{"id":1357,"date":"2019-01-02T01:31:42","date_gmt":"2019-01-02T01:31:42","guid":{"rendered":"http:\/\/store.al-tet.com\/?post_type=product&#038;p=1357"},"modified":"2019-01-02T01:31:43","modified_gmt":"2019-01-02T01:31:43","slug":"nx-ilm400","status":"publish","type":"product","link":"http:\/\/store.al-tet.com\/index.php\/product\/nx-ilm400\/","title":{"rendered":"NX-ILM400"},"content":{"rendered":"<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Downtime can be reduced.<\/strong><\/p>\n<p>Notifies you of faulty parts and such phenomena in the Sensor in real time.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>The frequency of sudden failure can be decreased.<\/strong><\/p>\n<p>Condition monitoring of sensors and equipment to prevent troubles.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>The efficiency of changeover can be improved.<\/strong><\/p>\n<p>The batch check for individual sensor IDs significantly decreases commissioning time.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">[To those in charge of maintenance \u201cCondition monitoring\u201d for predictive maintenance (1)] Reduction of Sudden Stops by Grasping the Flow Rate Simultaneously with the Temperature of Cooling Water and Hydraulic Oil Circulating in Equipment<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_113-263881.jpg\" alt=\"NX-ILM400 Features 4 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Existing problems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>While the presence or absence of cooling water is checked by means of the ON\/OFF-based pressure sensor, it is unable to detect any drop in the flow rate of the cooling water or any rise in the cooling water temperature. For that reason,<\/p>\n<p>\u2219 The transformer is not cooled, and gets overheated, potentially leading to sudden stops of the equipment and the entire line.<\/p>\n<p>\u2219 The tip may be deformed, causing defective products.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_213-263882.jpg\" alt=\"NX-ILM400 Features 5 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">With an IO-Link IoT Flow Sensor<\/h4>\n<h4 class=\"heading-B02\">The flow rate and simultaneously the temperature of the circulation system are measured, substantially reducing sudden error.<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Simultaneous monitoring of the flow rate and temperature changes, and informing of those changes, enable you to carry out predictive maintenance and reduce defective products.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_313-263883.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_3-13-263883-332x334.jpg\" alt=\"NX-ILM400 Features 7 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_313-263883.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">[To those in charge of maintenance \u201cCondition monitoring\u201d for predictive maintenance (2)] The Proximity Sensor Indicates an Excessive Proximity to the Sensing Object. Understand the Changes in Equipment Condition in Advance and Reduce Sudden Stops<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_113-263881.jpg\" alt=\"NX-ILM400 Features 8 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Existing problems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The detection position changes due to wear and vibration in the equipment\u2019s mechanical parts and as a result, false detection and collision with the sensor have a negative impact on the equipment&#8230;<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_413-263884.jpg\" alt=\"NX-ILM400 Features 9 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">With an IO-Link Proximity Sensor<\/h4>\n<h4 class=\"heading-B02\">You are notified of excessive remoteness or proximity, and the occurrence of sudden defects is greatly reduced<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Constantly monitoring the position of the sensing object and notifying of excessive remoteness or proximity can be used for predictive maintenance of the equipment.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_513-263885.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_5-13-263885-332x312.jpg\" alt=\"NX-ILM400 Features 11 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_513-263885.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">[To those in charge of maintenance \u201cCondition monitoring\u201d for predictive maintenance (3)] Understand Unstable Situations in the Incident Level of the Photoelectric Sensor in Advance and Reduce Sudden Stops<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_113-263881.jpg\" alt=\"NX-ILM400 Features 12 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Existing problems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2219 In a conveyance process operating for 24 hours, dust or dirt accumulated on the detection surface of the photoelectric sensor, leading to a decline in the light incident level that causes the sensor to make false detection and the equipment to stop&#8230;<\/p>\n<p>\u2219 Water drops stick to the sensing surface of the reflective sensor causing reflected light to enter&#8230;<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_613-263886.jpg\" alt=\"NX-ILM400 Features 13 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">With an IO-Link Photoelectric Sensor<\/h4>\n<h4 class=\"heading-B02\">A light incident level monitor prevents false detection<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>With a response time of 1 ms, Photoelectric Sensor\u2019s light incident level is output for monitoring. It is output when the light incident level exceeds the instability detection threshold, so you can check the site before false detection occurs and perform predictive maintenance.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_713-263887.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_7-13-263887-332x262.jpg\" alt=\"NX-ILM400 Features 15 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_713-263887.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">[To those in charge of maintenance \u201cAbnormality detection\u201d for the shortest recovery] Detects Wiring Cable Disconnections and Errors and Improves Equipment Operation Rate Through Quick Maintenance<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_813-263888.jpg\" alt=\"NX-ILM400 Features 16 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Existing problems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2219 An abnormality was displayed on the abnormality display screen, but upon going to look at the equipment, no external error was detected and the cause of the stop was not understood&#8230;<\/p>\n<p>\u2219 Those responsible for maintenance investigated the cause of the abnormality from the activity of the stopped equipment, but because the maintenance person relied on the skill he or she has to identify the abnormality and replace the failed sensor, stoppages from 2 hours to several days occur&#8230;<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_913-263889.jpg\" alt=\"NX-ILM400 Features 17 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">With an IO-Link Sensor<\/h4>\n<h4 class=\"heading-B02\">Abnormal area and phenomenon of sensors are reported in real time<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>When an abnormality occurs in a sensor, because you can see where the abnormality occurred and the factors estimated for it, you can go to where the abnormality occurred and recover the equipment in the shortest amount of time.<br \/>\nAlso with wire disconnection detection, not only output wires, but also power lines can be detected unconditionally.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1013-263890.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_10-13-263890-332x159.jpg\" alt=\"NX-ILM400 Features 19 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1013-263890.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Easy replacement of IO-Link sensors with Non-IO-Link sensors<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>You need a quick recovery but you have only Non-IO-Link sensors with no IO-Link sensors in stock. You probably think in such a case, the control program needs modifications, and requires additional time for the recovery.<br \/>\nWith IO-Link Master, since the IO-Link ON\/OFF data and the data for Non-IO-Link sensors are located in the same memory, replacement with Non-IO-Link sensors can be carried out without any modification of the control program, resulting in a reduction of the equipment downtime.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1113-263891.jpg\" alt=\"NX-ILM400 Features 20 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A01\">[To those in charge of production engineering \u201cIndividual identification\u201d for the reduction of man-hours] Improving System Commissioning and Changeover Efficiency by Checking Identifications in Batches<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1613-285168.jpg\" alt=\"NX-ILM400 Features 21 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Existing problems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2219 During system start-up or changeover, operators had to perform the I\/O check for each of the thousands of sensors installed on the line, and it took an enormous amount of time&#8230;<\/p>\n<p>\u2219 When a sensor is installed wrong or an error occurs, wasteful work occurred that would normally be unnecessary&#8230;<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1213-263892.jpg\" alt=\"NX-ILM400 Features 22 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">With an IO-Link Sensor<\/h4>\n<h4 class=\"heading-B02\">Without going to the site, you can check individual sensor identifications in batches, resulting in a sharp reduction of commissioning time<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>By checking the sensor identification (manufacturer\/sensor type\/model number), you can easily check mistakes such as misconnected or unconnected sensors and installation mistakes.<br \/>\nAlso, because it is possible to program multiple sensors at once using the command language used only for the controller, it is also possible to reduce commissioning time sharply.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1313-263893.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_13-13-263893-332x260.jpg\" alt=\"NX-ILM400 Features 24 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1313-263893.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">[Omron\u2019s IO-Link Compliant Equipment] Masters and Sensors Can Be Chosen to Match Your Situation<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>For the connection of IO-Link Sensors and IO-Link Masters, two types are available: a screw-less clamp terminal block and an M12 connector.<br \/>\nIn addition, NX-ILM400 IO-Link Master with screw-less clamp terminal block is connectable not only to EtherCAT, but also to EtherNet\/IP communication coupler units, and you can choose between them according to the system configuration.<\/p>\n<\/div>\n<div class=\"image\"><a href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1413-263894.jpg\" target=\"_blank\" rel=\"noopener\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_14-13-263894-332x376.jpg\" alt=\"NX-ILM400 Features 25 \" \/><\/a><\/p>\n<div class=\"img_caption\"><a class=\"link_list blank_link\" href=\"http:\/\/www.ia.omron.com\/Images\/3540_fe_1413-263894.jpg\" target=\"_blank\" rel=\"noopener\">Please click image to enlarge (open in a new window).<\/a><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">IO-Link makes sensor level information visible and solves the three major issues at manufacturing sites! The screwless clamping terminal block reduces wiring work.<\/h2>\n","protected":false},"featured_media":1358,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[97,63,72],"product_tag":[],"_links":{"self":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product\/1357"}],"collection":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/comments?post=1357"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media\/1358"}],"wp:attachment":[{"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/media?parent=1357"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1357"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/store.al-tet.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1357"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}