/>\n(total of 2048 with two logical ports)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Tag types<\/strong><\/th>\n<td class=\"left middle\">Network variables<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of tags per<br \/>\nconnection (=1 tag set)<\/strong><\/th>\n<td class=\"left middle\">32 (31 tags if Controller status is incspded in the tag set.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum link data size per<br \/>\nnode<\/strong><\/th>\n<td class=\"left middle\">46,208 bytes\/Logical ports<br \/>\n92,416 bytes total<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum data size per<br \/>\nconnection<\/strong><\/th>\n<td class=\"left middle\">1,444 bytes\u00a0*3<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Number of registrable tag<br \/>\nsets<\/strong><\/th>\n<td class=\"left middle\">Data concurrency is maintained within each connection.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">32 per port<br \/>\n(1 connection = 1 tag set)<br \/>\n(total of 40 with two logical ports) *4<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum size of 1 tag set<\/strong><\/th>\n<td class=\"left middle\">1,444 bytes<br \/>\n(Two bytes are used if Controller status is incspded in the tag set.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Multi-cast packet filter\u00a0*5<\/strong><\/th>\n<td class=\"left middle\">Supported.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>CIP message<br \/>\nservice:<br \/>\nExplicit<br \/>\nmessages\u00a0*6<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Class 3 (number of<br \/>\nconnections)<\/strong><\/th>\n<td class=\"left middle\">Connections: 16\/Logical ports<br \/>\n(total of 32 with two logical ports)<br \/>\n(server only)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>UCMM (unconnected)<\/strong><\/th>\n<td class=\"left middle\">Maximum number of clients that can communicate at one time: 16<br \/>\nper port (total of 32 with two logical ports)<br \/>\nMaximum number of servers that can communicate at one time: 16<br \/>\nper port (total of 32 with two logical ports)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>TCP\/UDP<br \/>\nmessage<br \/>\nservice<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Maximum number of clients<br \/>\nthat can communicate at<br \/>\none time<\/strong><\/th>\n<td class=\"left middle\">16 per port (total of 32 with two logical ports)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum message size<\/strong><\/th>\n<td class=\"left middle\">Request: 492 bytes<br \/>\nResponse: 496 bytes<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>SNMP<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Agent<\/strong><\/th>\n<td class=\"left middle\">SNMPv1, SNMPv2c<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>MIB<\/strong><\/th>\n<td class=\"left middle\">MIB-II<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP conformance test<\/strong><\/th>\n<td class=\"left middle\">Conforms to CT14<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Ethernet interface<\/strong><\/th>\n<td class=\"left middle\">10BASE-T or 100BASE-TX<br \/>\nAuto negotiation or fixed settings<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. If tag data links are being used, use 100Base-TX.<br \/>\n*2. Here, pps means \u201cpackets per second\u201d and indicates the number of packets that can be processed in one second.<br \/>\n*3. To use a data size of 505 bytes or higher, the system must support a large forward open (an optional CIP specification).<br \/>\nThe CS, CJ, NJ, and NX-series Units support a large forward open, but before connecting to nodes of other companies, confirm that those devices also support it.<br \/>\n*4. If more than 40 tag sets are registered in total, the Tag Data Link, Too Many Tag Sets Registered (840E0000 hex) event will occur.<br \/>\n*5. Because the built-in EtherNet\/IP port is equipped with an IGMP client (version 2), unnecessary multicast packets can be filtered out by an Ethernet switch that supports IGMP Snooping.<br \/>\n*6. The built-in EtherNet\/IP port uses the TCP\/UDP port numbers shown in the following table.<br \/>\nDo not set the same port number for more than one TCP\/UDP service.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Service<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Type<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Port number<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Remarks<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">Tag data links<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">2222<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"8\">Fixed vaspes<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Used by system<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">2223, 2224<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">TCP<\/td>\n<td class=\"left middle\">9610<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">CIP messages<\/td>\n<td class=\"left middle\">TCP<\/td>\n<td class=\"left middle\">44818<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">FTP client (Data transfer port)<\/td>\n<td class=\"left middle\">TCP<\/td>\n<td class=\"left middle\">20<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">DNS client<\/td>\n<td class=\"left middle\">TCP\/UDP<\/td>\n<td class=\"left middle\">53<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">BOOTP client<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">68<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">HTTP server<\/td>\n<td class=\"left middle\">TCP<\/td>\n<td class=\"left middle\">80<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Used by system, other<\/td>\n<td class=\"left middle\">TCP\/UDP<\/td>\n<td class=\"left middle\">9600<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">You can change the port number in the Unit<br \/>\nSettings on the Sysmac Studio.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">FTP client (Control port)<\/td>\n<td class=\"left middle\">TCP<\/td>\n<td class=\"left middle\">21<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">TCP\/UDP message service<\/td>\n<td class=\"left middle\">TCP\/UDP<\/td>\n<td class=\"left middle\">64000<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NTP client<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">123<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">SNMP agent<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">161<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">SNMP trap<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">162<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Safety Control Units<\/h4>\n<h4 class=\"heading-A03\">Safety CPU Units NX-SL5500\/SL5700<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>Unit name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Safety CPU Unit<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">NX-SL5500<\/td>\n<td class=\"left middle\">NX-SL5700<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum number<br \/>\nof safety I\/O points<\/strong><\/th>\n<td class=\"left middle\">1024 points<\/td>\n<td class=\"left middle\">2032 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Program capacity<\/strong><\/th>\n<td class=\"left middle\">2048 KB<\/td>\n<td class=\"left middle\">4096 KB<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of safety<br \/>\nmaster connections\u00a0*1<\/strong><\/th>\n<td class=\"left middle\">128<\/td>\n<td class=\"left middle\">254<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of CIP Safety<br \/>\noriginator connections<\/strong><\/th>\n<td class=\"left middle\">128<\/td>\n<td class=\"left middle\">254<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of CIP Safety<br \/>\ntarget connections<\/strong><\/th>\n<td class=\"left middle\">4<\/td>\n<td class=\"left middle\">4<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of originators that<br \/>\ncan be connected with<br \/>\na multi-cast connection<\/strong><\/th>\n<td class=\"left middle\">8<\/td>\n<td class=\"left middle\">8<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of FSoE master<br \/>\nconnections<\/strong><\/th>\n<td class=\"left middle\">128<\/td>\n<td class=\"left middle\">254<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O refreshing method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Free-Run refreshing<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>External connection terminals<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">None<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Indicators<\/strong><\/th>\n<td class=\"left middle\">[TS] indicator, [NS] indicator, [FS] indicator,<br \/>\n[P ERR] indicator, [RUN] indicator,<br \/>\n[VALID] indicator, [DEBUG] indicator,<br \/>\nseven-segment indicator<br \/>\n<img title=\"3719_sp_6_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_6_113-285393.gif\" alt=\"3719_sp_6_1\" \/><\/td>\n<td class=\"left middle\">[TS] indicator, [NS] indicator, [FS] indicator,<br \/>\n[P ERR] indicator, [RUN] indicator,<br \/>\n[VALID] indicator, [DEBUG] indicator,<br \/>\nseven-segment indicator<br \/>\n<img title=\"3719_sp_6_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_6_213-285394.gif\" alt=\"3719_sp_6_2\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Hardware switch settings<\/strong><\/th>\n<td class=\"left middle\">[SERVICE] switch,<br \/>\n[SETTING] switch<br \/>\n<img title=\"3719_sp_6_3\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_6_313-285395.gif\" alt=\"3719_sp_6_3\" \/><\/td>\n<td class=\"left middle\">[SERVICE] switch,<br \/>\n[SETTING] switch<br \/>\n<img title=\"3719_sp_6_4\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_6_413-285396.gif\" alt=\"3719_sp_6_4\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">30 \u00d7 100 \u00d7 71 mm (W \u00d7 H \u00d7 D)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O power supply method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Not supplied.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current capacity<br \/>\nof I\/O power supply<br \/>\nterminals<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">No I\/O power supply terminals<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power consumption<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">3.35 W max. *2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current consumption<br \/>\nfrom I\/O power supply<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">No consumption<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">130 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation orientation<br \/>\nand restrictions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Installation orientation: Upright installation<br \/>\nRestriction *3: None.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. This is the maximum number of Safety I\/O connections that can be set to this Unit. The value is the total number of CIP Safety originator connections, CIP Safety target connections, and FSoE master connections.<br \/>\n*2. The cable length for the Units (Communication Control Unit and Power Supply Unit for NX Units) that supply power to the corresponding Unit must be up to 20 m.<br \/>\n*3. Only NX102 CPU Units and Communication Control Units can be connected. NX1P2 CPU Units or Communications Coupler Units cannot be connected.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Safety Input Units NX-SIH400\/SID800<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>Unit name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Safety Input Unit<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">NX-SIH400<\/td>\n<td class=\"left middle\">NX-SID800<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of safety input<br \/>\npoints<\/strong><\/th>\n<td class=\"left middle\">4 points<\/td>\n<td class=\"left middle\">8 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of test output<br \/>\npoints<\/strong><\/th>\n<td class=\"left middle\">2 points<\/td>\n<td class=\"left middle\">2 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Internal I\/O common<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">PNP (sinking inputs)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Rated input voltage<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">24 VDC (20.4 to 28.8 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>OMRON special safety<br \/>\ninput\u00a0devices<\/strong><\/th>\n<td class=\"left middle\">Can be connected.<\/td>\n<td class=\"left middle\">Cannot be connected.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of safety slave<br \/>\nconnections<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O refreshing method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Free-Run refreshing<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>External connection<br \/>\nterminals<\/strong><\/th>\n<td class=\"left middle\">Screwless clamping terminal block<br \/>\n(8 terminals)<\/td>\n<td class=\"left middle\">Screwless clamping terminal block<br \/>\n(16 terminals)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Indicators<\/strong><\/th>\n<td class=\"left middle\">[TS] indicator, [FS] indicator, [IN] indicator,<br \/>\n[IN ERR] indicator<br \/>\n<img title=\"3719_sp_7_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_7_113-285397.gif\" alt=\"3719_sp_7_1\" \/><\/td>\n<td class=\"left middle\">[TS] indicator, [FS] indicator, [IN] indicator,<br \/>\n[IN ERR] indicator<br \/>\n<img title=\"3719_sp_7_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_7_213-285398.gif\" alt=\"3719_sp_7_2\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Safety input current<\/strong><\/th>\n<td class=\"left middle\">4.5 mA TYP.<\/td>\n<td class=\"left middle\">3.0 mA TYP.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Safety input ON voltage<\/strong><\/th>\n<td class=\"left middle\">11 VDC min.<\/td>\n<td class=\"left middle\">15 VDC min.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Safety input OFF<br \/>\nvoltage\/OFF current<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">5 VDC max., 1 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Test output type<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Sourcing outputs (PNP)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Test output load current<\/strong><\/th>\n<td class=\"left middle\">25 mA max.<\/td>\n<td class=\"left middle\">50 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Test output residual<br \/>\nvoltage<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">1.2 V max. (Between IOV and all output terminals)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Test output leakage<br \/>\ncurrent<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">0.1 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">12 \u00d7 100 \u00d7 71 mm (W \u00d7 H \u00d7 D)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Photocoupler isolation<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation resistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">20 M\u03a9\u00a0min. between isolated circuits (at 100 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dielectric strength<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">510 VAC for 1 min between isolated circuits, leakage current: 5 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O power supply method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Power supplied from the NX bus<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current capacity of I\/O<br \/>\npower supply terminals<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">No applicable terminals.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power<br \/>\nconsumption<\/strong><\/th>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit or a<br \/>\nCommunication Control Unit<br \/>\n1.10 W max.<br \/>\n\u2022 Connected to a Communications Coupler<br \/>\nUnit<br \/>\n0.70 W max.<\/td>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit or a<br \/>\nCommunication Control Unit<br \/>\n1.10 W max.<br \/>\n\u2022 Connected to a Communications Coupler<br \/>\nUnit<br \/>\n0.75 W max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current consumption<br \/>\nfrom I\/O power supply<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">20 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">70 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Circuit layout<\/strong><\/th>\n<td class=\"left middle\"><img title=\"3719_sp_7_3\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_7_313-285399.gif\" alt=\"3719_sp_7_3\" \/><\/td>\n<td class=\"left middle\"><img title=\"3719_sp_7_4\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_7_413-285400.gif\" alt=\"3719_sp_7_4\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Terminal connection<br \/>\ndiagram<\/strong><\/th>\n<td class=\"left middle\">Si0 to Si3: Safety input terminals<br \/>\nT0 and T1: Test output terminals<br \/>\n<img title=\"3719_sp_7_5\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_7_513-285401.gif\" alt=\"3719_sp_7_5\" \/><br \/>\nRefer to User&#8217;s manual (Cat. No. Z395) for<br \/>\ndetails.<\/td>\n<td class=\"left middle\">Si0 to Si7: Safety input terminals<br \/>\nT0 and T1: Test output terminals<br \/>\n<img title=\"3719_sp_7_6\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_7_613-285402.gif\" alt=\"3719_sp_7_6\" \/><br \/>\nRefer to User&#8217;s manual (Cat. No. Z395) for<br \/>\ndetails.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation orientation<br \/>\nand restrictions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Installation orientation:<br \/>\n\u2022 Connected to a CPU Unit or a Communication Control Unit *<br \/>\nPossible in the upright installation orientation.<br \/>\n\u2022 Connected to a Communications Coupler Unit<br \/>\n6 possible orientations.<br \/>\nRestrictions: Maximum ambient temperature is 50\u00b0C for any orientation other than<br \/>\nupright installation.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Protective functions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Overvoltage protection circuit and short detection (test outputs)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Only NX102 CPU Units and Communication Control Units can be connected. NX1P2 CPU Units cannot be connected.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Safety Output Units NX-SOH200\/SOD400<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>Unit name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Safety Output Unit<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">NX-SOH200<\/td>\n<td class=\"left middle\">NX-SOD400<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of safety output<br \/>\npoints<\/strong><\/th>\n<td class=\"left middle\">2 points<\/td>\n<td class=\"left middle\">4 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Internal I\/O common<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">PNP (sourcing outputs)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum load current<\/strong><\/th>\n<td class=\"left middle\">2.0 A\/point<br \/>\n4.0 A\/Unit at 40\u00b0C<br \/>\n2.5 A\/Unit at 55\u00b0C<br \/>\nThe maximum load current depends on the<br \/>\ninstallation orientation and ambient<br \/>\ntemperature<\/td>\n<td class=\"left middle\">0.5 A\/point and 2.0 A\/Unit<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Rated voltage<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">24 VDC (20.4 to 28.8 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of safety slave<br \/>\nconnections<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O refreshing method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Free-Run refreshing<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>External connection<br \/>\nterminals<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Screwless clamping terminal block (8 terminals)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Indicators<\/strong><\/th>\n<td class=\"left middle\">[TS] indicator, [FS] indicator, [OUT] indicator,<br \/>\n[OUT ERR] indicator<br \/>\n<img title=\"3719_sp_8_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_8_113-285403.gif\" alt=\"3719_sp_8_1\" \/><\/td>\n<td class=\"left middle\">[TS] indicator, [FS] indicator, [OUT] indicator,<br \/>\n[OUT ERR] indicator<br \/>\n<img title=\"3719_sp_8_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_8_213-285404.gif\" alt=\"3719_sp_8_2\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Safety output ON<br \/>\nesidual voltage<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">1.2 V max. (Between IOV and all output terminals)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Safety output OFF<br \/>\nresidual voltage<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">2 V max. (Between IOG and all output terminals)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Safety output leakage<br \/>\ncurrent<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">0.1 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">12 \u00d7 100 \u00d7 71 mm (W \u00d7 H \u00d7 D)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Photocoupler isolation<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation resistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">20 M\u03a9\u00a0min. between isolated circuits (at 100 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dielectric strength<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">510 VAC for 1 min between isolated circuits, leakage current: 5 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O power supply<br \/>\nmethod<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Power supplied from the NX bus<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current capacity of I\/O<br \/>\npower supply terminals<\/strong><\/th>\n<td class=\"left middle\">IOG: 2 A max.\/terminal<\/td>\n<td class=\"left middle\">IOG (A3 and B3): 2 A max.\/terminal<br \/>\nIOG (A7 and B7): 0.5 A max.\/terminal<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power<br \/>\nconsumption<\/strong><\/th>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit or a<br \/>\nCommunication Control Unit<br \/>\n1.05 W max.<br \/>\n\u2022 Connected to a Communications Coupler<br \/>\nUnit<br \/>\n0.70 W max.<\/td>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit or a<br \/>\nCommunication Control Unit<br \/>\n1.10 W max.<br \/>\n\u2022 Connected to a Communications Coupler<br \/>\nUnit<br \/>\n0.75 W max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current consumption<br \/>\nfrom I\/O power supply<\/strong><\/th>\n<td class=\"left middle\">40 mA max.<\/td>\n<td class=\"left middle\">60 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">65 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Circuit layout<\/strong><\/th>\n<td class=\"left middle\"><img title=\"3719_sp_8_3\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_8_313-285405.gif\" alt=\"3719_sp_8_3\" \/><\/td>\n<td class=\"left middle\"><img title=\"3719_sp_8_4\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_8_413-285406.gif\" alt=\"3719_sp_8_4\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Terminal connection<br \/>\ndiagram<\/strong><\/th>\n<td class=\"left middle\">So0 and So1: Safety output terminals<br \/>\nIOG: I\/O power supply 0 V<br \/>\n<img title=\"3719_sp_8_5\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_8_513-285407.gif\" alt=\"3719_sp_8_5\" \/><br \/>\nRefer to User&#8217;s manual (Cat. No. Z395) for<br \/>\ndetails.<\/td>\n<td class=\"left middle\">So0 to So3: Safety output terminals<br \/>\nIOG: I\/O power supply 0 V<br \/>\n<img title=\"3719_sp_8_6\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_8_613-285408.gif\" alt=\"3719_sp_8_6\" \/><br \/>\nRefer to User&#8217;s manual (Cat. No. Z395) for<br \/>\ndetails.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation orientation<br \/>\nand restrictions<\/strong><\/th>\n<td class=\"left middle\">Installation orientation:<br \/>\n\u2022 Connected to a CPU Unit or a<br \/>\nCommunication Control Unit *<br \/>\nPossible in the upright installation<br \/>\norientation.<br \/>\n\u2022 Connected to a Communications Coupler<br \/>\nUnit<br \/>\n6 possible orientations<br \/>\nRestrictions:<br \/>\nFor upright installation, the ambient<br \/>\ntemperature is restricted as shown below<br \/>\ndepending on the total Unit load current.<br \/>\n<img title=\"3719_sp_8_7\" src=\"http:\/\/www.ia.omron.com\/Images\/3719_sp_8_713-285409.gif\" alt=\"3719_sp_8_7\" \/><\/td>\n<td class=\"left top\">Installation orientation:<br \/>\n\u2022 Connected to a CPU Unit or a<br \/>\nCommunication Control Unit *<br \/>\nPossible in the upright installation<br \/>\norientation.<br \/>\n\u2022 Connected to a Communications Coupler<br \/>\nUnit<br \/>\n6 possible orientations.<br \/>\nRestrictions: None<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Protective functions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Overvoltage protection circuit and short detection (test outputs)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Only NX102 CPU Units and Communication Control Units can be connected. NX1P2 CPU Units cannot be connected.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Function Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Refer to your local OMRON website for function specifications of the Communication Control Unit and Safety Control Unit.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Version Information<\/h4>\n<h4 class=\"heading-A02\">Relationship between the Unit Versions of Safety Control Units and Sysmac Studio Versions<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>This section describes the combinations that can be used of the unit versions of the Safety Control Unit and the Communication Control Unit, and the version of the Sysmac Studio.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Safety Control Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Corresponding unit version\/version<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Communication Control Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Studio<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-SL5500<\/td>\n<td class=\"center middle\">Ver. 1.3<\/td>\n<td class=\"center middle\">Ver. 1.01<\/td>\n<td class=\"center middle\">Ver. 1.24 *1<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-SL5700<\/td>\n<td class=\"center middle\">Ver. 1.3<\/td>\n<td class=\"center middle\">Ver. 1.01<\/td>\n<td class=\"center middle\">Ver. 1.24 *1<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-SIH400<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<td class=\"center middle\">Ver. 1.00<\/td>\n<td class=\"center middle\">Ver. 1.24 *2<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-SIH400<\/td>\n<td class=\"center middle\">Ver. 1.1<\/td>\n<td class=\"center middle\">Ver. 1.00<\/td>\n<td class=\"center middle\">Ver. 1.24 *2<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-SID800<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<td class=\"center middle\">Ver. 1.00<\/td>\n<td class=\"center middle\">Ver. 1.24 *2<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-SOD400<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<td class=\"center middle\">Ver. 1.00<\/td>\n<td class=\"center middle\">Ver. 1.24 *2<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-SOH200<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<td class=\"center middle\">Ver. 1.00<\/td>\n<td class=\"center middle\">Ver. 1.24 *2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. The data types in the following table are supported for communications between NX Units.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01 set-width\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Supported data types<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"center middle\">BOOL<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">BYTE<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">INT<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">WORD<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">DINT<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*2. Communications between NX Units are not supported.<\/p>\n<\/div>\n<\/div>\n<p class=\"date-line\">last update: August 20, 2018<\/p>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Communication Control Unit<\/h4>\n<h4 class=\"heading-B02\">NX-CSG320<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_dm_113-285410.gif\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Dimensions 2 \" \/><\/div>\n<div class=\"text\">\n<p>Note: For dimensions with the communications cable connected, refer to NX-series User&#8217;s Manual Safety Control Unit\/Communication Control Unit (Cat. No.Z395)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Safety Control Units<\/h4>\n<h4 class=\"heading-B02\">Safety CPU Units NX-SL5500\/SL5700<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_dm_213-285411.gif\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Dimensions 4 \" \/><\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Safety Input Units NX-SIH400\/SID800<br \/>\nSafety Output Units NX-SOH200\/SOD400<\/strong><\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_dm_313-285412.gif\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Dimensions 5 \" \/><\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. The dimension is 1.35 mm for Units with lot numbers through December 2014.<br \/>\n*2. The dimension from the attachment surface of the DIN Track to the front surface of the Safety I\/O Unit.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">End Cover NX-END02<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_dm_413-285413.gif\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Dimensions 7 \" \/><\/div>\n<div class=\"text\">\n<p>* The dimension from the attachment surface of the DIN<br \/>\nTrack to the front surface of the end cover.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">SD Memory Card HMC-SD291\/SD491<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3719_dm_513-285414.gif\" alt=\"NX-CSG \/ SL5 \/ SI \/ SO Dimensions 8 \" \/><\/div>\n<\/div>\n<\/div>\n<div>\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/nx_series_f104-e1_1_5_csm1065342.pdf?id=3719\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-Series Safety NetworkController Cataolg<\/a><\/td>\n<td>F104-E1-03<br \/>\n<span class=\"file-size\">[9815KB]<\/span><\/td>\n<td class=\"td_date\">Dec 14, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">Quick, easy, and flexible to integrate safety into production lines<\/h2>\n","protected":false},"featured_media":1366,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[97,63,72],"product_tag":[],"_links":{"self":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product\/1365"}],"collection":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/comments?post=1365"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media\/1366"}],"wp:attachment":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media?parent=1365"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1365"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1365"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}